Atrial Fibrillation Detection from Wrist Photoplethysmography Data Using Artificial Neural Networks

被引:3
|
作者
Yousefi, Zeinab Rezaei [1 ,2 ]
Parak, Jakub [1 ,2 ]
Tarniceriu, Adrian [3 ]
Harju, Jarkko [4 ]
Yli-Hankala, Arvi [4 ]
Korhonen, Ilkka [1 ,2 ]
Vehkaoja, Antti [1 ,2 ]
机构
[1] Tampere Univ Technol, BioMediTech Inst, Fac Biomed Sci & Engn, Espoo, Finland
[2] PulseOn Ltd, Espoo, Finland
[3] PulseOn SA, Neuchatel, Switzerland
[4] Tampere Univ Hosp, Dept Anesthesia, Tampere, Finland
关键词
Atrial fibrillation; Aartificial neural network; Photoplethysmography; Inter-beat-interval features;
D O I
10.1007/978-981-10-9038-7_75
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Atrial fibrillation (AF) can be detected by analysis of the rhythm of heartbeats. The development of photoplethysmography (PPG) technology has enabled comfortable and unobtrusive physiological monitoring of heart rate with a wrist-worn device. Therefore, it is important to examine the possibility of using PPG signal to detect AF episodes in real-world situations. The aim of this paper is to evaluate an AF detection method based on artificial neural networks (ANN) from PPG-derived beat-to-beat interval data used for primary screening or monitoring purposes. The proposed classifier is able to distinguish between AF and sinus rhythms (SR). In total 30 patients (15 with AF, 15 with SR, mean age 71.5 years) with multiple comorbidities were monitored during routine postoperative treatment. The monitoring included standard ECG and a wrist-worn PPG monitor with green and infrared light sources. The input features of the ANN are based on the information obtained from inter-beat interval (IBI) sequences of 30 consecutive PPG pulses. One of the main concerns about the PPG signals is their susceptibility to be corrupted by noise and artifacts mostly caused by subject movement. Therefore, in the proposed method the IBI reliability is automatically evaluated beforehand. The amount of uncertainty due to unreliable beats was 15.42%. The achieved sensitivity and specificity of AF detection for 30 beats sequences were 99: 20 +/- 1: 3% and 99: 54 +/- 0: 64%, respectively. Based on these results, the ANN algorithm demonstrated excellent performance at recognizing AF from SR using wrist PPG data.
引用
收藏
页码:399 / 404
页数:6
相关论文
共 50 条
  • [1] Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches
    Syed Khairul Bashar
    Dong Han
    Shirin Hajeb-Mohammadalipour
    Eric Ding
    Cody Whitcomb
    David D. McManus
    Ki H. Chon
    [J]. Scientific Reports, 9
  • [2] Atrial Fibrillation Detection from Wrist Photoplethysmography Signals Using Smartwatches
    Bashar, Syed Khairul
    Han, Dong
    Hajeb-Mohammadalipour, Shirin
    Ding, Eric
    Whitcomb, Cody
    McManus, David D.
    Chon, Ki H.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] Wrist band photoplethysmography in detection of individual pulses in atrial fibrillation and algorithm-based detection of atrial fibrillation
    Valiaho, E-S
    Kuoppa, P.
    Lipponen, J. A.
    Martikainen, T. J.
    Jantti, H.
    Rissanen, T. T.
    Kolk, I
    Castren, M.
    Halonen, J.
    Tarvainen, M. P.
    Hartikainen, J. E. K.
    [J]. EUROPACE, 2019, 21 (07): : 1031 - 1038
  • [4] BayesBeat: Reliable Atrial Fibrillation Detection from Noisy Photoplethysmography Data
    Das, Sarkar Snigdha Sarathi
    Shanto, Subangkar Karmaker
    Rahman, Masum
    Islam, Md Saiful
    Rahman, Atif Hasan
    Masud, Mohammad M.
    Ali, Mohammed Eunus
    [J]. PROCEEDINGS OF THE ACM ON INTERACTIVE MOBILE WEARABLE AND UBIQUITOUS TECHNOLOGIES-IMWUT, 2022, 6 (01):
  • [5] Atrial Fibrillation Detection Using Convolutional Neural Networks
    Chandra, B. S.
    Sastry, C. S.
    Jana, S.
    Patidar, S.
    [J]. 2017 COMPUTING IN CARDIOLOGY (CINC), 2017, 44
  • [6] Atrial Fibrillation Detection Using Convolutional Neural Networks
    Zhou, Xue
    Zhu, Xin
    Nakamura, Keijiro
    Noro, Mahito
    [J]. 2018 9TH INTERNATIONAL CONFERENCE ON AWARENESS SCIENCE AND TECHNOLOGY (ICAST), 2018, : 84 - 89
  • [7] Wrist Band Photoplethysmography Autocorrelation Analysis Enables Detection of Atrial Fibrillation Without Pulse Detection
    Valiaho, Eemu-Samuli
    Kuoppa, Pekka
    Lipponen, Jukka A.
    Hartikainen, Juha E. K.
    Jantti, Helena
    Rissanen, Tuomas T.
    Kolk, Indrek
    Pohjantahti-Maaroos, Hanna
    Castren, Maaret
    Halonen, Jari
    Tarvainen, Mika P.
    Santala, Onni E.
    Martikainen, Tero J.
    [J]. FRONTIERS IN PHYSIOLOGY, 2021, 12
  • [8] The Accuracy of Atrial Fibrillation Detection from Wrist Photoplethysmography. A Study on Post-Operative Patients
    Tarniceriu, Adrian
    Harju, Jarkko
    Yousefi, Zeinab Rezaei
    Vehkaoja, Antti
    Parak, Jakub
    Yli-Hankala, Arvi
    Korhonen, Ilkka
    [J]. 2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4844 - 4847
  • [9] Atrial fibrillation classification with artificial neural networks
    Kara, Sadik
    Okandan, Mustafa
    [J]. PATTERN RECOGNITION, 2007, 40 (11) : 2967 - 2973
  • [10] Atrial Fibrillation Detection using Photo-plethysmography and Acceleration Data at the Wrist
    Bonomi, Alberto G.
    Schipper, Fons
    Eerikainen, Linda M.
    Margarito, Jenny
    Aarts, Ronald M.
    Babaeizadeh, Saeed
    de Morree, Helma M.
    Dekker, Lukas
    [J]. 2016 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 43, 2016, 43 : 277 - 280