Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches

被引:70
|
作者
Bashar, Syed Khairul [1 ]
Han, Dong [1 ]
Hajeb-Mohammadalipour, Shirin [1 ]
Ding, Eric [2 ]
Whitcomb, Cody [2 ]
McManus, David D. [2 ]
Chon, Ki H. [1 ]
机构
[1] Univ Connecticut, Dept Biomed Engn, Storrs, CT 06269 USA
[2] Univ Massachusetts, Sch Med, Div Cardiol, Worcester, MA USA
基金
美国国家科学基金会;
关键词
MOTION ARTIFACT; ALGORITHM; BURDEN; STROKE;
D O I
10.1038/s41598-019-49092-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Detection of atrial fibrillation (AF) from a wrist watch photoplethysmogram (PPG) signal is important because the wrist watch form factor enables long term continuous monitoring of arrhythmia in an easy and non-invasive manner. We have developed a novel method not only to detect AF from a smart wrist watch PPG signal, but also to determine whether the recorded PPG signal is corrupted by motion artifacts or not. We detect motion and noise artifacts based on the accelerometer signal and variable frequency complex demodulation based time-frequency analysis of the PPG signal. After that, we use the root mean square of successive differences and sample entropy, calculated from the beat-to-beat intervals of the PPG signal, to distinguish AF from normal rhythm. We then use a premature atrial contraction detection algorithm to have more accurate AF identification and to reduce false alarms. Two separate datasets have been used in this study to test the efficacy of the proposed method, which shows a combined sensitivity, specificity and accuracy of 98.18%, 97.43% and 97.54% across the datasets.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches
    Syed Khairul Bashar
    Dong Han
    Shirin Hajeb-Mohammadalipour
    Eric Ding
    Cody Whitcomb
    David D. McManus
    Ki H. Chon
    [J]. Scientific Reports, 9
  • [2] Atrial Fibrillation Detection from Wrist Photoplethysmography Data Using Artificial Neural Networks
    Yousefi, Zeinab Rezaei
    Parak, Jakub
    Tarniceriu, Adrian
    Harju, Jarkko
    Yli-Hankala, Arvi
    Korhonen, Ilkka
    Vehkaoja, Antti
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 2, 2019, 68 (02): : 399 - 404
  • [3] Smartwatch Based Atrial Fibrillation Detection from Photoplethysmography Signals
    Bashar, Syed Khairul
    Han, Dong
    Ding, Eric
    Whitcomb, Cody
    McManus, David D.
    Chon, Ki H.
    [J]. 2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4306 - 4309
  • [4] Impact of recording length and other arrhythmias on atrial fibrillation detection from wrist photoplethysmogram using smartwatches
    Liao, Min-Tsun
    Yu, Chih-Chieh
    Lin, Lian-Yu
    Pan, Ke-Han
    Tsai, Tsung-Hsien
    Wu, Yu-Chun
    Liu, Yen-Bin
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [5] Impact of recording length and other arrhythmias on atrial fibrillation detection from wrist photoplethysmogram using smartwatches
    Min-Tsun Liao
    Chih-Chieh Yu
    Lian-Yu Lin
    Ke-Han Pan
    Tsung-Hsien Tsai
    Yu-Chun Wu
    Yen-Bin Liu
    [J]. Scientific Reports, 12
  • [6] Atrial fibrillation detection on reconstructed photoplethysmography signals collected from a smartwatch using a denoising autoencoder
    Mohagheghian, Fahimeh
    Han, Dong
    Ghetia, Om
    Chen, Darren
    Peitzsch, Andrew
    Nishita, Nishat
    Ding, Eric Y.
    Otabil, Edith Mensah
    Noorishirazi, Kamran
    Hamel, Alexander
    Dickson, Emily L.
    Dimezza, Danielle
    Tran, Khanh-Van
    Mcmanus, David D.
    Chon, Ki H.
    [J]. EXPERT SYSTEMS WITH APPLICATIONS, 2024, 237
  • [7] Wrist band photoplethysmography in detection of individual pulses in atrial fibrillation and algorithm-based detection of atrial fibrillation
    Valiaho, E-S
    Kuoppa, P.
    Lipponen, J. A.
    Martikainen, T. J.
    Jantti, H.
    Rissanen, T. T.
    Kolk, I
    Castren, M.
    Halonen, J.
    Tarvainen, M. P.
    Hartikainen, J. E. K.
    [J]. EUROPACE, 2019, 21 (07): : 1031 - 1038
  • [8] Wrist Band Photoplethysmography Autocorrelation Analysis Enables Detection of Atrial Fibrillation Without Pulse Detection
    Valiaho, Eemu-Samuli
    Kuoppa, Pekka
    Lipponen, Jukka A.
    Hartikainen, Juha E. K.
    Jantti, Helena
    Rissanen, Tuomas T.
    Kolk, Indrek
    Pohjantahti-Maaroos, Hanna
    Castren, Maaret
    Halonen, Jari
    Tarvainen, Mika P.
    Santala, Onni E.
    Martikainen, Tero J.
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [9] The Accuracy of Atrial Fibrillation Detection from Wrist Photoplethysmography. A Study on Post-Operative Patients
    Tarniceriu, Adrian
    Harju, Jarkko
    Yousefi, Zeinab Rezaei
    Vehkaoja, Antti
    Parak, Jakub
    Yli-Hankala, Arvi
    Korhonen, Ilkka
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4844 - 4847
  • [10] Arrhythmias Beyond Atrial Fibrillation Detection Using Smartwatches: A Systematic Review
    Pay, Levent
    Yumurtas, Ahmet Cagdas
    Satti, Danish Iltaf
    Hui, Jeremy Man Ho
    Chan, Jeffrey Shi Kai
    Mahalwar, Gauranga
    Lee, Yan Hiu Athena
    Tezen, Ozan
    Birdal, Oguzhan
    Inan, Duygu
    Ozkan, Eyup
    Tse, Gary
    Cinier, Goksel
    [J]. ANATOLIAN JOURNAL OF CARDIOLOGY, 2023, 27 (03): : 126 - 131