Characterization of focal liver lesions with conventional color Doppler and power Doppler sonography

被引:0
|
作者
Strunk, H [1 ]
Stuckmann, G [1 ]
Frohlich, E [1 ]
Textor, J [1 ]
Wilhelm, K [1 ]
Hortling, N [1 ]
Gallkowski, U [1 ]
机构
[1] Univ Bonn, Radiol Klin, D-53105 Bonn, Germany
关键词
liver; neoplasms; ultrasound; (US); Doppler studies; power-Doppler;
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Purpose: To compare conventional color Doppler and power Doppler sonography for characterization of liver lesions on the basis of the flow pattern. Materials and methods: 62 patients with 68 liver lesions (20 hepatocellular carcinomas (HCCs). 18 metastases, 1 cholangiocarcinoma, 18 hemangiomas, 4 focal nodular hyperplasias (FNH). 4 focal fatty infiltration, 3 inflammatory lesions) were evaluated prospectively. Color and Power Doppler images were analyzed by two radiologists and one gastroenterologist who subjectively classified the distributation (peripheral, central, diffuse) and amount (no, minimal, moderate and strong) of now pattern in each sonographic examination. Histologic verification was obtained ii, all liver lesions except in hemangiomas, where MR-imaging and in one FNH, where scintigraphy was regarded sufficient prove. Results: Overall, power Doppler sonography was superior to color Doppler sonography in 22 liver lesions. With power Doppler previously visible flow was enhanced in 9 patients in 13 lesions flow was detected, which was not seen before. 31 tumours (12 hemangiomas, 2 inflammatory lesions, 2 focal fatty infiltration, 1 FNH, 8 metastases, 6 HCCs) did not show a flow signal in either mode. Flow signals were detected with conventional color Doppler/power Doppler in 0/1 hemangioma centrally: and peripherally, 1/2 hemangiomas only peripherally, 0/2 hemangiomas only centrally, 1/0 FNH central and peripherally, 1/0 FNH only peripherally 1/0 FNH only centrally, 3/0 metastases centrally and peripherally, 1/3 metastases only peripherally; 1/2 metastases only centrally, 6/0 HCCs centrally and metastases only peripherally; 1/2 metastases; only centrally, 6/0 HCCs centrally and peripherally, 4/0 HCCs only peripherally, 3/1 HCCs only centrally. Conclusion: Power Doppler sonography is more sensitive than conventional color Doppler sonography in the depiction of tumor vascularity. Intratumoral flow signals favour a malignant tumour. The absence of now signals is a frequent finding in benign lesions but do not rule out malignancy.
引用
收藏
页码:63 / +
页数:7
相关论文
共 50 条
  • [21] POWER VERSUS CONVENTIONAL COLOR DOPPLER SONOGRAPHY - COMPARISON IN THE DEPICTION OF INTRATUMORAL VASCULATURE OF LIVER-TUMORS
    CHOI, BI
    KIM, TK
    HAN, JK
    CHUNG, JW
    PARK, JH
    HAN, MC
    RADIOLOGY, 1995, 197 : 400 - 400
  • [22] Color Doppler and contrast media in the evaluation of the treatment of focal liver lesions
    Lencioni, R.
    Cioni, D.
    Bartolozzi, C.
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [23] Focal liver lesions: Doppler ultrasound
    Hosten, N
    Puls, R
    Bechstein, WO
    Felix, R
    EUROPEAN RADIOLOGY, 1999, 9 (03) : 428 - 435
  • [24] Focal liver lesions: Doppler ultrasound
    N. Hosten
    R. Puls
    W. O. Bechstein
    R. Felix
    European Radiology, 1999, 9 : 428 - 435
  • [25] COLOR DOPPLER SONOGRAPHY OF VASCULAR MALFORMATIONS OF THE LIVER
    SHAPIRO, RS
    WINSBERG, F
    STANCATOPASIK, A
    STERLING, KM
    JOURNAL OF ULTRASOUND IN MEDICINE, 1993, 12 (06) : 343 - 348
  • [26] Unenhanced and enhanced power Doppler sonography for characterising liver lesions.
    Strunk, H
    Stuckmann, G
    Frohlich, E
    Textor, J
    Wilhelm, K
    Hortling, N
    Remig, J
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1998, 168 (04): : 344 - 351
  • [27] POWER VERSUS COLOR DOPPLER US OF FOCAL HEPATIC-LESIONS
    KIM, TK
    CHOI, BI
    HAN, JK
    KIM, SH
    CHUNG, JW
    HAN, MC
    RADIOLOGY, 1995, 197 : 512 - 513
  • [28] Differential diagnosis of lymphadenopathy: power Doppler vs color Doppler sonography
    A. Tschammler
    M. Beer
    D. Hahn
    European Radiology, 2002, 12 : 1794 - 1799
  • [29] Differential diagnosis of lymphadenopathy: power Doppler vs color Doppler sonography
    Tschammler, A
    Beer, M
    Hahn, D
    EUROPEAN RADIOLOGY, 2002, 12 (07) : 1794 - 1799
  • [30] Color and Power Doppler Sonography for Pneumothorax Detection
    Richards, John R.
    Awrey, Julianne M.
    Medeiros, Sarah E.
    McGahan, John P.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (10) : 2143 - 2147