Binary Zn-Ti alloys for orthopedic applications: Corrosion and degradation behaviors, friction and wear performance, and cytotoxicity

被引:63
|
作者
Wang, Kun [1 ,2 ]
Tong, Xian [1 ,3 ]
Lin, Jixing [1 ]
Wei, Aiping [1 ]
Li, Yuncang [4 ]
Dargusch, Matthew [5 ]
Wen, Cuie [4 ]
机构
[1] Zhejiang Ind & Trade Vocat Coll, Dept Mat Engn, Wenzhou 325003, Peoples R China
[2] Chinese Acad Sci Heifei, Inst Solid State Phys, Key Lab Mat Phys, Hefei 230031, Peoples R China
[3] Xiangtan Univ, Sch Mat Sci & Engn, Xiangtan 411105, Peoples R China
[4] RMIT Univ, Sch Engn, Melbourne, Vic 3001, Australia
[5] Univ Queensland, Ctr Adv Mat Proc & Mfg AMPAM, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
Cytotoxicity; Degradation behavior; Mechanical property; Wear resistance; Zn-Ti alloy; MECHANICAL-PROPERTIES; IN-VITRO; TITANIUM; ZINC; MG; DESIGN; MICROSTRUCTURE; ELEMENTS; SCREWS; PHASE;
D O I
10.1016/j.jmst.2020.10.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Zinc (Zn) and its biocompatible and biodegradable alloys have substantial potential for use in orthopedic implants. Nevertheless, pure Zn with a hexagonal close-packed crystal structure has only two independent slip systems, therefore exhibiting extremely low elongation and yield strength in its as-cast condition, which restricts its clinical applications. In this study, as-cast Zn-xTi (titanium) (x = 0.05, 0.10, 0.20, and 0.30 wt.%) binary alloys were hot-rolled and their microstructures, mechanical properties, wear resistance, and cytocompatibility were comprehensively investigated for orthopedic implant applications. The microstructures of both as-cast and hot-rolled Zn-xTi alloys consisted of an alpha-Zn matrix phase and a TiZn16 phase, while Zn-0.2Ti and Zn-0.3Ti exhibited a finer alpha-Zn phase due to the grain-refining effect of Ti. The hot-rolled Zn-0.2Ti alloy exhibited the highest yield strength (144.5 MPa), ultimate strength (218.7 MPa), and elongation (54.2%) among all the Zn-xTi alloys. The corrosion resistance of Zn-xTi alloys in Hanks' solution decreased with increasing addition of Ti, and the hot-rolled Zn-0.3Ti alloy exhibited the highest corrosion rates of 432 mu m/y as measured by electrochemical testing and 57.9 mu m/y as measured by immersion testing. The as-cast Zn-xTi alloys showed lower wear losses than their hot-rolled counterparts. The extracts of hot-rolled Zn-xTi alloys at concentrations of <= 25% showed no cytotoxicity to MG-63 osteosarcoma cells and the extracts of Zn-xTi alloys exhibited enhanced cytocompatibility with increasing Ti content. (C) 2021 Published by Elsevier Ltd on behalf of The editorial office of Journal of Materials Science & Technology.
引用
收藏
页码:216 / 229
页数:14
相关论文
共 50 条
  • [21] Biodegradable Zn-3Cu and Zn-3Cu-0.2Ti alloys with ultrahigh ductility and antibacterial ability for orthopedic applications
    Lin, Jixing
    Tong, Xian
    Wang, Kun
    Shi, Zimu
    Li, Yuncang
    Dargusch, Matthew
    Wen, Cuie
    JOURNAL OF MATERIALS SCIENCE & TECHNOLOGY, 2021, 68 : 76 - 90
  • [22] Dry Sliding Wear and Corrosion Performance of Mg-Sn-Ti Alloys Produced by Casting and Extrusion
    Bovand, Davoud
    Abdollah-Pour, Hassan
    Mirzaee, Omid
    Bagherifard, Sara
    MATERIALS, 2022, 15 (10)
  • [23] Controlling the Degradation Rate of Biodegradable Mg-Zn-Mn Alloys for Orthopedic Applications by Electrophoretic Deposition of Hydroxyapatite Coating
    Antoniac, Iulian
    Miculescu, Florin
    Cotrut, Cosmin
    Ficai, Anton
    Rau, Julietta V.
    Grosu, Elena
    Antoniac, Aurora
    Tecu, Camelia
    Cristescu, Ioan
    MATERIALS, 2020, 13 (02)
  • [24] Composition design and performance analysis of binary and ternary Mg-Zn-Ti alloys for biomedical implants
    Mukhtar, Sehrish
    Kamran, Muhammad
    Tayyeb, Asima
    Hussain, Faraz
    Ishtiaq, Muhammad
    Riaz, Fahad
    Asghar, Waqas
    JOURNAL OF BIOLOGICAL PHYSICS, 2025, 51 (01)
  • [25] Biodegradable Mg-3Zn Alloy/Titanium-Hydroxyapatite Hybrid Composites: Corrosion and Cytotoxicity Evaluation for Orthopedic Implant Applications
    Vignesh, P.
    Ramanathan, S.
    Ashokkumar, M.
    Ananthi, V.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2024, 77 (06) : 1701 - 1710
  • [26] Precipitation and intergranular corrosion behaviors of Al-Mg-Si-Cu-(2.0%Zn) alloys for automotive applications
    Han S.-J.
    Yan Y.
    Guo M.-X.
    Feng W.-J.
    Li M.-M.
    Zhuang L.-Z.
    Zhang J.-S.
    Zhongguo Youse Jinshu Xuebao/Chinese Journal of Nonferrous Metals, 2022, 32 (08): : 2198 - 2208
  • [27] Composition design and performance analysis of binary and ternary Mg-Zn-Ti alloys for biomedical implantsComposition design and performance analysis of binary and ternary Mg-Zn-Ti alloys for biomedical implantsS. Mukhtar et al.
    Sehrish Mukhtar
    Muhammad Kamran
    Asima Tayyeb
    Faraz Hussain
    Muhammad Ishtiaq
    Fahad Riaz
    Waqas Asghar
    Journal of Biological Physics, 2025, 51 (1)
  • [28] In Vitro Corrosion Performance of As-Extruded Mg-Gd-Dy-Zr Alloys for Potential Orthopedic Applications
    Liu, Chen
    Wang, Junsheng
    Xu, Yongdong
    Fu, Yu
    Han, Jungang
    Cao, Zhaoxun
    Chen, Xiaohu
    Zhao, Shuming
    Zhu, Xiurong
    METALS, 2022, 12 (04)
  • [29] Impact of copper on corrosion behavior, biocompatibility and antibaterial activity of biodegradable Zn-3Mg-xCu alloys for orthopedic applications
    Wei, Zhangli
    Zhang, Xingyan
    Li, Jingyi
    Shi, Wenling
    Xie, Fengbao
    Wang, Gang
    Li, Hongxia
    Chao, Pan
    MATERIALS RESEARCH EXPRESS, 2023, 10 (09)
  • [30] Biodegradable Zn–3Cu and Zn–3Cu–0.2Ti alloys with ultrahigh ductility and antibacterial ability for orthopedic applications
    Jixing Lin
    Xian Tong
    Kun Wang
    Zimu Shi
    Yuncang Li
    Matthew Dargusch
    Cuie Wen
    Journal of Materials Science & Technology, 2021, 68 (09) : 76 - 90