Characterization of forces applied by endoscopists during colonoscopy by using a wireless colonoscopy force monitor

被引:22
|
作者
Korman, Louis Y. [1 ]
Egorov, Vladimir [2 ]
Tsuryupa, Sergey [2 ]
Corbin, Brendan [2 ]
Anderson, Mary [1 ]
Sarvazyan, Noune [2 ]
Sarvazyan, Armen [2 ]
机构
[1] Chevy Chase Clin Res, Chevy Chase, MD 20815 USA
[2] Artann Labs, Trenton, NJ USA
关键词
COLORECTAL-CANCER; QUALITY INDICATORS; CECAL INTUBATION; UNITED-STATES; TASK-FORCE; POPULATION; SURVEILLANCE; PERFORMANCE; COMPETENCE; CAPACITY;
D O I
10.1016/j.gie.2009.08.029
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To perform a colonoscopy, the endoscopist maneuvers the colonoscope through a series of loops by applying force to the insertion tube. Colonoscopy insertion techniques ire operator dependent but have never been comprehensively quantified. Objective: To determine whether the Colonoscopy Force Monitor (CFM), a device that continually measures force applied to the insertion tube, can identify different force application patterns among experienced endoscopists. Design: Observational study of 6 experienced endoscopists performing routine diagnostic and therapeutic colonoscopy in 30 patients. Setting: Outpatient ambulatory endoscopy center. Patients: Adult male and female patients between 30 and 75 years of age undergoing routine colonoscopy. Interventions: CFM monitoring of force applied to the colonoscope insertion tube during colonoscopy. Main Outcome Measurements: Maximum and mean linear and torque force, time derivative of force, combined linear and torque vector force, and total manipulation time. Results: The CFM demonstrates differences among endoscopists for maximum and average push/pull and mean torque forces, time derivatives of force, combined push/torque force vector, and total manipulation time. Endoscopists could be grouped by force application patterns. Limitations: Only experienced endoscopists using conscious sedation in the patients were studied. Sample size was 30 patients. Conclusions: This study demonstrates that CFM allows continuous force monitoring, characterization, and display of similarities and differences in endoscopic technique. CFM has the potential to facilitate training by enabling trainees to assess, compare, and quantify their techniques and progress. (Gastrointest Endosc 2010;71:327-34.)
引用
收藏
页码:327 / 334
页数:8
相关论文
共 50 条
  • [31] Colonoscopy Force Monitor (CFM)™: New Tool for Teaching, Performance Assessment and Quality Assurance
    Sarvazyan, Armen
    Korman, Louis Y.
    Tsuryupa, Sergey
    Corbin, Brendan
    Sarvazyan, Noune
    GASTROINTESTINAL ENDOSCOPY, 2009, 69 (05) : AB372 - AB373
  • [32] Recording forces exerted on the bowel wall during colonoscopy: in vitro evaluation
    Dogramadzi, S
    Virk, GS
    Bell, GD
    Rowland, RS
    Hancock, J
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2005, 1 (04): : 89 - 97
  • [33] Hemodynamics during colonoscopy using impedance cardiography
    Asfari, W
    Miller, A
    Ramdan, Z
    Miller, L
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (05) : AB121 - AB121
  • [34] Air insufflation versus water infusion during colonoscopy by endoscopists-in-training: A randomized controlled trial
    Nido, Maria Thea Mulingbayan
    Chan, Melchor Mesa
    Carpio, Ramon
    Dy, Frederick Tang
    Ruiz, Estrellita Judan
    Go, Johnny
    Dalupang, Carmelita Dado
    Ngo, Denis
    Wong, Stephen
    Ismael, Albert Estrada
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2012, 27 : 178 - 179
  • [35] DOES THE PERSONALITY TRAITS OF ENDOSCOPISTS AFFECT ADENOMA DETECTION RATE DURING COLONOSCOPY? A KASID MULTICENTER STUDY
    Jung, Yunho
    Cha, Jae Myung
    Joo, Young-Eun
    Lee, Yoo Jin
    Kim, Hyun Gun
    Jeon, Seong Ran
    Shin, Jeong Eun
    Yang, Hyo-Joon
    Lee, Jun
    Kim, Kyeong Ok
    Kim, Jong Wook
    Na, Soo-Young
    Boo, Sun-Jin
    Koo, Hoon Sup
    Kim, Jae Hyun
    Han, Su Jung
    Yang, Jae Kook
    Han, Mee Jung
    Young, Hwangbo
    Huh, Kyu Chan
    GASTROINTESTINAL ENDOSCOPY, 2019, 89 (06) : AB409 - AB409
  • [36] EYE MOVEMENTS AND TASK LOAD OF ENDOSCOPISTS WHILE USING COMPUTER-AIDED DETECTION SYSTEM FOR COLONOSCOPY
    Kamba, Shunsuke
    Fukuda, Akihiro
    Sumiyama, Kazuki
    GASTROINTESTINAL ENDOSCOPY, 2022, 95 (06) : AB222 - AB222
  • [37] Detection of Looping During Colonoscopy Using Embedded Sensors
    Bruce, Mike
    Drozek, David
    Choi, JungHun
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2014, 8 (03):
  • [38] SATISFACTION AND EFFICACY USING PROPOFOL OR PETIDIN DURING COLONOSCOPY
    Caldarella, M. P.
    Pagliaricci, L.
    Petrocco, M.
    Marino, M.
    Tartaglia, M. T.
    DIGESTIVE AND LIVER DISEASE, 2017, 49 : E79 - E79
  • [39] Randomized trial of a video headset vs. a conventional video monitor during colonoscopy
    Lee, LS
    Carr-Locke, DL
    Ookubo, R
    Saltzman, JR
    GASTROINTESTINAL ENDOSCOPY, 2005, 61 (02) : 301 - 306
  • [40] Abdominal Wall Hematoma Resulting From Abdominal Pressure Applied During Colonoscopy
    Dixon, Robert E.
    McDonough, Stephanie
    Fang, John C.
    ACG CASE REPORTS JOURNAL, 2021, 8 (07)