Need for Standardization: Influence of Artificial Canal Size on Cyclic Fatigue Tests of Endodontic Instruments

被引:9
|
作者
Buerklein, Sebastian [1 ]
Massmann, Paul [2 ]
Donnermeyer, David [2 ]
Tegtmeyer, Karsten [2 ]
Schaefer, Edgar [1 ]
机构
[1] Westphalian Wilhelms Univ, Cent Interdisciplinary Ambulance Sch Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
[2] Westphalian Wilhelms Univ, Dept Periodontol & Operat Dent, Albert Schweitzer Campus 1,Bldg W 30, D-48149 Munster, Germany
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 11期
关键词
artificial canal; congruence; body temperature; dynamic fatigue tests; fracture resistance; ISO; nickel-titanium instruments; NICKEL-TITANIUM ROTARY; ROTATIONAL SPEED; RESISTANCE; SEPARATION; FILES; TEMPERATURE; FRACTURE; DEFECTS;
D O I
10.3390/app11114950
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The aim was to evaluate the influence of artificial canal size on the results of cyclic fatigue tests for endodontic instruments. Dynamic cyclic fatigue at body temperature using continuous tapered nickel-titanium F6-SkyTaper instruments (Komet, Lemgo, Germany), size 25/.06 with an amplitude of 3 mm, was tested in four different simulated root canals: (A) size of the instrument +0.02 mm (within the tolerances of the instruments); (B) +0.05 mm; (C) +0.10 mm; (D) parallel tube with 1.25 mm in diameter. The artificial canals (angle of curvature 60 degrees, radius 5.0 mm, center of curvature 5.0 mm) were produced by a LASER-melting technique. Time and cycles to fracture, and lengths of the fractured instruments were recorded and statistically analyzed (Student-Newman-Keuls; Kruskal-Wallis test). Time to fracture significantly increased with increasing size of the artificial canals in the following order: A < B, C < D (p < 0.05). Length of separated instruments continuously decreased with increasing canal sizes. The parallel tube produced the significantly shortest fragments (p < 0.05). Within the limitations of this study, dynamic cyclic fatigue of endodontic instruments depends on the congruency of the instruments' dimensions with that of the artificial canals. In future cyclic fatigue testing, due to the closer match of canal and instrument parameters, it is necessary to adjust the artificial canal sizes to the size of the instruments within the manufacturing tolerances of the instruments.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Measurement of the trajectory of different NiTi rotary instruments in an artificial canal specifically designed for cyclic fatigue tests
    Plotino, Gianluca
    Grande, Nicola M.
    Cordaro, Massimo
    Testarelli, Luca
    Gambarini, Gianluca
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 108 (03): : E152 - E156
  • [2] Cyclic fatigue of endodontic nickel titanium rotary instruments: Static and dynamic tests
    Li, UM
    Lee, BS
    Shih, CT
    Lan, WH
    Lin, CP
    JOURNAL OF ENDODONTICS, 2002, 28 (06) : 448 - 451
  • [3] Cyclic fatigue of instruments for endodontic glide path
    Gambarini, Gianluca
    Plotino, Gianluca
    Sannino, GianPaolo
    Grande, Nicola Maria
    Giansiracusa, Alessio
    Piasecki, Lucila
    da Silva Neto, Ulisses Xavier
    Al-Sudani, Dina
    Testarelli, Luca
    ODONTOLOGY, 2015, 103 (01) : 56 - 60
  • [4] Cyclic fatigue of instruments for endodontic glide path
    Gianluca Gambarini
    Gianluca Plotino
    GianPaolo Sannino
    Nicola Maria Grande
    Alessio Giansiracusa
    Lucila Piasecki
    Ulisses Xavier da Silva Neto
    Dina Al-Sudani
    Luca Testarelli
    Odontology, 2015, 103 : 56 - 60
  • [5] Influence of curvature location along an artificial canal on cyclic fatigue of a rotary nickel-titanium endodontic instrument
    Lopes, Helio Pereira
    Maia Chiesa, Wanderson Miguel
    Correia, Norbi Rodrigues
    de Souza Navegante, Nubia Carvalho
    Elias, Carlos Nelson
    Lima Moreira, Edson Jorge
    Cabral Chiesa, Bianca Esther
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2011, 111 (06): : 792 - 796
  • [6] Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?
    Emmanuel João Nogueira Leal Silva
    Rafael Santos Attademo
    Marcia Cristina Dutra da Silva
    Karem Paula Pinto
    Henrique dos Santos Antunes
    Victor Talarico Leal Vieira
    Clinical Oral Investigations, 2021, 25 : 3691 - 3698
  • [7] Does the type of endodontic access influence in the cyclic fatigue resistance of reciprocating instruments?
    Nogueira Leal Silva, Emmanuel Joao
    Attademo, Rafael Santos
    Dutra da Silva, Marcia Cristina
    Pinto, Karem Paula
    Antunes, Henrique dos Santos
    Leal Vieira, Victor Talarico
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (06) : 3691 - 3698
  • [8] Influence of size and taper of artificial canals on the trajectory of NiTi rotary instruments in cyclic fatigue studies
    Plotino, Gianluca
    Grande, Nicola M.
    Mazza, Ciro
    Petrovic, Renata
    Testarelli, Luca
    Gambarini, Gianluca
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 109 (01): : E60 - E66
  • [9] Cyclic fatigue resistance of five rotary endodontic instruments
    Chaveli-Diaz, B.
    Forner, L.
    Llena, C.
    Madureira, R.
    Tadeu, F.
    BIODENTAL ENGINEERING III, 2014, : 89 - 92
  • [10] Influence of Rotational Speed on the Cyclic Fatigue of Rotary Nickel-Titanium Endodontic Instruments
    Lopes, Helio P.
    Ferreira, Alessandra A. P.
    Elias, Carlos N.
    Moreira, Edson J. L.
    Machado de Oliveira, Julio C.
    Siqueira, Jose F., Jr.
    JOURNAL OF ENDODONTICS, 2009, 35 (07) : 1013 - 1016