Microfluidic paper-based analytical device for convenient use in measurement of iodate in table salt and irrigation water

被引:15
|
作者
Duangdeewong, Chomphunud [1 ,2 ]
Sitanurak, Jirayu [3 ,4 ,5 ]
Wilairat, Prapin [3 ,4 ]
Nacapricha, Duangjai [3 ,4 ,5 ]
Teerasong, Saowapak [1 ,2 ,5 ]
机构
[1] King Mongkuts Inst Technol Ladkrabang, Fac Sci, Dept Chem, Bangkok 10520, Thailand
[2] King Mongkuts Inst Technol Ladkrabang, Fac Sci, Appl Analyt Chem Res Unit, Bangkok 10520, Thailand
[3] Mahidol Univ, Fac Sci, Dept Chem, Bangkok 10400, Thailand
[4] Mahidol Univ, Fac Sci, Ctr Excellence Innovat Chem, Bangkok 10400, Thailand
[5] Flow Innovat Res Sci & Technol Labs FIRST Labs, Bangkok, Thailand
关键词
Iodate; Microfluidic paper-based analytical device; Griess reaction; Salt; Irrigation water; IODIZED EDIBLE SALT; COLORIMETRIC DETERMINATION; SPECTROPHOTOMETRIC DETERMINATION; IODINE; NITRITE; UV;
D O I
10.1016/j.microc.2019.104447
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report a convenient microfluidic paper-based analytical device (mu PAD) for the determination of iodate. The mu PAD was fabricated using an ink-stamp with a simple circle design. Colorimetric detection of iodate employs the oxidation of hydroxylamine by the iodate to generate nitrite which reacts with the Griess reagent producing an intense magenta color. The images were recorded by a digital camera, and converted to a green scale color intensity by ImageJ. Calibration of iodate was linear in the range of 50-400 mg L-1 with a detection limit of 38.1 mg L-1. With such a wide linear range, the method can be applied to various kinds of samples with the entire process completed in 50 s. Good precision of measurement was obtained (<2 %RSD). Iodate levels were determined using the mu PADs in table salt and irrigation water samples. The measured concentrations of the samples correlated well with the values as found by the standard iodometric titration (no statistical difference at a 95% confidence level). The developed device is simple with easy fabrication and rapid operation. It is portable and cost-effective and therefore suitable for quality control of iodate levels in the manufacturing and agricultural industries.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Development of a microfluidic paper-based analytical device for magnesium determination in saliva samples
    Aguiar, Juliana I. S.
    Silva, Mafalda T. S.
    Ferreira, Helena A. G.
    Pinto, Elisabete C. B.
    Vasconcelos, Marta W.
    Rangel, Antonio O. S. S.
    Mesquita, Raquel B. R.
    TALANTA OPEN, 2022, 6
  • [22] A Microfluidic Paper-Based Analytical Device for Type-II Pyrethroid Targets in an Environmental Water Sample
    Pengpumkiat, Sumate
    Nammoonnoy, Jintana
    Wongsakoonkan, Watcharaporn
    Konthonbut, Pajaree
    Kongtip, Pornpimol
    SENSORS, 2020, 20 (15) : 1 - 15
  • [23] New microfluidic paper-based analytical device for iron determination in urine samples
    Francisca T. S. M. Ferreira
    Karina A. Catalão
    Raquel B. R. Mesquita
    António O. S. S. Rangel
    Analytical and Bioanalytical Chemistry, 2021, 413 : 7463 - 7472
  • [24] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Taghizadeh-Behbahani, Maryam
    Hemmateenejad, Bahram
    Shamsipur, Mojtaba
    CHEMICAL PAPERS, 2018, 72 (05) : 1239 - 1247
  • [25] New microfluidic paper-based analytical device for iron determination in urine samples
    Ferreira, Francisca T. S. M.
    Catalao, Karina A.
    Mesquita, Raquel B. R.
    Rangel, Antonio O. S. S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (30) : 7463 - 7472
  • [26] Microfluidic paper-based analytical devices: from POCKET to paper-based ELISA
    Martinez, Andres W.
    BIOANALYSIS, 2011, 3 (23) : 2589 - 2592
  • [27] A portable microfluidic paper-based analytical device for blood detection and typing assay
    Ansari, Niha
    Trambadiya, Nehal
    Lodha, Anand
    Menon, S. K.
    AUSTRALIAN JOURNAL OF FORENSIC SCIENCES, 2021, 53 (04) : 407 - 418
  • [28] A microfluidic paper-based analytical device for iodometric titration of ascorbic acid and dopamine
    Heidary, Oldouz
    Akhond, Morteza
    Hemmateenejad, Bahram
    MICROCHEMICAL JOURNAL, 2022, 182
  • [29] Colorimetric determination of acidity constant using a paper-based microfluidic analytical device
    Maryam Taghizadeh-Behbahani
    Bahram Hemmateenejad
    Mojtaba Shamsipur
    Chemical Papers, 2018, 72 : 1239 - 1247
  • [30] Advances in Microfluidic Paper-Based Analytical Devices for Food and Water Analysis
    Alamo Busa, Lori Shayne
    Mohammadi, Saeed
    Maeki, Masatoshi
    Ishida, Akihiko
    Tani, Hirofumi
    Tokeshi, Manabu
    MICROMACHINES, 2016, 7 (05):