Attenuation estimation of long coaxial cable with regularization method

被引:0
|
作者
Gao, Yuan [1 ]
Wu, Shuang [1 ]
Qin, Feng [1 ]
机构
[1] CAEP, Inst Appl Elect, Mianyang, Sichuan, Peoples R China
关键词
Coaxial cable; attenuation estimation; regularization method; PARAMETER-ESTIMATION; ELECTROMAGNETICS; DECONVOLUTION;
D O I
10.1109/NEMO49486.2020.9343601
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The attenuation of the coaxial cable plays a key role in signal analysis, especially in precise measurement field. In general, the attenuation is measured by VNA. However, it needs to bend the cable to reduce the distance between the two ports when the length is long. This way easily breaks the actual work state, and the results may be quite different from the real. Other approaches, such as theoretical model calculation method, sweep frequency test method have obvious defects such as low precision and low efficiency. In this investigation, an inverse analysis approach of regularization method is developed. Preliminary verification has been carried out with simulation and experimental work; results show that the regularization method applied has good performance in estimating the attenuation of the coaxial cable. Moreover, as the biggest influence factor, the noise is also discussed in this work
引用
收藏
页数:3
相关论文
共 50 条
  • [31] COAXIAL CABLE AND APPARATUS
    DUVALL, GH
    RACKSON, LM
    BELL SYSTEM TECHNICAL JOURNAL, 1969, 48 (04): : 1065 - +
  • [32] Coaxial cable tester
    Fry, PW
    ELECTRONICS WORLD, 1996, 102 (1723): : 479 - 479
  • [33] A coaxial cable for the nanoworld
    不详
    CHEMICAL & ENGINEERING NEWS, 1998, 76 (33) : 37 - 37
  • [34] Coaxial cable choices
    Wheeler, N
    ELECTRONICS WORLD, 1996, (1720): : 244 - 246
  • [35] THE MANUFACTURE OF COAXIAL CABLE
    HAMMERSLA, WE
    JOURNAL OF METALS, 1950, 2 (05): : 755 - 756
  • [36] SWTV-ACE: Spatially Weighted Regularization Based Attenuation Coefficient Estimation Method for Hepatic Steatosis Detection
    Deeba, Farah
    Schneider, Caitlin
    Mohammed, Shahed
    Honarvar, Mohammad
    Tam, Edward
    Salcudean, Septimiu
    Rohling, Robert
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2019, PT V, 2019, 11768 : 610 - 618
  • [37] A METHOD OF EXTENDING THE RANGE OF OPTICAL CABLE ATTENUATION MEASUREMENTS
    YERMOLOV, AG
    OLEINIKOV, AD
    NAIDA, BD
    PERSHAKOV, VV
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1993, 48 (05) : 26 - 27
  • [38] An Analytical Method for Radiated Electromagnetic and Shielding Effectiveness of Braided Coaxial Cable
    Xiao, Pei
    Du, Ping-An
    Zhang, Bingxue
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2019, 61 (01) : 121 - 127
  • [39] Method for leaky coaxial cable fault diagnosis based on pulse compression
    Shi Y.-N.
    Liu J.-G.
    Liu Y.
    Guo J.-X.
    Wang Y.-Y.
    1600, China Coal Society (42): : 1078 - 1084
  • [40] Direct high frequency measurement method for small diameter coaxial cable
    Aoyagi, M
    Tanaka, S
    Kikuchi, K
    Unno, T
    Watanabe, K
    Matsuno, S
    Tokoro, K
    Nakagawa, H
    PROCEEDINGS OF 5TH ELECTRONICS PACKAGING TECHNOLOGY CONFERENCE, 2003, : 164 - 167