Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT dosimetry

被引:26
|
作者
Burmeister, J
Kota, C
Maughan, RL
Waker, AJ
机构
[1] Harper Hosp, Gershenson Radiat Oncol Ctr, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI 48201 USA
[3] AECL Res, Chalk River Labs, Chalk River, ON K0J 1J0, Canada
关键词
dosimetry; microdosimetry; BNCT; BNCEFNT tissue-equivalent proportional counters;
D O I
10.1118/1.1398303
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A dual miniature tissue-equivalent proportional counter (TEPC) system has been developed to facilitate microdosimetry for Boron Neutron Capture Therapy (BNCT). This system has been designed specifically to allow the analysis of the single event charged particle spectrum in phantom in high intensity BNCT bean-is and to provide this microdosimetric information with excellent spatial resolution. Paired A-150 and B-10-loaded A-150 TEPCs with 12.3 mm(3) collecting volumes have been constructed. These TEPCs allow more accurate neutron dosimetry than current techniques, offer a direct measure of the boron neutron capture dose, and provide a framework for predicting the biological effectiveness of the absorbed dose. Design aspects and characterization of these detectors are reviewed, along with an exposition of the advantages of microdosimetry using these detectors over conventional dosimetry methods. In addition, the utility of this technique for boron neutron capture enhancement of fast neutron therapy (BNCEFNT) is discussed. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:1911 / 1925
页数:15
相关论文
共 50 条
  • [31] Dosimetry of the boron neutron capture reaction for BNCT and BNCEFNT
    Jay Burmeister
    Chandrasekhar Kota
    Richard L. Maughan
    [J]. Strahlentherapie und Onkologie, 1999, 175 : 115 - 118
  • [32] EXPERIMENTAL-STUDY OF THE DOSE EQUIVALENT RESPONSE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS TO LOW-ENERGY NEUTRONS
    ALBERTS, WG
    BUHLER, G
    DUDLER, R
    MENZEL, HG
    SCHUHMACHER, H
    [J]. RADIATION PROTECTION DOSIMETRY, 1984, 9 (03) : 211 - 214
  • [33] TISSUE-EQUIVALENT DEVICES FOR MIXED FIELD DOSIMETRY
    LUCAS, AC
    [J]. HEALTH PHYSICS, 1970, 19 (02): : 328 - +
  • [34] Optimized design of tissue-equivalent proportional counter
    Zhang, Wei-Hua
    Wang, Zhi-Qiang
    Xiao, Xue-Fu
    Liu, Yi-Na
    Li, Chun-Juan
    Luo, Hai-Long
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2014, 48 (05): : 930 - 933
  • [35] FLUKA simulations of the response of tissue-equivalent proportional counters to ion beams for applications in hadron therapy and space
    Bohlen, T. T.
    Dosanjh, M.
    Ferrari, A.
    Gudowska, I.
    Mairani, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (20): : 6545 - 6561
  • [36] ON THE USE OF TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS IN HIGH-ENERGY STRAY RADIATION-FIELDS
    AROUA, A
    HOFERT, M
    SANNIKOV, AV
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 59 (01) : 49 - 53
  • [37] TISSUE-EQUIVALENT MATERIALS FOR HUMAN PHANTOMS AND DOSIMETRY
    FRIGERIO, NA
    LAVOY, LL
    STOWE, RS
    [J]. RADIATION RESEARCH, 1976, 67 (03) : 615 - 615
  • [38] A NEW CONCEPT OF A HIGH-SENSITIVITY TISSUE-EQUIVALENT PROPORTIONAL COUNTER FOR INDIVIDUAL NEUTRON DOSIMETRY
    BOUTRUCHE, B
    BORDY, JM
    BARTHE, J
    SEGUR, P
    PORTAL, G
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 52 (1-4) : 335 - 338
  • [39] Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy
    Farah, J.
    De Saint-Hubert, M.
    Mojzeszek, N.
    Chiriotti, S.
    Gryzinski, M.
    Ploc, O.
    Trompier, F.
    Turek, K.
    Vanhavere, F.
    Olko, P.
    [J]. RADIATION MEASUREMENTS, 2017, 96 : 42 - 52
  • [40] DETERMINATION OF DOSE EQUIVALENT WITH TISSUE EQUIVALENT PROPORTIONAL-COUNTERS
    DIETZE, G
    MENZEL, HG
    SCHUHMACHER, H
    [J]. RADIATION PROTECTION DOSIMETRY, 1989, 28 (1-2) : 77 - 81