Microfluidic paper-based analytical device for convenient use in measurement of iodate in table salt and irrigation water

被引:15
|
作者
Duangdeewong, Chomphunud [1 ,2 ]
Sitanurak, Jirayu [3 ,4 ,5 ]
Wilairat, Prapin [3 ,4 ]
Nacapricha, Duangjai [3 ,4 ,5 ]
Teerasong, Saowapak [1 ,2 ,5 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Fac Sci, Dept Chem, Bangkok 10520, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Fac Sci, Appl Analyt Chem Res Unit, Bangkok 10520, Thailand
[3] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[4] Mahidol Univ, Fac Sci, Ctr Excellence Innovat Chem, Bangkok 10400, Thailand
[5] Flow Innovat Res Sci & Technol Labs FIRST Labs, Bangkok, Thailand
关键词
Iodate; Microfluidic paper-based analytical device; Griess reaction; Salt; Irrigation water; IODIZED EDIBLE SALT; COLORIMETRIC DETERMINATION; SPECTROPHOTOMETRIC DETERMINATION; IODINE; NITRITE; UV;
D O I
10.1016/j.microc.2019.104447
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a convenient microfluidic paper-based analytical device (mu PAD) for the determination of iodate. The mu PAD was fabricated using an ink-stamp with a simple circle design. Colorimetric detection of iodate employs the oxidation of hydroxylamine by the iodate to generate nitrite which reacts with the Griess reagent producing an intense magenta color. The images were recorded by a digital camera, and converted to a green scale color intensity by ImageJ. Calibration of iodate was linear in the range of 50-400 mg L-1 with a detection limit of 38.1 mg L-1. With such a wide linear range, the method can be applied to various kinds of samples with the entire process completed in 50 s. Good precision of measurement was obtained (<2 %RSD). Iodate levels were determined using the mu PADs in table salt and irrigation water samples. The measured concentrations of the samples correlated well with the values as found by the standard iodometric titration (no statistical difference at a 95% confidence level). The developed device is simple with easy fabrication and rapid operation. It is portable and cost-effective and therefore suitable for quality control of iodate levels in the manufacturing and agricultural industries.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] A New Paper-Based Microfluidic Device for Improved Detection of Nitrate in Water
    Charbaji, Amer
    Heidari-Bafroui, Hojat
    Anagnostopoulos, Constantine
    Faghri, Mohammad
    SENSORS, 2021, 21 (01) : 1 - 15
  • [32] Microfluidic Paper-based Device for Medicinal Diagnosis
    Lomae, Atchara
    Preechakasedkit, Pattarachaya
    Teekayupak, Kanyapat
    Panraksa, Yosita
    Yukird, Jutiporn
    Chailapakul, Orawon
    Ruecha, Nipapan
    CURRENT TOPICS IN MEDICINAL CHEMISTRY, 2022, 22 (27) : 2282 - 2313
  • [33] Microfluidic paper-based analytical device for measurement of pH using as sensor red cabbage anthocyanins and gum arabic
    Cortes-Avendano, Paola
    Macavilca, Edwin A.
    Ponce-Rosas, Fortunato C.
    Murillo-Baca, Silvia M.
    Quispe-Neyra, Juan
    Alvarado-Zambrano, Fredy
    Condezo-Hoyos, Luis
    FOOD CHEMISTRY, 2025, 462
  • [34] A PORTABLE MICROFLUIDIC PAPER-BASED DEVICE FOR ELISA
    Liu, X. Y.
    Cheng, C. M.
    Martinez, A. W.
    Mirica, K. A.
    Li, X. J.
    Phillips, S. T.
    Mascarenas, M.
    Whitesides, G. M.
    2011 IEEE 24TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS), 2011, : 75 - 78
  • [35] Determination of phosphorus in water and chemical fertilizer samples using a simple drawing microfluidic paper-based analytical device
    Piyawan Phansi
    Sirinthip Janthama
    Víctor Cerdà
    Duangjai Nacapricha
    Analytical Sciences, 2022, 38 : 1323 - 1332
  • [36] Dual Chromatic Laser-Printed Microfluidic Paper-Based Analytical Device (μPAD) for the Detection of Atrazine in Water
    Moulahoum, Hichem
    ACS OMEGA, 2023, 8 (44): : 41194 - 41203
  • [37] Determination of phosphorus in water and chemical fertilizer samples using a simple drawing microfluidic paper-based analytical device
    Phansi, Piyawan
    Janthama, Sirinthip
    Cerda, Victor
    Nacapricha, Duangjai
    ANALYTICAL SCIENCES, 2022, 38 (10) : 1323 - 1332
  • [38] Signal Amplification in a Microfluidic Paper-based Analytical Device (μ-PAD) by Confinement of the Fluidic Flow
    Choi, Seoyeon
    Lee, Jung-Hyun
    Kwak, Bong Seop
    Kim, Young Woo
    Lee, Joon Sang
    Choi, Jong-Soon
    Jung, Hyo-Il
    BIOCHIP JOURNAL, 2015, 9 (02) : 116 - 123
  • [39] Semi-quantitative microfluidic paper-based analytical device for ionic silica detection
    Ogawa, Mami
    Katoh, Aya
    Matsubara, Ryuichi
    Kondo, Haruka
    Otsuka, Mizuki
    Sawatsubashi, Tetsuya
    Hiruta, Yuki
    Citterio, Daniel
    ANALYTICAL SCIENCES, 2023, 39 (08) : 1361 - 1370
  • [40] Signal amplification in a microfluidic paper-based analytical device (µ-PAD) by confinement of the fluidic flow
    Seoyeon Choi
    Jung-Hyun Lee
    Bong Seop Kwak
    Young Woo Kim
    Joon Sang Lee
    Jong-Soon Choi
    Hyo-Il Jung
    BioChip Journal, 2015, 9 : 116 - 123