Smartphone detection of atrial fibrillation using photoplethysmography: a systematic review and meta-analysis

被引:19
|
作者
Gill, Simrat [1 ,2 ]
Bunting, Karina, V [1 ,2 ]
Sartini, Claudio [3 ]
Cardoso, Victor Roth [1 ,2 ,4 ]
Ghoreishi, Narges [3 ]
Uh, Hae-Won [5 ]
Williams, John A. [2 ,4 ]
Suzart-Woischnik, Kiliana [3 ]
Banerjee, Amitava [6 ]
Asselbergs, Folkert W. [7 ,8 ,9 ]
Eijkemans, Mjc [5 ]
Gkoutos, Georgios, V [2 ,4 ]
Kotecha, Dipak [1 ,2 ,7 ]
机构
[1] Univ Birmingham, Inst Cardiovasc Sci, Birmingham, W Midlands, England
[2] Univ Hosp Birmingham NHS Fdn Trust, Hlth Data Res UK Midlands Site, Birmingham, W Midlands, England
[3] Bayer AG, Med Affairs & Pharmacovigilance Pharmaceut Integr, Leverkusen, Nordrhein Westf, Germany
[4] Univ Birmingham, Inst Canc & Genom Sci, Birmingham, W Midlands, England
[5] Univ Med Ctr, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[6] UCL, Farr Inst Hlth Informat Res, London, England
[7] Univ Med Ctr Utrecht, Dept Cardiol, Utrecht, Netherlands
[8] UCL, Dept Cardiol, Fac Populat Hlth Sci, London, England
[9] UCL, Fac Populat Hlth Sci, Inst Cardiovasc Sci, London, England
关键词
atrial fibrillation; smartphone; photoplethysmography; DIAGNOSTIC-ACCURACY;
D O I
10.1136/heartjnl-2021-320417
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives Timely diagnosis of atrial fibrillation (AF) is essential to reduce complications from this increasingly common condition. We sought to assess the diagnostic accuracy of smartphone camera photoplethysmography (PPG) compared with conventional electrocardiogram (ECG) for AF detection. Methods This is a systematic review of MEDLINE, EMBASE and Cochrane (1980-December 2020), including any study or abstract, where smartphone PPG was compared with a reference ECG (1, 3 or 12-lead). Random effects meta-analysis was performed to pool sensitivity/specificity and identify publication bias, with study quality assessed using the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies-2) risk of bias tool. Results 28 studies were included (10 full-text publications and 18 abstracts), providing 31 comparisons of smartphone PPG versus ECG for AF detection. 11 404 participants were included (2950 in AF), with most studies being small and based in secondary care. Sensitivity and specificity for AF detection were high, ranging from 81% to 100%, and from 85% to 100%, respectively. 20 comparisons from 17 studies were meta-analysed, including 6891 participants (2299 with AF); the pooled sensitivity was 94% (95% CI 92% to 95%) and specificity 97% (96%-98%), with substantial heterogeneity (p<0.01). Studies were of poor quality overall and none met all the QUADAS-2 criteria, with particular issues regarding selection bias and the potential for publication bias. Conclusion PPG provides a non-invasive, patient-led screening tool for AF. However, current evidence is limited to small, biased, low-quality studies with unrealistically high sensitivity and specificity. Further studies are needed, preferably independent from manufacturers, in order to advise clinicians on the true value of PPG technology for AF detection.
引用
收藏
页码:1600 / 1607
页数:8
相关论文
共 50 条
  • [1] Accurate detection of atrial fibrillation using a smartphone remains uncertain: a systematic review and meta-analysis
    Gill, S.
    Sartini, C.
    Uh, H. W.
    Ghoreishi, N.
    Cardoso, V
    Bunting, K., V
    Gkoutos, G.
    Suzart-Woischnik, K.
    Asselbergs, F. W.
    Eijkemans, M. J. C.
    Kotecha, D.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 3505 - 3505
  • [2] Accuracy of Smartphone Camera Applications for Detecting Atrial Fibrillation A Systematic Review and Meta-analysis
    O'Sullivan, Jack W.
    Grigg, Sam
    Crawford, William
    Turakhia, Mintu P.
    Perez, Marco
    Ingelsson, Erik
    Wheeler, Matthew T.
    Ioannidis, John P. A.
    Ashley, Euan A.
    [J]. JAMA NETWORK OPEN, 2020, 3 (04) : E202064
  • [3] Bisphosphonates and Atrial Fibrillation Systematic Review and Meta-Analysis
    Loke, Yoon Kong
    Jeevanantham, Vinodh
    Singh, Sonal
    [J]. DRUG SAFETY, 2009, 32 (03) : 219 - 228
  • [4] Biomarkers for Atrial Fibrillation Detection After Stroke Systematic Review and Meta-analysis
    Cameron, Alan
    Cheng, Huen Ki
    Lee, Ren-Ping
    Doherty, Daniel
    Hall, Mark
    Khashayar, Pouria
    Lip, Gregory Y. H.
    Quinn, Terence
    Abdul-Rahim, Azmil
    Dawson, Jesse
    [J]. NEUROLOGY, 2021, 97 (18) : E1775 - E1789
  • [5] Accuracy of Apple Watch for Detection of Atrial Fibrillation: A Systematic Review and Meta-Analysis
    Yasmin, Farah
    Moeed, Abdul
    Adil, Mariam
    Rahman, Saad Ur
    Wilson, F. Perry
    [J]. CIRCULATION, 2023, 148
  • [6] Atrial fibrillation detection using single lead portable electrocardiographic monitoring: a systematic review and meta-analysis
    Ramkumar, Satish
    Nerlekar, Nitesh
    D'Souza, Daniel
    Pol, Derek J.
    Kalman, Jonathan M.
    Marwick, Thomas H.
    [J]. BMJ OPEN, 2018, 8 (09):
  • [7] Cardiac monitoring for detection of atrial fibrillation after TIA: A systematic review and meta-analysis
    Korompoki, Eleni
    Del Giudice, Angela
    Hillmann, Steffi
    Malzahn, Uwe
    Gladstone, David J.
    Heuschmann, Peter
    Veltkamp, Roland
    [J]. INTERNATIONAL JOURNAL OF STROKE, 2017, 12 (01) : 33 - 45
  • [8] SYSTEMATIC REVIEW AND META-ANALYSIS OF ACCURACY OF DIAGNOSTIC TESTS FOR SCREEN DETECTION OF ATRIAL FIBRILLATION
    Thom, H.
    McAleenan, A.
    Davies, P.
    Okoli, G. N.
    Higgins, J.
    Hollingworth, W.
    Sterne, J.
    Feder, G.
    Eaton, D.
    Hingorani, A.
    Fawsitt, C.
    Lobban, T.
    Bryden, P. A.
    Richards, A.
    Sofat, R.
    Welton, N. J.
    [J]. VALUE IN HEALTH, 2016, 19 (07) : A685 - A685
  • [9] The Effect of Colchicine on Atrial Fibrillation: A Systematic Review and Meta-Analysis
    Kommu, Sharath
    Arepally, Shalini
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (02)
  • [10] Atrial fibrillation in cancer survivors – a systematic review and meta-analysis
    Yueyang Bao
    John Lee
    Udit Thakur
    Satish Ramkumar
    Thomas H. Marwick
    [J]. Cardio-Oncology, 9