Evaluation of a new thermometer for rapid axillary temperature measurement in preterm infants

被引:0
|
作者
Dollberg, S [1 ]
Mincis, L [1 ]
Mimouni, FB [1 ]
Ashbel, G [1 ]
Barak, M [1 ]
机构
[1] Tel Aviv Med Ctr & Sch Med, Lis Matern Hosp, Dept Neonatol, IL-64239 Tel Aviv, Israel
关键词
thermometry; preterm infants; accurate; reproducible;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Mercury-in-glass thermometers are considered the "gold-standard" for temperature measurements, but require at least 4 minutes for accuracy. Electronic thermometers sample temperature measurements over a shorter period. The objective of this study was to evaluate the accuracy and reproducibility of the Penguin (Medisim, Jerusalem, Israel) and the IVAC (San Diego, CA) Temp plus 11 thermometers in preterm infants. Axillary temperature was obtained in 50 thermally stable preterm. infants each time with the mercury-in-glass, the IVAC, and the Penguin thermometers. Analysis of variance F-test, and linear regression analyses were used to test correlation of each electronic thermometer with the mercury-in-glass one, and the effect of body weight. Temperature measurement taken with the Penguin thermometer was significantly higher than that measured with the two other ones, p < 0.001. The differences in means and in variances were not significantly different between IVAC and mercury-in-glass, while the variance of the Penguin measurement was higher than that of the two other instruments (P < 0.001). The IVAC instrument correlated more tightly with the mercury-in-glass (r = 0.89,p < 0.001) than did the Penguin (r = 0.54, P < 0.001). There was an inverse correlation between the deviation of the Penguin measurement from the mercury-in-glass and the weight of the patient (P < 0.08), while no significant correlation was found between the deviation of the IVAC measurement from the mercury in glass and the patient's weight (p = 0.56). Measurements of axillary temperature using the Penguin thermometer in incubated preterm infants are less accurate and less reproducible than those obtained using the IVAC or the glass thermometers.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [41] Measurement of cerebral oxygenation in preterm infants: is it useful?
    Austin, Topun
    DEVELOPMENTAL MEDICINE AND CHILD NEUROLOGY, 2015, 57 (05): : 404 - 405
  • [42] ACOUSTICAL THERMOMETER ADVANCES LOW-TEMPERATURE MEASUREMENT
    不详
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (12): : 2420 - &
  • [43] Reliability of an infrared auditory thermometer in the measurement of oral temperature
    Moya Villaescusa, M. Jose
    Perez, A. Sanchez
    Bermejo Fenoll, Ambrosio
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2008, 13 (06): : E385 - E389
  • [44] Evaluation of neutropenia and neutrophilia in preterm infants
    Nittala, Solomon
    Subbarao, Girish C.
    Maheshwari, Akhil
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 : 100 - 103
  • [45] Evaluation of eosinophilia in hospitalized preterm infants
    Juul S.E.
    Haynes J.W.
    McPherson R.J.
    Journal of Perinatology, 2005, 25 (3) : 182 - 188
  • [46] THE USE OF AN ELECTRONIC THERMOMETER IN INTRAORAL TEMPERATURE-MEASUREMENT
    HARUN, Z
    STAFFORD, GD
    HUGGETT, R
    JOURNAL OF ORAL REHABILITATION, 1988, 15 (03) : 285 - 293
  • [47] Intravesical thermometer: an unusual complication of vaginal temperature measurement
    Riou, PJ
    Harris, A
    JOURNAL OF ACCIDENT & EMERGENCY MEDICINE, 1998, 15 (06): : 432 - 432
  • [48] MEASUREMENT OF AVERAGE FACE TEMPERATURE USING INFRARED THERMOMETER
    NISHI, Y
    SUZUKI, K
    OOHORI, T
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1987, 31 (04) : 354 - 355
  • [49] ACCURACY OF TEMPERATURE MEASUREMENT BY A STANDARD PLATINUM RESISTANCE THERMOMETER
    SYCHEV, VV
    GORBUNOV.NI
    HIGH TEMPERATURE, 1965, 3 (04) : 579 - &
  • [50] MEASUREMENT OF COMMUTATOR TEMPERATURE BY A SLIDING-CONTACT THERMOMETER
    BATES, JJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1965, 112 (04): : 835 - &