Skull Modeling Effects in Conductivity Estimates Using Parametric Electrical Impedance Tomography

被引:37
|
作者
Fernandez-Corazza, Mariano [1 ,2 ]
Turovets, Sergei [2 ,3 ]
Phan Luu [2 ,3 ,4 ]
Price, Nick [5 ]
Muravchik, Carlos Horacio [1 ,6 ]
Tucker, Don [2 ,3 ,4 ]
机构
[1] Univ Nacl La Plata, CONICET, LEICI Inst Invest Elect Control & Procesamiento S, RA-1900 La Plata, Buenos Aires, Argentina
[2] Univ Oregon, Neuroinformat Ctr, Eugene, OR 97403 USA
[3] Philips EGI, Eugene, OR 97403 USA
[4] Univ Oregon, Dept Psychol, Eugene, OR 97403 USA
[5] Oregon Dept Human Serv, Eugene, OR USA
[6] Comis Invest Cient, La Plata, Buenos Aires, Argentina
关键词
Electrical impedance tomography; skull electrical conductivity; bioimpedance; biomedical signal processing; electroencephalography; DIRECT-CURRENT STIMULATION; HUMAN HEAD; IN-VIVO; VOLUME CONDUCTOR; DIELECTRIC-PROPERTIES; SOURCE LOCALIZATION; FIELD DISTRIBUTION; BRAIN; EEG; EIT;
D O I
10.1109/TBME.2017.2777143
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: To estimate scalp, skull, compact bone, and marrow bone electrical conductivity values based on electrical impedance tomography (EIT) measurements, and to determine the influence of skull modeling details on the estimates. Methods: We collected EIT data with 62 current injection pairs and built five 6-8 million finite element (FE) head models with different grades of skull simplifications for four subjects, including three whose head models serve as Atlases in the scientific literature and in commercial equipment (Colin27 and EGI's Geosource atlases). We estimated electrical conductivity of the scalp, skull, marrow bone, and compact bone tissues for each current injection pair, each model, and each subject. Results: Closure of skull holes in FE models, use of simplified four-layer boundary element method-like models, and neglecting the CSF layer produce an overestimation of the skull conductivity of 10%, 10%-20%, and 20%-30%, respectively (accumulated overestimation of 50%-70%). The average extracted conductivities are 288 +/- 53 (the scalp), 4.3 +/- 0.08 (the compact bone), and 5.5 + 1.25 (the whole skull) mS/m. The marrow bone estimates showed large dispersion. Conclusion: Present EIT estimates for the skull conductivity are lower than typical literature reference values, but previous in vivo EIT results are likely overestimated due to the use of simpler models. Significance: Typical literature values of 7-10 mS/m for skull conductivity should be replaced by the present estimated values when using detailed skull head models. We also provide subject specific conductivity estimates for widely used Atlas head models.
引用
收藏
页码:1785 / 1797
页数:13
相关论文
共 50 条
  • [31] Adaptive reconstruction for electrical impedance tomography with a piecewise constant conductivity
    Jin, Bangti
    Xu, Yifeng
    INVERSE PROBLEMS, 2020, 36 (01)
  • [32] Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
    Degirmenci, E.
    Eyuboglu, B. M.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 728 - 731
  • [33] Identifying conductivity in electrical impedance tomography with total variation regularization
    Michael Hinze
    Barbara Kaltenbacher
    Tran Nhan Tam Quyen
    Numerische Mathematik, 2018, 138 : 723 - 765
  • [34] ESTIMATION OF CONDUCTIVITY CHANGES IN A REGION OF INTEREST WITH ELECTRICAL IMPEDANCE TOMOGRAPHY
    Liu, Dong
    Kolehmainen, Ville
    Siltanen, Samuli
    Laukkanen, Anne-Maria
    Seppanen, Aku
    INVERSE PROBLEMS AND IMAGING, 2015, 9 (01) : 211 - 229
  • [35] Imaging of electrode movement and conductivity change in Electrical Impedance Tomography
    Gomez-Laberge, Camille
    Adler, Andy
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1029 - +
  • [36] AUTOMATIC SEGMENTATION OF CONDUCTIVITY CHANGES IN ELECTRICAL IMPEDANCE TOMOGRAPHY IMAGES
    Zifan, A.
    Liatsis, P.
    Kantartzis, P.
    Vargas-Canas, R.
    BIOSIGNALS 2011, 2011, : 215 - 220
  • [37] Electrical impedance tomography of complex conductivity distributions with noncircular boundary
    Jain, H
    Isaacson, D
    Edic, PM
    Newell, JC
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (11) : 1051 - 1060
  • [38] Resolution-Controlled Conductivity Discretization in Electrical Impedance Tomography
    Winkler, Robert
    Rieder, Andreas
    SIAM JOURNAL ON IMAGING SCIENCES, 2014, 7 (04): : 2048 - 2077
  • [39] High-Precision Electrical Impedance Tomography for Electrical Conductivity of Metallic Materials
    Zhao, Shuanfeng
    Miao, Yao
    Chai, Rongxia
    Zhao, Jiaojiao
    Bai, Yunrui
    Wei, Zheng
    Ren, Simin
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [40] High-Precision Electrical Impedance Tomography for Electrical Conductivity of Metallic Materials
    Zhao, Shuanfeng
    Miao, Yao
    Chai, Rongxia
    Zhao, Jiaojiao
    Bai, Yunrui
    Wei, Zheng
    Ren, Simin
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022