Comparative one-month safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation

被引:28
|
作者
Giordano, Arturo [1 ]
Corcione, Nicola [1 ]
Ferraro, Paolo [2 ]
Morello, Alberto [1 ]
Conte, Sirio [2 ]
Testa, Luca [3 ]
Bedogni, Francesco [3 ]
Iadanza, Alessandro [4 ]
Berti, Sergio [5 ]
Regazzoli, Damiano [6 ]
Romagnoli, Enrico [7 ]
Trani, Carlo [7 ]
Burzotta, Francesco [7 ]
Pepe, Martino [8 ]
Frati, Giacomo [9 ,10 ]
Biondi-Zoccai, Giuseppe [9 ,11 ]
Tamburino, Corrado [12 ]
Ettori, Federica [13 ]
Petronio, Anna Sonia [14 ]
Rinaldi, Mauro [15 ]
Klugmann, Silvio [16 ]
Rubino, Paolo [17 ]
Tremoli, Elena [18 ]
Marchese, Alfredo [19 ]
Sardella, Gennaro [20 ]
Pistis, Gianfranco [21 ]
Brscic, Elvis [22 ]
Giudice, Pietro [23 ]
Piatti, Luigi [24 ]
Ardissino, Diego [25 ]
Indolfi, Ciro [26 ]
Chiarella, Francesco [27 ]
Tespili, Maurizio [28 ]
De Servi, Stefano [29 ]
Bonmassari, Roberto [30 ]
Fappani, Antonio [31 ]
Cuccia, Claudio [32 ]
Cremonesi, Alberto [33 ]
Tomai, Fabrizio [34 ]
机构
[1] Pineta Grande Hosp, Unita Operat Interventist Cardiovasc, Castel Volturno, Italy
[2] Santa Lucia Hosp, Unita Operat Emodinam, San Giuseppe Vesuviano, Italy
[3] IRCCS Policlin San Donato, Dept Cardiol, Milan, Italy
[4] Policlin Santa Maria Scotte, Dipartimento Sci Cardiache Torac & Vasc, Div Emodinam, Siena, Italy
[5] Fdn CNR G Monasterio Osped Cuore, Massa, Italy
[6] Humanitas Univ, Dept Biomed Sci, Rozzano, Italy
[7] Univ Cattolica Sacro Cuore, Inst Cardiol, Fdn Policlin Univ A Gemelli IRCCS, Rome, Italy
[8] Univ Bari, Div Cardiol, Dept Emergency & Organ Transplantat, Bari, Italy
[9] Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Latina, Italy
[10] IRCCS NEUROMED, Pozzilli, Italy
[11] Mediterranea Cardioctr, Naples, Italy
[12] Univ Catania, Catania, Italy
[13] Spedali Civili Brescia, Brescia, Italy
[14] Univ Pisa, Pisa, Italy
[15] Univ Turin, Turin, Italy
[16] Osped Niguarda Ca Granda, Milan, Italy
[17] Clin Montevergine, Avellino, Italy
[18] Ctr Cardiol Monzino, Milan, Italy
[19] Anthea Hosp GVM Care & Res, Bari, Italy
[20] Sapienza Univ Rome, Policlin Umberto 1, Rome, Italy
[21] SS Antonio & Biagio & Cesare Arrigo Hosp, Alessandria, Italy
[22] Maria Pia Hosp, Turin, Italy
[23] San Giovanni di Dio & Ruggi Aragona, Salerno, Italy
[24] Osped Lecco, Lecce, Italy
[25] Azienda Osped Univ Parma, Parma, Italy
[26] Policlin Univ Mater Domini, Catanzaro, Italy
[27] IRCCS San Martino, Genoa, Italy
[28] Osped Bolognini, Seriate, Italy
[29] Osped Civile Legnano, Legnano, Italy
[30] Osped S Chiara, Trento, Italy
[31] Ist Clin San Rocco, Ome, Italy
[32] Fdn Poliambulanza, Brescia, Italy
[33] Maria Cecilia Hosp, Cotignola, Italy
[34] European Hosp, Rome, Italy
关键词
REPLACEMENT; MULTICENTER; COREVALVE; SAPIEN;
D O I
10.1038/s41598-019-53081-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transcatheter aortic valve implantation (TAVI) for aortic stenosis is becoming an appealing alternative to surgical aortic valve replacement in high-risk patients and to medical therapy for inoperable ones. Several new-generation TAVI devices have been recently introduced, but comparative analyses are lacking. We aimed to compare 1-month outcomes associated with such five leading new-generation TAVI devices exploiting data collected in the prospective observational RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) Study. We queried the dataset of the ongoing RISPEVA study to retrieve baseline, procedural and 1-month outcome details of patients undergoing TAVI with Acurate, Evolut, Portico, Lotus, and Sapien3. Analysis was based on unadjusted and propensity score-adjusted methods. We included 1976 patients, 234 (11.8%) treated with Acurate, 703 (35.6%) with Evolut, 151 (7.6%) with Lotus, 347 (17.6%) with Portico, and 541 (27.4%) with Sapien3. Unadjusted analysis for baseline features highlighted several significant differences, and other discrepancies were found for procedural features. Despite these differences, device and procedural success were similarly high (ranging from 98.0% to 99.4%, p > 0.05). However, procedural valve migration appeared more common with Acurate (p = 0.007), and major bleeding with Sapien3 (p = 0.002). Unadjusted analysis for 1-month outcomes also highlighted significant differences in the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure (favoring Portico, p < 0.001), major vascular complications (favoring Lotus, p < 0.001), renal failure (favoring Portico, p = 0.035), and permanent pacemaker implantation (favoring Acurate, p < 0.001). Propensity score-adjusted analyses showed lower rates of major adverse events with Evolut and Portico (p < 0.05), major vascular complications with Lotus and Portico (p < 0.05), renal failure with Sapien3 (p < 0.05) and permanent pacemaker implantation with Acurate (p < 0.05). In conclusion, new-generation TAVI devices have different profiles of early comparative safety and efficacy. These findings should be taken into account for individualized decision making and patient management.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Safety and effectiveness of a selective strategy for coronary artery revascularization before transcatheter aortic valve implantation
    Gasparetto, Valeria
    Fraccaro, Chiara
    Tarantini, Giuseppe
    Buja, Paolo
    D'Onofrio, Augusto
    Yzeiraj, Ermela
    Pittarello, Demetrio
    Isabella, Giambattista
    Gerosa, Gino
    Iliceto, Sabino
    Napodano, Massimo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (02) : 376 - 383
  • [42] Meta-Analysis of the Effectiveness and Safety of Transcatheter Aortic Valve Implantation Without Balloon Predilation
    Liao, Yan-biao
    Meng, Yang
    Zhao, Zhen-gang
    Zuo, Zhi-liang
    Li, Yi-jian
    Xiong, Tian-yuan
    Cao, Jia-yu
    Xu, Yuan-ning
    Feng, Yuan
    Chen, Mao
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (10): : 1629 - 1635
  • [43] Transfemoral aortic valve implantation with new-generation devices: the repositionable Lotus vs. the balloon-expandable Edwards Sapien 3 valve
    Fovino, Luca Nai
    Badawy, Mostafa R. A.
    Fraccaro, Chiara
    D'Onofrio, Augusto
    Purita, Paola A. M.
    Frigo, Anna C.
    Tellaroli, Paola
    Mauro, Agnifili
    Tusa, Maurizio
    Napodano, Massimo
    Gerosa, Gino
    Iliceto, Sabino
    Bedogni, Francesco
    AbdelRheim, Alaa E. R.
    Tarantini, Giuseppe
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2018, 19 (11) : 655 - 663
  • [44] First-in-man use of the new-generation TriGUARD 3 cerebral embolic protection device during transcatheter aortic valve implantation
    Paradis, Jean-Michel
    Nazif, Tamim M.
    Rodes-Cabau, Josep
    EUROINTERVENTION, 2018, 14 (11) : E1178 - E1179
  • [45] One-year safety and efficacy profile of transcatheter aortic valve-in-valve implantation with the portico system
    Casenghi, Matteo
    Gorla, Riccardo
    Popolo Rubbio, Antonio
    De Marco, Federico
    Brambilla, Nedy
    Agnifili, Mauro
    Testa, Luca
    Bedogni, Francesco
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2021, 98 (01) : E145 - E152
  • [46] Impact of prior hospitalization for heart failure on clinical outcomes of patients after transcatheter aortic valve implantation with new-generation devices: Insights from the LAPLACE-TAVI registry
    Fukutomi, Motoki
    Onishi, Takayuki
    Ando, Tomo
    Higuchi, Ryosuke
    Hagiya, Kenichi
    Saji, Mike
    Takamisawa, Itaru
    Iguchi, Nobuo
    Takayama, Morimasa
    Shimizu, Atsushi
    Shimizu, Jun
    Doi, Shinichiro
    Okazaki, Shinya
    Sato, Kei
    Tamura, Harutoshi
    Yokoyama, Hiroaki
    Takanashi, Shuichiro
    Tobaru, Tetsuya
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024,
  • [47] Safety and efficacy of cerebral embolic protection devices in transcatheter aortic valve implantation: a meta-analysis
    Tan, N.
    Gao, F.
    Mohammed, R. A.
    Lim, S. T.
    Aziz, Z. Abdul
    Govindasamy, S.
    Chao, V. T. T.
    Ewe, S. H.
    Ho, K. W.
    Yap, J.
    EUROPEAN HEART JOURNAL, 2023, 44 : 120 - 120
  • [48] Short- and mid-term safety and effectiveness of transcatheter aortic valve implantation in a failing surgical aortic bioprosthesis
    Ong, Sea Hing
    Bauernschmitt, Robert
    Schuler, Gerhard
    Mueller, Ralf
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (02) : 268 - 276
  • [49] Short- and Long-Term Safety and Effectiveness of Transcatheter Aortic Valve Implantation in a Failing Surgical Aortic Bioprosthesis
    Mueller, Ralf
    Bauernschmitt, Robert
    Schuler, Gerhard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B35 - B35
  • [50] Effectiveness and Safety of Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis (&lt;40%, 40%-49%, and &gt;50%)
    Merdler, Ilan
    Loewenstein, Itamar
    Hochstadt, Aviram
    Morgan, Samuel
    Schwarzbard, Sivan
    Sadeh, Ben
    Peri, Yogev
    Shacham, Yacov
    Finkelstein, Ariel
    Steinvil, Arie
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (04): : 583 - 588