High-performance liquid chromatographic assay of a new HIV-1 protease inhibitor, LB71350, in the plasma of dogs

被引:1
|
作者
Jeong, YN [1 ]
Seo, MK [1 ]
Choi, YJ [1 ]
Kim, IC [1 ]
Lee, YH [1 ]
机构
[1] LG Chem Biotech Res Inst, Taejon 305380, South Korea
来源
JOURNAL OF CHROMATOGRAPHY B | 1997年 / 703卷 / 1-2期
关键词
HIV-1 protease inhibitor; LB71350;
D O I
10.1016/S0378-4347(97)00395-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of LB71350 in the plasma of dogs. The analyte was deproteinized with 1.5 volumes of methanol and 0.5 volumes of 10% zinc sulfate, and the supernatant was injected into a 5-mu m Capcell Pak C-18 column (150x4.6 mm I.D.). The mobile phase was a stepwise gradient mixture of acetonitrile and 0.2% triethylamine-HCl with a flow-rate of 1 ml/min and detection at UV 245 nm. The proportion of acetonitrile was kept at 52% for the first 6 min, increased to 100% for the next 0.5 min, kept at 100% for the next 2 min, decreased to 52% for the next 0.5 min, and finally kept at 52% for the next 7 min. The retention time of LB71350 was 6.9 min. The calibration was linear over the concentration range of 0.1-100 mg/l for dog plasma (r>0.997) and the limit of quantitation was 0.1 mg/l using 0.1 ml plasma. The quality control samples were reproducible with acceptable accuracy and precision at 0.1, 1, 10 and 100 mg/l concentrations. The within-day recover); (n=5) was 90.2-93.9%, the between-day recovery (n=5) was 89.5-93.5%, and the absolute between-day recovery (n=5) was 77-81%. The within-day precision (n=5) and between-day precision (n=5) were 2.59-5.82% and 3.17-4.55%, respectively. No interferences from endogenous substances were observed. Taken together, the above HPLC assay method by deproteinization and UV detection was suitable for the determination of LB71350 in the preclinical pharmacokinetics. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:284 / 288
页数:5
相关论文
共 50 条
  • [21] High-Performance Liquid Chromatographic Assay for the Determination of Nilotinib in Human Plasma
    Yuki, Misato
    Yamakawa, Yuji
    Uchida, Takashi
    Nambu, Takeru
    Kawaguchi, Tatsuya
    Hamada, Akinobu
    Saito, Hideyuki
    BIOLOGICAL & PHARMACEUTICAL BULLETIN, 2011, 34 (07) : 1126 - 1128
  • [22] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR NITROFURANTOIN IN PLASMA AND URINE
    AUFRERE, MB
    HOENER, BA
    VORE, ME
    CLINICAL CHEMISTRY, 1977, 23 (12) : 2207 - 2212
  • [23] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR PLASMA DIPYRIDAMOLE MONITORING
    WILLIAMS, C
    HUANG, CS
    ERB, R
    GONZALEZ, MA
    JOURNAL OF CHROMATOGRAPHY, 1981, 225 (01): : 225 - 230
  • [24] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR TRIMETREXATE IN HUMAN PLASMA
    BULLEN, WW
    CHANG, T
    WHITFIELD, LR
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 526 (01): : 266 - 272
  • [25] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF AMIODARONE AND DESETHYLAMIODARONE IN PLASMA
    HUTCHINGS, A
    SPRAGG, BP
    ROUTLEDGE, PA
    JOURNAL OF CHROMATOGRAPHY, 1986, 382 : 389 - 393
  • [26] A HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF AMIODARONE AND DESETHYLAMIODARONE IN PLASMA
    HUTCHINGS, A
    WATT, AH
    SPRAGG, BP
    STEPHENS, MR
    ROUTLEDGE, PA
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1985, 20 (03) : P299 - P299
  • [27] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC RADIOENZYMATIC ASSAY FOR PLASMA CATECHOLAMINES
    KLANIECKI, TS
    CORDER, CN
    MCDONALD, RH
    FELDMAN, JA
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1977, 90 (04): : 604 - 612
  • [28] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY FOR THE MEASUREMENT OF ATOVAQUONE IN PLASMA
    DEANGELIS, DV
    LONG, JD
    KANICS, LL
    WOOLLEY, JL
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 652 (02): : 211 - 219
  • [29] Review of HIV-1 protease inhibitor assay methods
    Hur, Duik
    DiFrancesco, Robin
    Hochreiter, Jill
    Ma, Qing
    Slish, Judianne
    Maponga, Chiedza C.
    Morse, Gene D.
    CURRENT PHARMACEUTICAL ANALYSIS, 2007, 3 (03) : 180 - 185
  • [30] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC ASSAY OF DEXAMETHASONE IN PLASMA AND TISSUE
    CHAM, BE
    SADOWSKI, B
    OHAGAN, JM
    DEWYTT, CN
    BOCHNER, F
    EADIE, MJ
    THERAPEUTIC DRUG MONITORING, 1980, 2 (04) : 373 - 377