Electrical conductivity imaging by magnetic resonance electrical impedance tomography (MREIT)

被引:19
|
作者
Oh, SH
Han, JY
Lee, SY
Cho, MH
Lee, BI
Woo, EJ
机构
[1] Kyung Hee Univ, Grad Sch East West Med Sci, Kyungki 449701, South Korea
[2] Kyung Hee Univ, Coll Elect & Informat, Kyungki, South Korea
关键词
electrical conductivity imaging; current density imaging; MRCDI; MREIT; J-substitution algorithm;
D O I
10.1002/mrm.10588
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance electrical impedance tomography (MREIT) is a recently developed imaging technique that combines MRI and electrical impedance tomography (EIT). In MREIT, cross-sectional electrical conductivity images are reconstructed from the internal magnetic field density data produced inside an electrically conducting subject when an electrical current is injected into the subject. In this work the results of an electrical conductivity imaging experiment are presented, along with some practical considerations regarding MREIT. The MREIT experiment was performed with a 0.3 Tesla MRI system on a phantom made of two compartments with different electrical conductivities. The current density inside the phantom was measured by the MR current density imaging (MRCDI) technique. The measured current density was then used for conductivity image reconstruction by the J-substitution algorithm. The conductivity phantom images obtained with an injection current of 28mA showed conductivity errors of about 25.5%. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:875 / 878
页数:4
相关论文
共 50 条
  • [1] Magnetic Resonance Electrical Impedance Tomography (MREIT): conductivity and current density imaging
    Seo, JK
    Kwon, O
    Woo, EJ
    [J]. SECOND INTERNATIONAL CONFERENCE ON INVERSE PROBLEMS: RECENT THEORETICAL DEVELOPMENTS AND NUMERICAL APPROACHES, 2004, 2005, 12 : 140 - 155
  • [2] Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging
    Woo, Eung Je
    Seo, Jin Keun
    [J]. PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) : R1 - R26
  • [3] Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Seo, Jin Keun
    Woo, Eung Je
    [J]. SIAM REVIEW, 2011, 53 (01) : 40 - 68
  • [4] Electrical conductivity imaging using gradient Bz decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
    Park, C
    Kwon, O
    Woo, EJ
    Seo, JK
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (03) : 388 - 394
  • [5] Fast conductivity imaging in magnetic resonance electrical impedance tomography (MREIT) for RF ablation monitoring
    Kwon, Oh In
    Chauhan, Munish
    Kim, Hyung Joong
    Jeong, Woo Chul
    Wi, Hun
    Oh, Tong In
    Woo, Eung Je
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2014, 30 (07) : 447 - 455
  • [6] A Novel Conductivity Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Wang, Yuyu
    Wang, Huixian
    Yang, Wenhui
    Hu, Xiaolin
    Song, Tao
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3976 - 3979
  • [7] Animal and Human Imaging Experiments in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Woo, Eung Je
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3165 - 3168
  • [8] Denoising of Bz data for conductivity reconstruction in magnetic resonance electrical impedance tomography (MREIT)
    Jeon, Kiwan
    Lee, Chang-Ock
    [J]. MATHEMATICAL AND STATISTICAL METHODS FOR IMAGING, 2011, 548 : 85 - 100
  • [9] Stability of the isotropic conductivity reconstruction using magnetic resonance electrical impedance tomography (MREIT)
    Wang, Haiyang
    Song, Yizhuang
    [J]. INVERSE PROBLEMS, 2024, 40 (07)
  • [10] Magnetic Resonance Electrical Impedance Tomography For Anisotropic Conductivity Imaging
    Degirmenci, E.
    Eyuboglu, B. M.
    [J]. 4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 728 - 731