Characterization of focal liver lesions with conventional color Doppler and power Doppler sonography

被引:0
|
作者
Strunk, H [1 ]
Stuckmann, G [1 ]
Frohlich, E [1 ]
Textor, J [1 ]
Wilhelm, K [1 ]
Hortling, N [1 ]
Gallkowski, U [1 ]
机构
[1] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
关键词
liver; neoplasms; ultrasound; (US); Doppler studies; power-Doppler;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To compare conventional color Doppler and power Doppler sonography for characterization of liver lesions on the basis of the flow pattern. Materials and methods: 62 patients with 68 liver lesions (20 hepatocellular carcinomas (HCCs). 18 metastases, 1 cholangiocarcinoma, 18 hemangiomas, 4 focal nodular hyperplasias (FNH). 4 focal fatty infiltration, 3 inflammatory lesions) were evaluated prospectively. Color and Power Doppler images were analyzed by two radiologists and one gastroenterologist who subjectively classified the distributation (peripheral, central, diffuse) and amount (no, minimal, moderate and strong) of now pattern in each sonographic examination. Histologic verification was obtained ii, all liver lesions except in hemangiomas, where MR-imaging and in one FNH, where scintigraphy was regarded sufficient prove. Results: Overall, power Doppler sonography was superior to color Doppler sonography in 22 liver lesions. With power Doppler previously visible flow was enhanced in 9 patients in 13 lesions flow was detected, which was not seen before. 31 tumours (12 hemangiomas, 2 inflammatory lesions, 2 focal fatty infiltration, 1 FNH, 8 metastases, 6 HCCs) did not show a flow signal in either mode. Flow signals were detected with conventional color Doppler/power Doppler in 0/1 hemangioma centrally: and peripherally, 1/2 hemangiomas only peripherally, 0/2 hemangiomas only centrally, 1/0 FNH central and peripherally, 1/0 FNH only peripherally 1/0 FNH only centrally, 3/0 metastases centrally and peripherally, 1/3 metastases only peripherally; 1/2 metastases only centrally, 6/0 HCCs centrally and metastases only peripherally; 1/2 metastases; only centrally, 6/0 HCCs centrally and peripherally, 4/0 HCCs only peripherally, 3/1 HCCs only centrally. Conclusion: Power Doppler sonography is more sensitive than conventional color Doppler sonography in the depiction of tumor vascularity. Intratumoral flow signals favour a malignant tumour. The absence of now signals is a frequent finding in benign lesions but do not rule out malignancy.
引用
收藏
页码:63 / +
页数:7
相关论文
共 50 条
  • [31] Evaluation of breast lesions by power Doppler sonography
    Milz, P
    Lienemann, A
    Kessler, M
    Reiser, M
    EUROPEAN RADIOLOGY, 2001, 11 (04) : 547 - 554
  • [32] Contrast-enhanced power Doppler sonography: Improved detection of characteristic flow patterns in focal liver lesions
    Hosten, N
    Puls, R
    Lemke, AJ
    Steger, W
    Zendel, W
    Zwicker, C
    Felix, R
    JOURNAL OF CLINICAL ULTRASOUND, 1999, 27 (03) : 107 - 115
  • [33] Evaluation of breast lesions by power Doppler sonography
    P. Milz
    A. Lienemann
    M. Kessler
    M. Reiser
    European Radiology, 2001, 11 : 547 - 554
  • [34] Color Doppler sonography
    Pedregal, CJ
    Blanco, JAP
    Tutor, AG
    Castano, GD
    Delgado, MS
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 1995, 87 (12) : 907 - 908
  • [35] Color Doppler sonography
    Giuseppetti, GM
    Baldassarre, S
    Marconi, E
    EUROPEAN JOURNAL OF RADIOLOGY, 1998, 27 : S254 - S258
  • [36] Characterization of solid liver lesions with color and pulsed Doppler imaging
    González-Añón, M
    Cervera-Deval, J
    García-Vila, JH
    Bordón-Ferré, F
    Ambit-Capdevila, S
    Piqueras-Olmeda, R
    Jornet-Fayos, J
    Gil-Sánchez, S
    Marco-Domenech, SF
    Cortés-Vizcaíno, V
    ABDOMINAL IMAGING, 1999, 24 (02): : 137 - 143
  • [37] Characterization of solid liver lesions with color and pulsed Doppler imaging
    M. González-Añón
    J. Cervera-Deval
    J. H. García-Vila
    F. Bordón-Ferré
    S. Ambit-Capdevila
    R. Piqueras-Olmeda
    J. Jornet-Fayos
    S. Gil-Sánchez
    S. F. Marco-Domenech
    V. Cortés-Vizcaíno
    Abdominal Imaging, 1999, 24 : 137 - 143
  • [38] Conventional color Doppler velocity sonography versus color Doppler energy sonography for the diagnosis of acute experimental torsion of the spermatic cord
    Lee, FT
    Winter, DB
    Madsen, FA
    Zagzebski, JA
    Pozniak, MA
    Chosy, SG
    Scanlan, KA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (03) : 785 - 790
  • [39] Ultrasonographic Detection of Vascularity of Focal Breast Lesions: Microvascular Imaging Versus Conventional Color and Power Doppler Imaging
    Bartolotta, Tommaso Vincenzo
    Orlando, Alessia Angela Maria
    Schillaci, Maria Ilenia
    Spatafora, Luigi
    Di Marco, Mariangela
    Matranga, Domenica
    Firenze, Alberto
    Cirino, Alessandra
    Ienzi, Raffaele
    ULTRASONIC IMAGING, 2021, 43 (05) : 273 - 281
  • [40] HEPATIC FOCAL NODULAR HYPERPLASIA - FINDINGS WITH COLOR DOPPLER SONOGRAPHY
    LEARCH, TJ
    RALLS, PW
    JOHNSON, MB
    JEFFREY, RB
    NINOMURCIA, M
    LEE, KP
    RADIN, DR
    JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (09) : 541 - 544