Binary Zn-Ti alloys for orthopedic applications: Corrosion and degradation behaviors, friction and wear performance, and cytotoxicity

被引:63
|
作者
Wang, Kun [1 ,2 ]
Tong, Xian [1 ,3 ]
Lin, Jixing [1 ]
Wei, Aiping [1 ]
Li, Yuncang [4 ]
Dargusch, Matthew [5 ]
Wen, Cuie [4 ]
机构
[1] Zhejiang Ind & Trade Vocat Coll, Dept Mat Engn, Wenzhou 325003, Peoples R China
[2] Chinese Acad Sci Heifei, Inst Solid State Phys, Key Lab Mat Phys, Hefei 230031, Peoples R China
[3] Xiangtan Univ, Sch Mat Sci & Engn, Xiangtan 411105, Peoples R China
[4] RMIT Univ, Sch Engn, Melbourne, Vic 3001, Australia
[5] Univ Queensland, Ctr Adv Mat Proc & Mfg AMPAM, Brisbane, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
Cytotoxicity; Degradation behavior; Mechanical property; Wear resistance; Zn-Ti alloy; MECHANICAL-PROPERTIES; IN-VITRO; TITANIUM; ZINC; MG; DESIGN; MICROSTRUCTURE; ELEMENTS; SCREWS; PHASE;
D O I
10.1016/j.jmst.2020.10.031
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Zinc (Zn) and its biocompatible and biodegradable alloys have substantial potential for use in orthopedic implants. Nevertheless, pure Zn with a hexagonal close-packed crystal structure has only two independent slip systems, therefore exhibiting extremely low elongation and yield strength in its as-cast condition, which restricts its clinical applications. In this study, as-cast Zn-xTi (titanium) (x = 0.05, 0.10, 0.20, and 0.30 wt.%) binary alloys were hot-rolled and their microstructures, mechanical properties, wear resistance, and cytocompatibility were comprehensively investigated for orthopedic implant applications. The microstructures of both as-cast and hot-rolled Zn-xTi alloys consisted of an alpha-Zn matrix phase and a TiZn16 phase, while Zn-0.2Ti and Zn-0.3Ti exhibited a finer alpha-Zn phase due to the grain-refining effect of Ti. The hot-rolled Zn-0.2Ti alloy exhibited the highest yield strength (144.5 MPa), ultimate strength (218.7 MPa), and elongation (54.2%) among all the Zn-xTi alloys. The corrosion resistance of Zn-xTi alloys in Hanks' solution decreased with increasing addition of Ti, and the hot-rolled Zn-0.3Ti alloy exhibited the highest corrosion rates of 432 mu m/y as measured by electrochemical testing and 57.9 mu m/y as measured by immersion testing. The as-cast Zn-xTi alloys showed lower wear losses than their hot-rolled counterparts. The extracts of hot-rolled Zn-xTi alloys at concentrations of <= 25% showed no cytotoxicity to MG-63 osteosarcoma cells and the extracts of Zn-xTi alloys exhibited enhanced cytocompatibility with increasing Ti content. (C) 2021 Published by Elsevier Ltd on behalf of The editorial office of Journal of Materials Science & Technology.
引用
收藏
页码:216 / 229
页数:14
相关论文
共 50 条
  • [1] Binary Zn–Ti alloys for orthopedic applications: Corrosion and degradation behaviors, friction and wear performance, and cytotoxicity
    Kun Wang
    Xian Tong
    Jixing Lin
    Aiping Wei
    Yuncang Li
    Matthew Dargusch
    Cuie Wen
    JournalofMaterialsScience&Technology, 2021, 74 (15) : 216 - 229
  • [2] Corrosion Behavior and Mechanical Properties of Zn-Ti Alloys as Biodegradable Materials
    Sutic, Alexandra-Tamara
    Chelariu, Romeu
    Cimpoesu, Ramona
    Roman, Ana-Maria
    Istrate, Bogdan
    Goanta, Viorel
    Benchea, Marcelin
    Moscu, Mihaela
    Alexandru, Adrian
    Cimpoesu, Nicanor
    Zegan, Georgeta
    METALS, 2024, 14 (07)
  • [3] Impact of scandium on mechanical properties, corrosion behavior, friction and wear performance, and cytotoxicity of a β-type Ti-24Nb-38Zr-2Mo alloy for orthopedic applications
    Tong, Xian
    Sun, Quanxiang
    Zhang, Dechuang
    Wang, Kun
    Dai, Yilong
    Shi, Zimu
    Li, Yuncang
    Dargusch, Matthew
    Huang, Shengbin
    Ma, Jianfeng
    Wen, Cuie
    Lin, Jixing
    ACTA BIOMATERIALIA, 2021, 134 (134) : 791 - 803
  • [4] The Effect of Milling Time on Structural, Friction and Wear Behavior of Hot Isostatically Pressed Ti-Ni Alloys for Orthopedic Applications
    Fellah, Mamoun
    Hezil, Naouel
    Samad, Mohammed Abdul
    Touhami, Mohamed Zine
    Montagne, Alex
    Iost, Alain
    Mejias, Alberto
    Kossman, Stephania
    TMS 2019 148TH ANNUAL MEETING & EXHIBITION SUPPLEMENTAL PROCEEDINGS, 2019, : 865 - 875
  • [5] Corrosion and wear performance of β-Ti based biomedical shape memory alloys
    Liu, Wei
    Wang, Yunfei
    Feng, Xinxin
    Cao, Xinjian
    Liu, Xiao
    Wang, Haizhen
    Yi, Xiaoyang
    Meng, Xianglong
    Gao, Zhiyong
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2024, 42 (04):
  • [6] Wear and friction properties of experimental Ti-Si-Zr alloys for biomedical applications
    Tkachenko, Serhii
    Datskevich, Oleg
    Kulak, Leonid
    Jacobson, Staffan
    Engqvist, Hakan
    Persson, Cecilia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 39 : 61 - 72
  • [7] In Vitro Corrosion Behavior and Cytotoxicity of Polycaprolactone–Akermanite-Coated Friction-Welded Commercially Pure Ti/AZ31 for Orthopedic Applications
    Mojtaba Sadeghi Gogheri
    Masoud Kasiri-Asgarani
    Hamid Reza Bakhsheshi-Rad
    Hamid Ghayour
    Mahdi Rafiei
    Journal of Materials Engineering and Performance, 2020, 29 : 6053 - 6065
  • [8] In Vitro Corrosion Behavior and Cytotoxicity of Polycaprolactone-Akermanite-Coated Friction-Welded Commercially Pure Ti/AZ31 for Orthopedic Applications
    Gogheri, Mojtaba Sadeghi
    Kasiri-Asgarani, Masoud
    Bakhsheshi-Rad, Hamid Reza
    Ghayour, Hamid
    Rafiei, Mahdi
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2020, 29 (09) : 6053 - 6065
  • [9] In Vitro Corrosion and Bioactivity Performance of Surface-Treated Ti-20Nb-13Zr Alloys for Orthopedic Applications
    Arumugam, Madhan Kumar
    Hussein, Mohamed A.
    Adesina, Akeem Yusuf
    Al-Aqeeli, Nasser
    COATINGS, 2019, 9 (05):
  • [10] Microstructure, wear resistance, and corrosion performance of Ti35Zr28Nb alloy fabricated by powder metallurgy for orthopedic applications
    Wei Xu
    Xin Lu
    Jingjing Tian
    Chao Huang
    Miao Chen
    Yu Yan
    Luning Wang
    Xuanhui Qu
    Cuie Wen
    JournalofMaterialsScience&Technology, 2020, 41 (06) : 191 - 198