Attenuation estimation of long coaxial cable with regularization method

被引:0
|
作者
Gao, Yuan [1 ]
Wu, Shuang [1 ]
Qin, Feng [1 ]
机构
[1] CAEP, Inst Appl Elect, Mianyang, Sichuan, Peoples R China
关键词
Coaxial cable; attenuation estimation; regularization method; PARAMETER-ESTIMATION; ELECTROMAGNETICS; DECONVOLUTION;
D O I
10.1109/NEMO49486.2020.9343601
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The attenuation of the coaxial cable plays a key role in signal analysis, especially in precise measurement field. In general, the attenuation is measured by VNA. However, it needs to bend the cable to reduce the distance between the two ports when the length is long. This way easily breaks the actual work state, and the results may be quite different from the real. Other approaches, such as theoretical model calculation method, sweep frequency test method have obvious defects such as low precision and low efficiency. In this investigation, an inverse analysis approach of regularization method is developed. Preliminary verification has been carried out with simulation and experimental work; results show that the regularization method applied has good performance in estimating the attenuation of the coaxial cable. Moreover, as the biggest influence factor, the noise is also discussed in this work
引用
收藏
页数:3
相关论文
共 50 条
  • [21] THE METHOD OF REGULARIZATION AND BIASED-ESTIMATION
    CHISTYAKOV, VP
    THEORY OF PROBABILITY AND ITS APPLICATIONS, 1985, 29 (01) : 172 - 173
  • [22] Calculation of the capacitance of leaky coaxial cable by finite difference method
    Shi, Hua
    Shu, Lin
    Pei, Tao
    Wang, Jun-Hong
    Tiedao Xuebao/Journal of the China Railway Society, 2002, 24 (03):
  • [23] SUPERCONDUCTING COAXIAL CABLE
    GALPERIC.DY
    KHRENKOV, NN
    AKULICHE.VA
    BORODOVS.VS
    KUNEGIN, VS
    LAZUTKIN.LA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1971, 14 (01): : 328 - &
  • [24] COAXIAL CABLE TRANSMISSION
    SHIGEI, Y
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1965, 48 (01): : 114 - &
  • [25] LOCAL COAXIAL CABLE
    TAKIZAWA, J
    TOCHIGI, K
    JAPAN TELECOMMUNICATIONS REVIEW, 1974, 16 (03): : 218 - 222
  • [26] COAXIAL TELEPHONE CABLE TESTING USING A CW BURST METHOD
    BUTCHER, PM
    RADIO AND ELECTRONIC ENGINEER, 1981, 51 (01): : 21 - 30
  • [27] COAXIAL CABLE TESTING
    不详
    RADIO AND ELECTRONIC ENGINEER, 1979, 49 (05): : 224 - 224
  • [28] Analysis of slot-eavesdrop of coaxial cable with FDTD method
    Zhang, HX
    Lu, YH
    Huang, YM
    Yu, XP
    2002 3RD INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, 2002, : 264 - 267
  • [29] A new position detection method using leaky coaxial cable
    Nishikawa, Ken-ichi
    Higashino, Takeshi
    Tsukamoto, Katsutoshi
    Komaki, Shozo
    IEICE ELECTRONICS EXPRESS, 2008, 5 (08) : 285 - 290
  • [30] Coaxial cable development
    Fleuren, Jan
    Cable television engineering, 1988, 14 (03): : 544 - 546