Development of an inconel self powered neutron detector for in-core reactor monitoring

被引:11
|
作者
Alex, M. [1 ]
Ghodgaonkar, M. D. [1 ]
机构
[1] BARC, Div Elect, Bombay, Maharashtra, India
关键词
self powered; neutron detector; in-core; inconel;
D O I
10.1016/j.nima.2007.01.084
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper describes the development and testing of an Incone1600 (2 mm diameter x 21 cm long) self-powered neutron detector for in-core neutron monitoring. The detector has 3.5 mm overall diameter and 22 cm length and is integrally coupled to a 12 m long mineral insulated cable. The performance of the detector was compared with cobalt and platinum detectors of similar dimensions. Gamma sensitivity measurements performed at the (CO)-C-60 irradiation facility in 14 MR/h gamma field showed values of -4.4 x 10(-18) A/R/h/cm (-9.3 x 10(-24) A/gamma/cm(2)-s/cm), -5.2 x 10(-18) A/R/h/cm (- 1.133 x 10(-23) A/gamma/cm(2)-s/cm) and 34 x 10(-18) A/R/h/cm (7.14 x 10(-23) A/gamma/cm(2)-s/cm) for the Inconel, Co and Pt detectors, respectively. The detectors together with a miniature gamma ion chamber and fission chamber were tested in the in-core Apsara Swimming Pool type reactor. The ion chambers were used to estimate the neutron and gamma fields. With an effective neutron cross-section of 4b, the Inconel detector has a total sensitivity of 6 x 10(-23) A/nv/cm while the corresponding sensitivities for the platinum and cobalt detectors were 1.69 x 10(-22) and 2.64 x 10(-22) A/nv/cm. The linearity of the detector responses at power levels ranging from 100 to 200 kW was within +/- 5 %. The response of the detectors to reactor scram showed that the prompt response of the Inconel detector was 0.95 while it was 0.7 and 0.95 for the platinum and cobalt self-powered detectors, respectively. The detector was also installed in the horizontal flux unit of 540 MW Pressurised Heavy Water Reactor (PHWR). The neutron flux at the detector location was calculated by Triveni code. The detector response was measured from 0.02% to 0.07% of full power and showed good correlation between power level and detector signals. Long-term tests and the dynamic response of the detector to shut down in PHWR are in progress. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 50 条
  • [1] DEVELOPMENT AND IN-CORE APPLICATION OF SELF-POWERED NEUTRON DETECTORS.
    Gebureck, P.
    Hofmann, W.
    Jaschik, W.
    Seifritz, W.
    Stegemann, D.
    1973, : 783 - 802
  • [2] AN IN-CORE RADIATION DETECTOR FOR MONITORING PULSED REACTOR EXCURSIONS
    TODT, WH
    NUCLEAR APPLICATIONS, 1968, 5 (03): : 173 - &
  • [3] IN-CORE RADIATION DETECTOR FOR MONITORING PULSED REACTOR EXCURSIONS
    TODT, WH
    JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1969, 8 (04): : 320 - &
  • [4] Lifetime extension of in-core self-powered neutron detector using new emitter materials
    Kong, Chidong
    Lee, Deokjung
    Shin, Ho Cheol
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2017, 41 (14) : 2405 - 2412
  • [5] IN-CORE, SELF-POWERED FAST NEUTRON FLUX MONITORS
    UPTON, JW
    BROWN, DP
    SPEAR, WG
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, : 14 - &
  • [6] IN-CORE NEUTRON-DETECTOR BEHAVIOR DURING REACTOR TRANSIENT OPERATION
    BOCK, H
    NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (02): : 327 - 329
  • [7] TRENDS IN INSTRUMENT DEVELOPMENT FOR REACTOR IN-CORE FLUX MONITORING
    KROON, JC
    GLESIUS, FL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 786 - 790
  • [8] Measurement method of in-core neutron and gamma-ray distributions with scintillator optical fibre detector and self-powered detector
    Mori, C
    Uritani, A
    Kakuta, T
    Katagiri, M
    Shikama, T
    Nakazawa, M
    Iguchi, T
    Kawarabayashi, J
    Kimura, I
    Kobayashi, H
    Hayashi, S
    BASIC STUDIES IN THE FIELD OF HIGH-TEMPERATURE ENGINEERING, 2002, : 161 - 166
  • [9] USING A SELF-POWERED PLATINUM FLUX DETECTOR FOR IN-CORE MEASUREMENTS IN A BWR
    SEIFRITZ, W
    GEBURECK, P
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1973, 17 (NOV): : 449 - 450
  • [10] Research on Key Parameters of Self-Powered Neutron Detector of In-core Neutron Fluence Rate Measurement System in HPR1000
    Huang Y.
    Li W.
    Yang D.
    Jiang T.
    Wang Y.
    Yu H.
    Lin C.
    Zhang Y.
    Hedongli Gongcheng/Nuclear Power Engineering, 2020, 41 : 45 - 49