3-DIMENSIONAL INVESTIGATION OF THE ACCURACY OF IMPRESSION MATERIALS AFTER DISINFECTION

被引:21
|
作者
KERN, M
RATHMER, RM
STRUB, JR
机构
[1] Albert-Ludwigs University, School of Dentistry, Freiburg
来源
JOURNAL OF PROSTHETIC DENTISTRY | 1993年 / 70卷 / 05期
关键词
D O I
10.1016/0022-3913(93)90084-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The influence of the two new disinfection systems Hygojet/MD 520 and Impresept on the accuracy of eight impression materials was evaluated with a clinically relevant abutment arrangement. In addition, an ''aseptic'' irreversible hydrocolloid was tested under the same test conditions but without the disinfection procedure. The dimensional changes of all eight impression materials related to the disinfection procedures were small. Although statistically significant interactions of the impression materials and the disinfection systems were found, the influence of the two tested disinfection systems on the dimensional accuracy of the impressions does not seem to be clinically relevant. From the standpoint of impression accuracy, both tested disinfection systems and the tested ''aseptic'' irreversible hydrocolloid can be recommended for clinical and laboratory use.
引用
收藏
页码:449 / 456
页数:8
相关论文
共 50 条
  • [1] USE OF A SCANNING LASER 3-DIMENSIONAL DIGITIZER TO EVALUATE DIMENSIONAL ACCURACY OF DENTAL IMPRESSION MATERIALS
    QUICK, DC
    HOLTAN, JR
    ROSS, GK
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (02): : 229 - 235
  • [2] Influence of impression material and time on the 3-dimensional accuracy of implant impressions
    Holst, Stefan
    Blatz, Markus B.
    Bergler, Michael
    Goellner, Matthias
    Wichmann, Manfred
    [J]. QUINTESSENCE INTERNATIONAL, 2007, 38 (01): : 67 - 73
  • [3] THE DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS FOLLOWING DISINFECTION
    LANGENWALTER, EM
    AQUILINO, SA
    TURNER, KA
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1990, 63 (03): : 270 - 276
  • [5] Disinfection procedures: their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts
    Taylor, RL
    Wright, PS
    Maryan, C
    [J]. DENTAL MATERIALS, 2002, 18 (02) : 103 - 110
  • [6] EFFECTS OF DISINFECTANTS ON DIMENSIONAL ACCURACY OF IMPRESSION MATERIALS
    MATYAS, J
    CAPUTO, AA
    LUCATORTO, FM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1990, 64 (01): : 25 - 31
  • [7] ACCURACY AND DIMENSIONAL STABILITY OF ELASTOMERIC IMPRESSION MATERIALS
    EAMES, WB
    WALLACE, SW
    SUWAY, NB
    ROGERS, LB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1979, 42 (02): : 159 - 162
  • [8] MARGIN FIT OF 9 IMPRESSION MATERIALS AFTER DISINFECTION
    CHRISTENSEN, WG
    CHRISTENSEN, RP
    JACOB, JS
    [J]. JOURNAL OF DENTAL RESEARCH, 1994, 73 : 397 - 397
  • [9] Accuracy and stability of impression materials subjected to chemical disinfection - a literature review
    Kotsiomiti, E.
    Tzialla, A.
    Hatjivasiliou, K.
    [J]. JOURNAL OF ORAL REHABILITATION, 2008, 35 (04) : 291 - 299
  • [10] THE DIMENSIONAL STABILITY OF POLYETHER, POLYSULFIDE AND SILICONE IMPRESSION MATERIALS AS WELL AS THE HARDNESS OF CASTS AFTER DISINFECTION
    PEROZ, I
    [J]. DEUTSCHE ZAHNARZTLICHE ZEITSCHRIFT, 1988, 43 (10): : 1066 - 1071