Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches

被引:79
|
作者
Bashar, Syed Khairul [1 ]
Han, Dong [1 ]
Hajeb-Mohammadalipour, Shirin [1 ]
Ding, Eric [2 ]
Whitcomb, Cody [2 ]
McManus, David D. [2 ]
Chon, Ki H. [1 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Massachusetts, Sch Med, Div Cardiol, Worcester, MA USA
基金
美国国家科学基金会;
关键词
MOTION ARTIFACT; ALGORITHM; BURDEN; STROKE;
D O I
10.1038/s41598-019-49092-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Detection of atrial fibrillation (AF) from a wrist watch photoplethysmogram (PPG) signal is important because the wrist watch form factor enables long term continuous monitoring of arrhythmia in an easy and non-invasive manner. We have developed a novel method not only to detect AF from a smart wrist watch PPG signal, but also to determine whether the recorded PPG signal is corrupted by motion artifacts or not. We detect motion and noise artifacts based on the accelerometer signal and variable frequency complex demodulation based time-frequency analysis of the PPG signal. After that, we use the root mean square of successive differences and sample entropy, calculated from the beat-to-beat intervals of the PPG signal, to distinguish AF from normal rhythm. We then use a premature atrial contraction detection algorithm to have more accurate AF identification and to reduce false alarms. Two separate datasets have been used in this study to test the efficacy of the proposed method, which shows a combined sensitivity, specificity and accuracy of 98.18%, 97.43% and 97.54% across the datasets.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Detection of atrial fibrillation using a wrist-worn device
    Solosenko, Andrius
    Petrenas, Andrius
    Paliakaite, Birute
    Sornmo, Leif
    Marozas, Vaidotas
    PHYSIOLOGICAL MEASUREMENT, 2019, 40 (02)
  • [22] BayesBeat: Reliable Atrial Fibrillation Detection from Noisy Photoplethysmography Data
    Das, Sarkar Snigdha Sarathi
    Shanto, Subangkar Karmaker
    Rahman, Masum
    Islam, Md Saiful
    Rahman, Atif Hasan
    Masud, Mohammad M.
    Ali, Mohammed Eunus
    PROCEEDINGS OF THE ACM ON INTERACTIVE MOBILE WEARABLE AND UBIQUITOUS TECHNOLOGIES-IMWUT, 2022, 6 (01):
  • [23] Detection of Arrhythmias Using Heart Rate Signals from Smartwatches
    Baca, Herwin Alayn Huillcen
    Toia, Agueda Munoz Del Carpio
    Torres, Jose Alfredo Sulla
    Montesinos, Roderick Cusirramos
    Salas, Lucia Alejandra Contreras
    Herrera, Sandra Catalina Correa
    APPLIED SCIENCES-BASEL, 2024, 14 (16):
  • [24] A training pipeline of an arrhythmia classifier for atrial fibrillation detection using Photoplethysmography signal
    Kudo, Sota
    Chen, Zheng
    Zhou, Xue
    Izu, Leighton T.
    Chen-Izu, Ye
    Zhu, Xin
    Tamura, Toshiyo
    Kanaya, Shigehiko
    Huang, Ming
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [25] Atrial fibrillation detection from raw photoplethysmography waveforms: A deep learning application
    Aschbacher, Kirstin
    Yilmaz, Defne
    Kerem, Yaniv
    Crawford, Stuart
    Benaron, David
    Liu, Jiaqi
    Eaton, Meghan
    Tison, Geoffrey H.
    Olgin, Jeffrey E.
    Li, Yihan
    Marcus, Gregory M.
    HEART RHYTHM O2, 2020, 1 (01): : 3 - 9
  • [26] Computationally Efficient Algorithm for Photoplethysmography-Based Atrial Fibrillation Detection Using Smartphones
    Schaeck, Tim
    Harb, Yosef Safi
    Muma, Michael
    Zoubir, Abdelhak M.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 104 - 108
  • [27] Atrial fibrillation detection using ambulatory smartwatch photoplethysmography and validation with simultaneous holter recording
    Chang, Po-Cheng
    Wen, Ming-Shien
    Chou, Chung-Chuan
    Wang, Chun-Chieh
    Hung, Kuo-Chun
    AMERICAN HEART JOURNAL, 2022, 247 : 55 - 62
  • [28] Photoplethysmography-Based Smart Devices for Detection of Atrial Fibrillation
    Sijercic, Adna
    Tahirovic, Elnur
    TEXAS HEART INSTITUTE JOURNAL, 2022, 49 (05)
  • [29] Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis
    Gill, Simrat
    Bunting, Karina, V
    Sartini, Claudio
    Cardoso, Victor Roth
    Ghoreishi, Narges
    Uh, Hae-Won
    Williams, John A.
    Suzart-Woischnik, Kiliana
    Banerjee, Amitava
    Asselbergs, Folkert W.
    Eijkemans, Mjc
    Gkoutos, Georgios, V
    Kotecha, Dipak
    HEART, 2022, 108 (20) : 1600 - 1607
  • [30] Wrist band photoplethysmography pulse morphology-based autocorrelation analysis enables atrial fibrillation detection without the need of pulse detection
    Valiaho, E. -S.
    Kuoppa, P.
    Lipponen, J. A.
    Martikainen, T. J.
    Jantti, H.
    Rissanen, T. T.
    Kolk, I.
    Castren, M.
    Halonen, J.
    Tarvainen, M. P.
    Hartikainen, J. E. K.
    EUROPEAN HEART JOURNAL, 2019, 40 : 4137 - 4137