Development of an inconel self powered neutron detector for in-core reactor monitoring

被引:11
|
作者
Alex, M. [1 ]
Ghodgaonkar, M. D. [1 ]
机构
[1] BARC, Div Elect, Bombay, Maharashtra, India
关键词
self powered; neutron detector; in-core; inconel;
D O I
10.1016/j.nima.2007.01.084
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper describes the development and testing of an Incone1600 (2 mm diameter x 21 cm long) self-powered neutron detector for in-core neutron monitoring. The detector has 3.5 mm overall diameter and 22 cm length and is integrally coupled to a 12 m long mineral insulated cable. The performance of the detector was compared with cobalt and platinum detectors of similar dimensions. Gamma sensitivity measurements performed at the (CO)-C-60 irradiation facility in 14 MR/h gamma field showed values of -4.4 x 10(-18) A/R/h/cm (-9.3 x 10(-24) A/gamma/cm(2)-s/cm), -5.2 x 10(-18) A/R/h/cm (- 1.133 x 10(-23) A/gamma/cm(2)-s/cm) and 34 x 10(-18) A/R/h/cm (7.14 x 10(-23) A/gamma/cm(2)-s/cm) for the Inconel, Co and Pt detectors, respectively. The detectors together with a miniature gamma ion chamber and fission chamber were tested in the in-core Apsara Swimming Pool type reactor. The ion chambers were used to estimate the neutron and gamma fields. With an effective neutron cross-section of 4b, the Inconel detector has a total sensitivity of 6 x 10(-23) A/nv/cm while the corresponding sensitivities for the platinum and cobalt detectors were 1.69 x 10(-22) and 2.64 x 10(-22) A/nv/cm. The linearity of the detector responses at power levels ranging from 100 to 200 kW was within +/- 5 %. The response of the detectors to reactor scram showed that the prompt response of the Inconel detector was 0.95 while it was 0.7 and 0.95 for the platinum and cobalt self-powered detectors, respectively. The detector was also installed in the horizontal flux unit of 540 MW Pressurised Heavy Water Reactor (PHWR). The neutron flux at the detector location was calculated by Triveni code. The detector response was measured from 0.02% to 0.07% of full power and showed good correlation between power level and detector signals. Long-term tests and the dynamic response of the detector to shut down in PHWR are in progress. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:127 / 132
页数:6
相关论文
共 50 条
  • [21] DEVELOPMENT OF A DIRECTIONAL GAMMA-RAY DETECTOR FOR IN-CORE FUEL MOTION MONITORING
    COX, SA
    BEYERLEIN, RA
    LEVERT, FE
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 263 - 265
  • [22] Pulse-reactor core monitoring with an innovative optical neutron detector
    Lamotte, M.
    De Izarra, G.
    Jammes, C.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 995
  • [23] SELF-POWERED NEUTRON DETECTOR TESTING IN BIG ROCK POINT REACTOR
    WORSHAM, HJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1970, 13 (01): : 236 - &
  • [24] Development of in-core monitoring system using optical fiber for advanced fission reactor
    Kakuta, T
    Ishihara, M
    Shikama, T
    Narui, M
    Sagawa, T
    Arai, T
    Hayashi, K
    REACTOR DOSIMETRY: RADIATION METROLOGY AND ASSESSMENT, 2001, 1398 : 797 - 802
  • [25] REACTOR POWER DISTRIBUTION FROM ANALYSIS OF IN-CORE DETECTOR READINGS
    LEVINE, MM
    DIAMOND, DJ
    NUCLEAR SCIENCE AND ENGINEERING, 1972, 47 (04) : 415 - &
  • [26] NEUTRON NOISE MONITORING OF IN-CORE VIBRATIONS ON CHINAS HIGH-FLUX ENGINEERING TEST REACTOR
    ZHANG, MC
    ZHAO, YY
    SHEN, DG
    PROGRESS IN NUCLEAR ENERGY, 1985, 15 (1-3) : 313 - 321
  • [27] MODELING THE LOCAL COMPONENT OF IN-CORE NEUTRON DETECTOR NOISE IN A BWR
    SWEENEY, FJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 33 (NOV): : 854 - 855
  • [28] IN-CORE NEUTRON DETECTOR RESPONSE MODEL BASED ON BASIC PRINCIPLES
    HANNAMAN, GW
    DANOFSKY, RA
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1975, 21 (JUN): : 479 - 480
  • [29] In-Core Neutron Measurement using SiC Detector for Fast Response
    Park, Junesic
    Park, Se Hwan
    Son, Jaebum
    Kim, Yong Kyun
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [30] A new system for in-core wide range neutron monitoring
    Lescop, B
    Normand, S
    Trama, JC
    Laribière, L
    Nguyen, T
    Souloumiac, A
    Delacour, P
    Blandin, C
    Cantonnet, B
    Pasdeloup, P
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 1567 - 1570