High-Precision Electrical Impedance Tomography for Electrical Conductivity of Metallic Materials

被引:0
|
作者
Zhao, Shuanfeng [1 ]
Miao, Yao [1 ]
Chai, Rongxia [1 ]
Zhao, Jiaojiao [1 ]
Bai, Yunrui [1 ]
Wei, Zheng [1 ]
Ren, Simin [1 ]
机构
[1] Xian Univ Sci & Technol, Sch Mech Engn, Xian 710054, Peoples R China
关键词
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Metal materials are subject to deformation, internal stress distribution, and cracking during processing, all of which affect the distribution of electrical conductivity of the metal. Suppose we can detect the conductivity distribution of metal materials in real time. In that case, we can complete the inverse imaging of metal material properties, structures, cracks, etc. and realize nondestructive flaw detection. However, metal materials' small resistance, high electrical conductivity, and susceptibility of voltage signals to noise signal interference make an accurate measurement of metal conductivity challenging. Therefore, this paper addresses the problem of detecting the conductivity distribution of metals by investigating a high-precision four-electrode AC measurement method. This technical approach combines laminar imaging techniques with high-precision weak signal extraction methods. On this basis, a method and equipment for high-precision electrical impedance tomography of metallic materials' electrical conductivity were established. The way specifies a new number of electrodes and adopts a model of spaced excitation reference measurements. Single-frequency sinusoidal AC signal is used for excitation, and Shannon wavelet analysis is used for signal extraction and noise reduction. Super-resolution reconstruction algorithms are used for resistivity distribution image reconstruction to improve image quality. Based on the results of various comparative experiments, it is clear that this new functional technique method has good imaging stability and operability and can perform tasks such as analyzing the internal conductivity distribution of metals. This research provides an effective way of new ideas for the safe detection of metal structures, the changes in crystal tissue structure, and the study of metal properties. In particular, it expands the scope of research in the development and application of resistance tomography, which has tremendous commercial potential research significance.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] High-Precision Electrical Impedance Tomography for Electrical Conductivity of Metallic Materials
    Zhao, Shuanfeng
    Miao, Yao
    Chai, Rongxia
    Zhao, Jiaojiao
    Bai, Yunrui
    Wei, Zheng
    Ren, Simin
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [2] High-Precision Electrical Impedance Tomography System Using Package Excitation
    Ouypornkochagorn, Taweechai
    Ngamdi, Napatsawan
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [3] High-Precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging
    Shi, Xuetao
    Li, Weichen
    You, Fusheng
    Huo, Xuyang
    Xu, Canhua
    Ji, Zhenyu
    Liu, Ruigang
    Liu, Benyuan
    Li, Yandong
    Fu, Feng
    Dong, Xiuzhen
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (14) : 5974 - 5984
  • [4] Design and Implementation of a High-precision Electrical Impedance Tomography Data Acquisition System for Brain Imaging
    Shi, Xuetao
    You, Fusheng
    Xu, Canhua
    Ji, Zhenyu
    Liu, Ruigang
    Dong, Xiuzhen
    Fu, Feng
    Huo, Xuyang
    [J]. PROCEEDINGS OF 2016 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS), 2016, : 9 - 13
  • [5] Fast High-Precision Electrical Impedance Tomography System for Real-Time Perfusion Imaging
    Li, Weichen
    Xia, Junying
    Zhang, Ge
    Ma, Hang
    Liu, Benyuan
    Yang, Lin
    Zhou, Yimin
    Dong, Xiuzhen
    Fu, Feng
    Shi, Xuetao
    [J]. IEEE ACCESS, 2019, 7 : 61570 - 61580
  • [6] High-Precision Electrical Resistance Tomography With External and Internal Electrode Arrays
    Ren, Shangjie
    Dong, Feng
    Tan, Chao
    [J]. 2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2011, : 1243 - 1248
  • [7] Imaging the complex conductivity in electrical impedance tomography
    Shallof, AM
    Barber, DC
    [J]. INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, PROCEEDINGS - VOL III, 1996, : 543 - 546
  • [8] Reconstructing the conductivity of nodes in electrical impedance tomography
    Li, XL
    He, XB
    Zhou, SC
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 1036 - 1037
  • [9] Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)
    Oh, SH
    Han, JY
    Lee, SY
    Cho, MH
    Lee, BI
    Woo, EJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (04) : 875 - 878
  • [10] A Rapid, Low-Cost, and High-Precision Multifrequency Electrical Impedance Tomography Data Acquisition System for Plant Phenotyping
    Basak, Rinku
    Wahid, Khan A.
    [J]. REMOTE SENSING, 2022, 14 (13)