The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials

被引:12
|
作者
Nassar, Usama [1 ]
Flores-Mir, Carlos [1 ]
Heo, Giseon [1 ]
Torrealba, Ysidora [1 ]
机构
[1] Univ Alberta, Dept Dent, Fac Med & Dent, 5527 ECHA, Edmonton, AB T6G 1C9, Canada
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2017年 / 9卷 / 03期
关键词
Impression material; Dimensional stability; Disinfectant; VPES; Prolonged storage; SURFACE DETAIL REPRODUCTION; ADDITION SILICONE; ACCURACY;
D O I
10.4047/jap.2017.9.3.182
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PURPOSE. Vinyl polyether silicone (VPES) has a different composition from other elastomeric impression materials as it combines vinyl polysiloxane (VPS) and polyether (PE). Therefore, it is important to study its properties and behavior under different test conditions. This study investigated the dimensional stability of 5 VPES consistencies when stored for up to 2 weeks, with and without using a standard disinfection procedure. MATERIALS AND METHODS. 40 discs of each VPES consistency (total 200) were made using a stainless steel die and ring as described by ANSI/ADA specification No. 19. 20 discs of each material were immersed in a 2.5% buffered glutaraldehyde solution for 30 minutes. Dimensional stability measurements were calculated immediately after fabrication and repeated on the same discs after 7 and 14 days of storage. The data was analyzed using two-way ANOVA with a significance level set at alpha = 0.05. RESULTS. The discs mean contraction was below 0.5% at all test times ranging from 0.200 + 0.014 to 0.325 + 0.007. Repeated measures ANOVA showed a statistically significant difference after 2-week storage between the disinfected and non-disinfected groups (P < .001). Although there was no statistically significant difference between the materials at the time of fabrication, the contraction of the materials increased with storage for 1 and 2 weeks. CONCLUSION. The dimensional changes of VPES impression discs after disinfection and prolonged storage complied with ANSI/ADA standard. The tested VPES impression materials were dimensionally stable for clinical use after disinfection for 30 minutes in glutaraldehyde and storage for up to 2 weeks.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 50 条
  • [41] Dimensional stability of elastomeric impression materials.
    Sermet, B
    Sen, D
    Bilgin, T
    Erturk, N
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1349 - 1349
  • [42] ACCURACY AND DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS
    EAMES, WB
    WALLACE, SW
    SUWAY, NB
    ROGERS, LB
    JOURNAL OF PROSTHETIC DENTISTRY, 1979, 42 (02): : 159 - 162
  • [43] Efficacy of Various Disinfecting Agents on the Reduction of Bacteria from the Surface of Silicone and Polyether Impression Materials
    Bal, Bilge Turhan
    Yilmaz, Handan
    Aydin, Cemal
    Dogruman, Al Funda
    Sultan, Nedim
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2007, 15 (04): : 177 - 182
  • [44] Comparison of accuracy/dimensional stability of high-rigid vinyl polysiloxane, polyvinyl siloxane, and polyether impression materials in full arch implant–supported prosthesis: In vitro study
    Kurella K.S.
    Thiyaneswaran N.
    Abhinav R.P.
    Journal of Long-Term Effects of Medical Implants, 2020, 30 (03): : 179 - 186
  • [45] 3-DIMENSIONAL INVESTIGATION OF THE ACCURACY OF IMPRESSION MATERIALS AFTER DISINFECTION
    KERN, M
    RATHMER, RM
    STRUB, JR
    JOURNAL OF PROSTHETIC DENTISTRY, 1993, 70 (05): : 449 - 456
  • [46] The effect of storage time on the accuracy and dimensional stability of reversible hydrocolloid impression material
    Schleier, PE
    Gardner, FM
    Nelson, SK
    Pashley, DH
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (03): : 244 - 250
  • [47] Accuracy and stability of impression materials subjected to chemical disinfection - a literature review
    Kotsiomiti, E.
    Tzialla, A.
    Hatjivasiliou, K.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (04) : 291 - 299
  • [48] Comparison of dimensional stability of elastomeric impression after immersion disinfection.
    Habib, C
    Smith, C
    Kugel, G
    Aboushala, A
    JOURNAL OF DENTAL RESEARCH, 1996, 75 : 357 - 357
  • [49] Effect of core materials on the dimensional accuracy of casts made of two different silicone impression materials: An experimental study
    Farzin, Mitra
    Derafshi, Reza
    Giti, Rashin
    Kalantari, Mohammad-Hassan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (02): : 196 - 204
  • [50] The dimensional stability of impression materials and its effect on in vitro tooth wear studies
    Rodriguez, Jose M.
    Bartlett, David W.
    DENTAL MATERIALS, 2011, 27 (03) : 253 - 258