Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry

被引:26
|
作者
Burmeister, J
Kota, C
Maughan, RL
Waker, AJ
机构
[1] Harper Hosp, Gershenson Radiat Oncol Ctr, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI 48201 USA
[3] AECL Res, Chalk River Labs, Chalk River, ON K0J 1J0, Canada
关键词
dosimetry; microdosimetry; BNCT; BNCEFNT tissue-equivalent proportional counters;
D O I
10.1118/1.1398303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dual miniature tissue-equivalent proportional counter (TEPC) system has been developed to facilitate microdosimetry for Boron Neutron Capture Therapy (BNCT). This system has been designed specifically to allow the analysis of the single event charged particle spectrum in phantom in high intensity BNCT bean-is and to provide this microdosimetric information with excellent spatial resolution. Paired A-150 and B-10-loaded A-150 TEPCs with 12.3 mm(3) collecting volumes have been constructed. These TEPCs allow more accurate neutron dosimetry than current techniques, offer a direct measure of the boron neutron capture dose, and provide a framework for predicting the biological effectiveness of the absorbed dose. Design aspects and characterization of these detectors are reviewed, along with an exposition of the advantages of microdosimetry using these detectors over conventional dosimetry methods. In addition, the utility of this technique for boron neutron capture enhancement of fast neutron therapy (BNCEFNT) is discussed. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1911 / 1925
页数:15
相关论文
共 50 条
  • [1] BNCT dosimetry performed with a mini twin tissue-equivalent proportional counters (TEPC)
    Moro, D.
    Colautti, P.
    Lollo, M.
    Esposito, J.
    Conte, V.
    De Nardo, L.
    Ferretti, A.
    Ceballos, C.
    [J]. APPLIED RADIATION AND ISOTOPES, 2009, 67 (7-8) : S171 - S174
  • [2] Use of low-pressure tissue equivalent proportional counters for the dosimetry of neutron beams used in BNCT and BNCEFNT
    Kota, C
    Maughan, RL
    Tattam, D
    Beynon, TD
    [J]. MEDICAL PHYSICS, 2000, 27 (03) : 535 - 548
  • [3] Characterization of miniature tissue-equivalent proportional counters for neutron radiotherapy applications
    Burmeister, J
    Kota, C
    Maughan, RL
    Waker, AJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (10): : 1633 - 1645
  • [4] Design of tissue-equivalent proportional counters
    Kliauga, P
    Waker, AJ
    Barthe, J
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 309 - 322
  • [5] Paired miniature tissue-equivalent proportional counters for dosimetry in high flux epithermal neutron capture therapy beams
    Burmeister, J
    Kota, C
    Maughan, RL
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 606 - 610
  • [6] DOSIMETRY IN MIXED NEUTRON PHOTON FIELDS WITH TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS
    SCHREWE, UJ
    BREDE, HJ
    DIETZE, G
    [J]. RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 41 - 45
  • [7] Tissue-equivalent proportional counters in radiation protection
    McDonald, JC
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 77 (03) : 147 - 149
  • [8] Numerical modelling of tissue-equivalent proportional counters
    Segur, P
    Olko, P
    Colautti, P
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 323 - 350
  • [9] Operation and application of tissue-equivalent proportional counters
    Gerdung, S
    Pihet, P
    Grindborg, JE
    Roos, H
    Schrewe, UJ
    Schuhmacher, H
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 381 - 404