Dosimetry for BNCT in theory and practice

被引:0
|
作者
Watkins, P [1 ]
Moss, RL [1 ]
Stecher-Rasmussen, F [1 ]
Voorbraak, W [1 ]
机构
[1] Commiss European Communities, Inst Adv Mat, Joint Res Ctr, NL-1755 ZG Petten, Netherlands
关键词
D O I
暂无
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
引用
收藏
页码:A141 / A146
页数:4
相关论文
共 50 条
  • [31] Combined TL and 10B-alanine ESR dosimetry for bnct
    Bartolotta, A
    D'Oca, MC
    Lo Giudice, B
    Brai, M
    Borio, R
    Forini, N
    Salvadori, P
    Manera, S
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 627 - 630
  • [32] Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry
    Burmeister, J
    Kota, C
    Maughan, RL
    Waker, AJ
    MEDICAL PHYSICS, 2001, 28 (09) : 1911 - 1925
  • [33] BNCT dosimetry Monte Carlo code system-MCDB and its algorithm
    Laboratory of Computational Physics, Institute of Applied Physics and Computational Mathematics, Beijing 100088, China
    不详
    Qinghua Daxue Xuebao, 2007, SUPPL. 1 (901-906):
  • [34] Computational dosimetry of a simulated combined standard X-Rays and BNCT treatment
    Casal, M. R.
    Herrera, M. S.
    Gonzalez, S. J.
    Minsky, D. M.
    APPLIED RADIATION AND ISOTOPES, 2011, 69 (12) : 1826 - 1829
  • [35] A multicomponent dosimetry system for neutron-gamma mixed field monitoring in BNCT
    Angelucci, M
    Borio, R
    Chiocchini, S
    Degli Esposti, P
    Forini, N
    Salvadori, P
    PHYSICA MEDICA, 1999, 15 (03) : 131 - 136
  • [36] Feasibility of a near-threshold BNCT neutron source based on phantom dosimetry
    Lee, CL
    Kudchadker, RJ
    Harmon, F
    Zhou, XL
    Harker, YD
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 509 - 514
  • [37] Dosimetry chain for the dogs irradiated in the epithermal neutron beam at the Finnish BNCT facility
    Savolainen, S
    Auterinen, I
    Aschan, C
    Hiismäki, P
    Kortesniemi, M
    Kosunen, AK
    Kotiluoto, P
    Lampinen, J
    Seppälä, T
    Serén, T
    Tanner, V
    Toivonen, M
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 1245 - 1250
  • [38] The alanine detector in BNCT dosimetry: Dose response in thermal and epithermal neutron fields
    Schmitz, T.
    Bassler, N.
    Blaickner, M.
    Ziegner, M.
    Hsiao, M. C.
    Liu, Y. H.
    Koivunoro, H.
    Auterinen, I.
    Seren, T.
    Kotiluoto, P.
    Palmans, H.
    Sharpe, P.
    Langguth, P.
    Hampel, G.
    MEDICAL PHYSICS, 2015, 42 (01) : 400 - 411
  • [39] Three dimensional dosimetry in BNCT by NMR analysis of tissue-equivalent phantoms
    Gambarini, G
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 76 - 79
  • [40] Radiation dosimetry in the BNCT patient treatment room at the Brookhaven Medical Research Reactor
    Holden, N. E.
    Reciniello, R. N.
    Hu, J. -P.
    REACTOR DOSIMETRY: 12TH INTERNATIONAL SYMPOSIUM, 2008, 1490 : 130 - 136