Developing a dual energy x-ray absorptiometry (DEXA) system using SrI2:Eu2+ coupled to silicon photomultiplier (SiPM)

被引:0
|
作者
Matei, Liviu [1 ]
Groza, Michael [2 ]
Gomez, Michelle [1 ]
Espinoza, Kricia Ruano [1 ]
Buliga, Vladimir [1 ]
Burger, Arnold [1 ]
机构
[1] Fisk Univ, Dept Phys, 1000 17th Ave North, Nashville, TN 37208 USA
[2] 2716 E Castleberg Loop, Nampa, ID 83686 USA
基金
美国国家科学基金会;
关键词
Bone Mineral Density; SrI2:Eu2+; Silicon Photomultiplier; Osteoporosis;
D O I
10.1117/12.2567674
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents the evaluation of an alternative solution for detectors of dual energy x-ray absorptiometry systems. Bone mineral density (BMD) evaluation tools are crucial to the proper diagnosis of osteoporosis. The commercially available DEXA systems utilize CZT as the detector of the small dose of ionizing radiation passing through the area of interest. Our paper presents a novel Strontium Iodide doped with Europium (SrI2:Eu2+) scintillator crystal coupled to a Silicon Photomultiplier (SiPM) array as a less expensive alternative to CZT detector. Dual energy (60 keV and 122 keV) exposure was used for BMD measurements of a bone phantoms containing CaHPO4 to mimic bone and resin to mimic soft tissue. Calibration curves was determined for both BMD and for thickness measurements, validated by "unknown" phantoms. Both calibration curves lead to decreased errors compared to commercially available systems.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Meat tenderness evaluation using dual energy X-ray absorptiometry (DEXA)
    Kroger, C.
    Bartle, C. M.
    West, J. G.
    Purchas, R. W.
    Devine, C. E.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2006, 54 (02) : 93 - 100
  • [2] Wool base determination using dual energy X-ray absorptiometry (DEXA)
    Kroger, Chris
    Bartle, C. Murray
    West, John G.
    van Rensburg, Brendon
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (12) : 1604 - 1612
  • [3] SrI2:Eu2+-Scintillators for Spectroscopy and X-Ray Imaging Applications
    Alaribe, Leonard
    Disch, Christian
    Fauler, Alex
    Engels, Ralf
    Keller, Egbert
    Cecilia, Angelica
    Rolo, Tomy dos Santos
    Hamann, Elias
    Fiederle, Michael
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2193 - 2195
  • [4] Mesurement of bone density in adult cats using Dual-Energy X-ray Absorptiometry (DEXA)
    Schmidt, J
    Fehr, M
    Viguier, E
    KLEINTIERPRAXIS, 2006, 51 (04): : 205 - 209
  • [5] THE EFFECTIVENESS OF LEAN BODY MASS ANALYSIS USING DUAL ENERGY X-RAY ABSORPTIOMETRY (DEXA) FOR DIAGNOSIS OF SARCOPENIA
    Kim, S. Y.
    VALUE IN HEALTH, 2016, 19 (07) : A915 - A915
  • [6] A prototype rapid dual energy X-ray absorptiometry (DEXA) system can predict the CT composition of beef carcases
    Calnan, H.
    Williams, A.
    Peterse, J.
    Starling, S.
    Cook, J.
    Connaughton, S.
    Gardner, G. E.
    MEAT SCIENCE, 2021, 173
  • [7] A Comparison of Nutrient Accretion Using Energy Balance (Eb) Studies and Dual Emmission X-Ray Absorptiometry (DEXA) 1560
    Jeffrey Perring
    Richard J Cooke
    Marjorie Henderson
    Arthur Euler
    Pediatric Research, 1998, 43 (Suppl 4) : 266 - 266
  • [8] The measurement of muscle volume of the patients with neuromuscular disorders using CT and dual-energy X-ray absorptiometry (DEXA)
    Konagaya, M.
    Tanaka, N.
    Nakayama, T.
    Motoyoshi, Y.
    Kawai, M.
    Kuru, S.
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2009, 285 : S304 - S304
  • [9] Measurement of hand bone mineral density in early rheumatoid arthritis using dual energy x-ray absorptiometry (DEXA)
    Hill, CL
    Cleland, LG
    Schultz, C
    Chatterton, BE
    Pile, KD
    ARTHRITIS AND RHEUMATISM, 1997, 40 (09): : 1756 - 1756
  • [10] Bioimpedance analysis (BIA), dual energy X-ray absorptiometry (DEXA) and nutritional characteristics in myotonic dystrophy type 2 (DM2) patients
    Frezza, E.
    Cintoni, M.
    Pulcini, G.
    Greco, G.
    Palombi, C.
    Tammam, G.
    Salvia, M.
    De Lorenzo, A.
    Massa, R.
    EUROPEAN JOURNAL OF NEUROLOGY, 2020, 27 : 220 - 220