Comparative one-month safety and effectiveness of five leading new-generation devices for transcatheter aortic valve implantation

被引:28
|
作者
Giordano, Arturo [1 ]
Corcione, Nicola [1 ]
Ferraro, Paolo [2 ]
Morello, Alberto [1 ]
Conte, Sirio [2 ]
Testa, Luca [3 ]
Bedogni, Francesco [3 ]
Iadanza, Alessandro [4 ]
Berti, Sergio [5 ]
Regazzoli, Damiano [6 ]
Romagnoli, Enrico [7 ]
Trani, Carlo [7 ]
Burzotta, Francesco [7 ]
Pepe, Martino [8 ]
Frati, Giacomo [9 ,10 ]
Biondi-Zoccai, Giuseppe [9 ,11 ]
Tamburino, Corrado [12 ]
Ettori, Federica [13 ]
Petronio, Anna Sonia [14 ]
Rinaldi, Mauro [15 ]
Klugmann, Silvio [16 ]
Rubino, Paolo [17 ]
Tremoli, Elena [18 ]
Marchese, Alfredo [19 ]
Sardella, Gennaro [20 ]
Pistis, Gianfranco [21 ]
Brscic, Elvis [22 ]
Giudice, Pietro [23 ]
Piatti, Luigi [24 ]
Ardissino, Diego [25 ]
Indolfi, Ciro [26 ]
Chiarella, Francesco [27 ]
Tespili, Maurizio [28 ]
De Servi, Stefano [29 ]
Bonmassari, Roberto [30 ]
Fappani, Antonio [31 ]
Cuccia, Claudio [32 ]
Cremonesi, Alberto [33 ]
Tomai, Fabrizio [34 ]
机构
[1] Pineta Grande Hosp, Unita Operat Interventist Cardiovasc, Castel Volturno, Italy
[2] Santa Lucia Hosp, Unita Operat Emodinam, San Giuseppe Vesuviano, Italy
[3] IRCCS Policlin San Donato, Dept Cardiol, Milan, Italy
[4] Policlin Santa Maria Scotte, Dipartimento Sci Cardiache Torac & Vasc, Div Emodinam, Siena, Italy
[5] Fdn CNR G Monasterio Osped Cuore, Massa, Italy
[6] Humanitas Univ, Dept Biomed Sci, Rozzano, Italy
[7] Univ Cattolica Sacro Cuore, Inst Cardiol, Fdn Policlin Univ A Gemelli IRCCS, Rome, Italy
[8] Univ Bari, Div Cardiol, Dept Emergency & Organ Transplantat, Bari, Italy
[9] Sapienza Univ Rome, Dept Medicosurg Sci & Biotechnol, Latina, Italy
[10] IRCCS NEUROMED, Pozzilli, Italy
[11] Mediterranea Cardioctr, Naples, Italy
[12] Univ Catania, Catania, Italy
[13] Spedali Civili Brescia, Brescia, Italy
[14] Univ Pisa, Pisa, Italy
[15] Univ Turin, Turin, Italy
[16] Osped Niguarda Ca Granda, Milan, Italy
[17] Clin Montevergine, Avellino, Italy
[18] Ctr Cardiol Monzino, Milan, Italy
[19] Anthea Hosp GVM Care & Res, Bari, Italy
[20] Sapienza Univ Rome, Policlin Umberto 1, Rome, Italy
[21] SS Antonio & Biagio & Cesare Arrigo Hosp, Alessandria, Italy
[22] Maria Pia Hosp, Turin, Italy
[23] San Giovanni di Dio & Ruggi Aragona, Salerno, Italy
[24] Osped Lecco, Lecce, Italy
[25] Azienda Osped Univ Parma, Parma, Italy
[26] Policlin Univ Mater Domini, Catanzaro, Italy
[27] IRCCS San Martino, Genoa, Italy
[28] Osped Bolognini, Seriate, Italy
[29] Osped Civile Legnano, Legnano, Italy
[30] Osped S Chiara, Trento, Italy
[31] Ist Clin San Rocco, Ome, Italy
[32] Fdn Poliambulanza, Brescia, Italy
[33] Maria Cecilia Hosp, Cotignola, Italy
[34] European Hosp, Rome, Italy
关键词
REPLACEMENT; MULTICENTER; COREVALVE; SAPIEN;
D O I
10.1038/s41598-019-53081-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transcatheter aortic valve implantation (TAVI) for aortic stenosis is becoming an appealing alternative to surgical aortic valve replacement in high-risk patients and to medical therapy for inoperable ones. Several new-generation TAVI devices have been recently introduced, but comparative analyses are lacking. We aimed to compare 1-month outcomes associated with such five leading new-generation TAVI devices exploiting data collected in the prospective observational RISPEVA (Registro Italiano GISE sull'impianto di Valvola Aortica Percutanea) Study. We queried the dataset of the ongoing RISPEVA study to retrieve baseline, procedural and 1-month outcome details of patients undergoing TAVI with Acurate, Evolut, Portico, Lotus, and Sapien3. Analysis was based on unadjusted and propensity score-adjusted methods. We included 1976 patients, 234 (11.8%) treated with Acurate, 703 (35.6%) with Evolut, 151 (7.6%) with Lotus, 347 (17.6%) with Portico, and 541 (27.4%) with Sapien3. Unadjusted analysis for baseline features highlighted several significant differences, and other discrepancies were found for procedural features. Despite these differences, device and procedural success were similarly high (ranging from 98.0% to 99.4%, p > 0.05). However, procedural valve migration appeared more common with Acurate (p = 0.007), and major bleeding with Sapien3 (p = 0.002). Unadjusted analysis for 1-month outcomes also highlighted significant differences in the composite of death, stroke, myocardial infarction, major vascular complication, major bleeding, or renal failure (favoring Portico, p < 0.001), major vascular complications (favoring Lotus, p < 0.001), renal failure (favoring Portico, p = 0.035), and permanent pacemaker implantation (favoring Acurate, p < 0.001). Propensity score-adjusted analyses showed lower rates of major adverse events with Evolut and Portico (p < 0.05), major vascular complications with Lotus and Portico (p < 0.05), renal failure with Sapien3 (p < 0.05) and permanent pacemaker implantation with Acurate (p < 0.05). In conclusion, new-generation TAVI devices have different profiles of early comparative safety and efficacy. These findings should be taken into account for individualized decision making and patient management.
引用
收藏
页数:12
相关论文
共 50 条
  • [11] Pacemaker implantation rate after transcatheter aortic valve implantation with early and new-generation devices: a systematic review
    van Rosendael, Philippe J.
    Delgado, Victoria
    Bax, Jeroen J.
    EUROPEAN HEART JOURNAL, 2018, 39 (21) : 2003 - +
  • [12] Outcome of transcatheter aortic valve replacement in bicuspid aortic valve stenosis with new-generation devices
    Gorla, Riccardo
    Casenghi, Matteo
    Finotello, Alice
    De Marco, Federico
    Morganti, Simone
    Regazzoli, Damiano
    Bianchi, Giovanni
    Acerbi, Elena
    Rubbio, Antonio Popolo
    Brambilla, Nedy
    Testa, Luca
    Castriota, Fausto
    Auricchio, Ferdinando
    Reimers, Bernhard
    Bedogni, Francesco
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2021, 32 (01) : 20 - 28
  • [13] Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis
    Yoon, Sung-Han
    Lefevre, Thierry
    Ahn, Jung-Ming
    Perlman, Gidon Y.
    Dvir, Danny
    Latib, Azeem
    Barbanti, Marco
    Deuschl, Florian
    De Backer, Ole
    Blanke, Philipp
    Modine, Thomas
    Pache, Gregor
    Neumann, Franz-Josef
    Ruile, Philipp
    Arai, Takahide
    Ohno, Yohei
    Kaneko, Hidehiro
    Tay, Edgar
    Schofer, Niklas
    Holy, Erik W.
    Luk, Ngai H. V.
    Yong, Gerald
    Lu, Qingsheng
    Kong, William K. F.
    Hon, Jimmy
    Kao, Hsien-Li
    Lee, Michael
    Yin, Wei-Hsian
    Park, Duk-Woo
    Kang, Soo-Jin
    Lee, Seung-Whan
    Kim, Young-Hak
    Lee, Cheol Whan
    Park, Seong-Wook
    Kim, Hyo-Soo
    Butter, Christian
    Khalique, Omar K.
    Schaefer, Ulrich
    Nietlispach, Fabian
    Kodali, Susheel K.
    Leon, Martin B.
    Ye, Jian
    Chevalier, Bernard
    Leipsic, Jonathon
    Delgado, Victoria
    Bax, Jeroen J.
    Tamburino, Corrado
    Colombo, Antonio
    Sondergaard, Lars
    Webb, John G.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (11) : 1195 - 1205
  • [14] Current and new-generation transcatheter aortic valve devices: an update on emerging technologies
    Ielasi, Alfonso
    Latib, Azeem
    Tespili, Maurizio
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2013, 11 (10) : 1393 - 1405
  • [15] Safety and efficacy of minimalist transcatheter aortic valve implantation using a new-generation balloon-expandable transcatheter heart valve in bicuspid and tricuspid aortic valves
    Michel, Jonathan M.
    Frangieh, Antonio H.
    Giacoppo, Daniele
    Alvarez-Covarrubias, Hector A.
    Pellegrini, Costanza
    Rheude, Tobias
    Deutsch, Oliver
    Mayr, N. Patrick
    Rumpf, P. Moritz
    Stahli, Barbara E.
    Kastrati, Adnan
    Schunkert, Heribert
    Xhepa, Erion
    Joner, Michael
    Kasel, A. Markus
    CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (12) : 1993 - 2006
  • [16] Safety and efficacy of minimalist transcatheter aortic valve implantation using a new-generation balloon-expandable transcatheter heart valve in bicuspid and tricuspid aortic valves
    Jonathan M. Michel
    Antonio H. Frangieh
    Daniele Giacoppo
    Hector A. Alvarez-Covarrubias
    Costanza Pellegrini
    Tobias Rheude
    Oliver Deutsch
    N. Patrick Mayr
    P. Moritz Rumpf
    Barbara E. Stähli
    Adnan Kastrati
    Heribert Schunkert
    Erion Xhepa
    Michael Joner
    A. Markus Kasel
    Clinical Research in Cardiology, 2021, 110 : 1993 - 2006
  • [17] Network meta-analysis of new-generation valves for transcatheter aortic valve implantation
    Takagi, Hisato
    Hari, Yosuke
    Nakashima, Kouki
    Kuno, Toshiki
    Ando, Tomo
    HEART AND VESSELS, 2019, 34 (12) : 1984 - 1992
  • [18] Network meta-analysis of new-generation valves for transcatheter aortic valve implantation
    Hisato Takagi
    Yosuke Hari
    Kouki Nakashima
    Toshiki Kuno
    Tomo Ando
    Heart and Vessels, 2019, 34 : 1984 - 1992
  • [19] Efficacy and safety of new-generation transcatheter aortic valves: insights from the Israeli transcatheter aortic valve replacement registry
    Finkelstein, Ariel
    Steinvil, Arie
    Rozenbaum, Zach
    Halkin, Amir
    Banai, Shmuel
    Barbash, Israel
    Guetta, Victor
    Segev, Amit
    Danenberg, Haim
    Orvin, Katia
    Assa, Hana Vaknin
    Assali, Abid
    Kornowski, Ran
    CLINICAL RESEARCH IN CARDIOLOGY, 2019, 108 (04) : 430 - 437
  • [20] Efficacy and safety of new-generation transcatheter aortic valves: insights from the Israeli transcatheter aortic valve replacement registry
    Ariel Finkelstein
    Arie Steinvil
    Zach Rozenbaum
    Amir Halkin
    Shmuel Banai
    Israel Barbash
    Victor Guetta
    Amit Segev
    Haim Danenberg
    Katia Orvin
    Hana Vaknin Assa
    Abid Assali
    Ran Kornowski
    Clinical Research in Cardiology, 2019, 108 : 430 - 437