Evaluation of a new thermometer for rapid axillary temperature measurement in preterm infants

被引:0
|
作者
Dollberg, S [1 ]
Mincis, L [1 ]
Mimouni, FB [1 ]
Ashbel, G [1 ]
Barak, M [1 ]
机构
[1] Tel Aviv Med Ctr & Sch Med, Lis Matern Hosp, Dept Neonatol, IL-64239 Tel Aviv, Israel
关键词
thermometry; preterm infants; accurate; reproducible;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Mercury-in-glass thermometers are considered the "gold-standard" for temperature measurements, but require at least 4 minutes for accuracy. Electronic thermometers sample temperature measurements over a shorter period. The objective of this study was to evaluate the accuracy and reproducibility of the Penguin (Medisim, Jerusalem, Israel) and the IVAC (San Diego, CA) Temp plus 11 thermometers in preterm infants. Axillary temperature was obtained in 50 thermally stable preterm. infants each time with the mercury-in-glass, the IVAC, and the Penguin thermometers. Analysis of variance F-test, and linear regression analyses were used to test correlation of each electronic thermometer with the mercury-in-glass one, and the effect of body weight. Temperature measurement taken with the Penguin thermometer was significantly higher than that measured with the two other ones, p < 0.001. The differences in means and in variances were not significantly different between IVAC and mercury-in-glass, while the variance of the Penguin measurement was higher than that of the two other instruments (P < 0.001). The IVAC instrument correlated more tightly with the mercury-in-glass (r = 0.89,p < 0.001) than did the Penguin (r = 0.54, P < 0.001). There was an inverse correlation between the deviation of the Penguin measurement from the mercury-in-glass and the weight of the patient (P < 0.08), while no significant correlation was found between the deviation of the IVAC measurement from the mercury in glass and the patient's weight (p = 0.56). Measurements of axillary temperature using the Penguin thermometer in incubated preterm infants are less accurate and less reproducible than those obtained using the IVAC or the glass thermometers.
引用
收藏
页码:201 / 204
页数:4
相关论文
共 50 条
  • [31] Comparison of rectal and axillary temperature measurements in preterm newborns
    McCarthy, Lisa K.
    O'Donnell, Colm Patrick Finbarr
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2021, 106 (05): : F509 - F513
  • [32] Detection of hypoxaemia in preterm infants: Evaluation of a new technology pulse oximeter
    Peter C.
    Bohnhorst B.
    Poets C.F.
    Pediatric Research, 1998, 44 (3) : 443 - 443
  • [33] How reliable is axillary temperature measurement?
    Falzon, A
    Grech, V
    Caruana, B
    Magro, A
    Attard-Montalto, S
    ACTA PAEDIATRICA, 2003, 92 (03) : 309 - 313
  • [34] TEMPERATURE MEASUREMENT IN INFANTS
    EOFF, MJF
    MEIER, RS
    MILLER, C
    NURSING RESEARCH, 1974, 23 (06) : 457 - 460
  • [35] Evaluation of Retinopathy of Prematurity in Preterm Infants
    Rasoulinejad, Seyed Ahmad
    INTERNATIONAL JOURNAL OF AYURVEDIC MEDICINE, 2019, 10 (02) : 185 - 188
  • [36] Evaluation of postnatal growth of preterm infants
    Bertino, Enrico
    Di Nicola, Paola
    Giuliani, Francesca
    Coscia, Alessandra
    Varalda, Alessia
    Occhi, Luciana
    Rossi, Claudia
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2011, 24 : 10 - 12
  • [37] ARTERIAL-PRESSURE MEASUREMENT IN PRETERM INFANTS
    BRIASSOULIS, G
    CRITICAL CARE MEDICINE, 1986, 14 (08) : 735 - 738
  • [38] Fiber-optic thermometer for high temperature measurement
    Aizawa, Hiroaki
    Katsumata, Tooru
    Komuro, Shuji
    Morikawa, Takitaro
    2006 SICE-ICASE INTERNATIONAL JOINT CONFERENCE, VOLS 1-13, 2006, : 4811 - +
  • [39] The evaluation of psychomotor development in preterm infants
    Rimdeikiene, Inesa
    Krisciunas, Aleksandras
    Markuniene, Egle
    MEDICINA-LITHUANIA, 2008, 44 (05): : 378 - 385
  • [40] Postnatal urinary conductance measurement in preterm infants
    Rangaraj, S
    Penney, MD
    Ferguson, SD
    ACTA PAEDIATRICA, 2002, 91 (05) : 561 - 565