Biomechanical evaluation of titanium, biodegradable plate and screw, and cyanoacrylate glue fixation systems in craniofacial surgery

被引:64
|
作者
Gosain, AK
Song, LS
Corrao, MA
Pintar, FA
机构
[1] Med Coll Wisconsin, Dept Plast & Reconstruct Surg, Milwaukee, WI 53226 USA
[2] Clement J Zablocki Vet Affairs Med Ctr, Dept Neurosurg, Milwaukee, WI USA
关键词
D O I
10.1097/00006534-199803000-00004
中图分类号
R61 [外科手术学];
学科分类号
摘要
Choice of appropriate fixation after reduction of displaced bone fragments or advancement of osteotomized segments requires knowledge of the maximal force to which these segments can be subjected. The present study,vas performed to obtain a biomechanical comparison of a variety of resorbable fixation systems as an alternative to metal plates and screws. Sheep cadaver parietal bone segments were osteotomized and fixed with one of six methods of fixation: (A) titanium plates and screws consisting of (1) miniplates and 2.0-mm-diameter screws; (2) midface plates and 1.5-mm screws; (3) microplates and 1.0-mm screws; (B) resorbable systems consisting of combinations of butyl-2-cyanoacrylate glue and biodegradable polylactic acid/polyglycolic acid copolymer plates and 2.0-mm screws as follows: (1) direct glue fixation of segments; (2) resorbable plates fixed to bone segments with cyanoacrylate glue; (3) resorbable plates fixed with resorbable screws. Compression testing was performed upon bone segments advanced and fixed across a central gap, and distraction testing was performed on bone segments fixed in direct contact. Force to failure in both distraction and compression was significantly greater in bone segments fixed with titanium miniplates than with any over method of fixation. Segments fixed with plates and screws, either nonresorbable or resorbable, achieved stronger fixation in distraction than in compression for all plate sizes tested. Resorbable plate and screw fixation was as strong as standard titanium midface and microplating systems in distraction, and stronger than the latter techniques in compression. With compressive forces of relapse, fixation with glue and resorbable plates was as strong as standard titanium midface and microplating systems. However, with distractive forces of relapse, glue fixation of either the bone segments or resorbable plates was weaker than both titanium and resorbable alternatives in which plates and screws were used. These findings may have direct impact on the choice of fixation devices used to support osteotomized or fractured bone segments, which are subjected to persistent muscular and soft-tissue pull.
引用
收藏
页码:582 / 591
页数:10
相关论文
共 50 条
  • [1] Craniofacial skeletal fixation using biodegradable plates and cyanoacrylate glue
    Ahn, DK
    Sims, CD
    Randolph, MA
    OConnor, D
    Butler, PEM
    Amarante, MTJ
    Yaremchuk, MJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (06) : 1508 - 1515
  • [3] Biomechanical Performance of Biodegradable Screw Fixation in Mandibular Distraction Osteogenesis
    Firriolo, Joseph Mark
    Xue, Yunfeng
    Weyerbacher, Jonathan S.
    Saldana, Golddy M.
    Garfinkel, Alec
    Garcia, Tanya C.
    Arzi, Boaz
    Wong, Granger B.
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (07) : 2228 - 2231
  • [4] Biomechanical Comparison of Odontoid Plate Fixation Versus Odontoid Screw Fixation
    Platzer, Patrick
    Eipeldauer, Stefan
    Leitgeb, Johannes
    Aldrian, Silke
    Vecsei, Vilmos
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (03): : 164 - 169
  • [5] FIXATION METHODS IN LATARJET: BIOMECHANICAL COMPARISON OF SCREW TYPES AND PLATE FIXATION
    Arzu, Ufuk
    Ersin, Mehmet
    Chodza, Mehmet
    Sahin, Koray
    Kilicoglu, Onder
    Ersen, Ali
    [J]. ACTA ORTOPEDICA BRASILEIRA, 2023, 31
  • [6] Resorbable plate fixation in pediatric craniofacial surgery
    Eppley, BL
    Sadove, AM
    Havlik, RJ
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 100 (01) : 1 - 7
  • [7] Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement
    Turvey, TA
    Bell, RB
    Phillips, C
    Proffit, WR
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (01) : 40 - 46
  • [8] Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures
    Misaghi, Amirhossein
    Doan, Josh
    Bastrom, Tracey
    Pennock, Andrew T.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (05): : 896 - 899
  • [9] A Randomized Clinical Trial of Biodegradable and Titanium Fixation Systems in Maxillofacial Surgery
    Buijs, G. J.
    van Bakelen, N. B.
    Jansma, J.
    de Visscher, J. G. A. M.
    Hoppenreijs, T. J. M.
    Bergsma, J. E.
    Stegenga, B.
    Bos, R. R. M.
    [J]. JOURNAL OF DENTAL RESEARCH, 2012, 91 (03) : 299 - 304
  • [10] Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery
    Bashti, Kaveh
    Tahmasebi, Mohammad N.
    Kaseb, Hasan
    Farahmand, Farzam
    Akbar, Mohammad
    Mobini, Amir
    [J]. ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2015, 3 (01): : 29 - 34