Biomechanical Performance of Biodegradable Screw Fixation in Mandibular Distraction Osteogenesis

被引:0
|
作者
Firriolo, Joseph Mark [1 ,4 ]
Xue, Yunfeng [1 ]
Weyerbacher, Jonathan S. [1 ]
Saldana, Golddy M. [1 ]
Garfinkel, Alec [2 ]
Garcia, Tanya C. [3 ]
Arzi, Boaz [3 ]
Wong, Granger B. [1 ]
机构
[1] Univ Calif Davis, Div Plast & Reconstruct Surg, Sacramento, CA USA
[2] Calif Northstate Univ, Coll Med, Elk Grove, CA USA
[3] Univ Calif Davis, Sch Vet Med, Dept Surg & Radiol Sci, Davis, CA USA
[4] Univ Calif Davis, Div Plast & Reconstruct Surg, 2335 Stockton Blvd,6th Floor, Sacramento, CA 95817 USA
关键词
Biomechanics; mandible; micrognathism; osteogenesis; distraction; BONE;
D O I
10.1097/SCS.0000000000009691
中图分类号
R61 [外科手术学];
学科分类号
摘要
Internal distraction devices are commonly used in congenital micrognathia. The eventual need for device and screw removal can be challenging, requiring extensive dissection and disturbance of bone regenerate. Bioabsorbable poly-L-lactide (PLLA) screws, compared to traditional titanium screws, simplify device removal. Previous in vivo studies have found that the maximal compressive force generated by mandibular distraction is 69.4N. We hypothesized that PLLA screws could support these compressive/distraction forces. Ten mandibles were obtained from 5 canine cadavers. Paired mandibles from the same cadaver were each fixated to a mandibular distractor with eight screws (either titanium or PLLA). Devices were each set to 15 and 30 mm of distraction distance. Compression force of 80 N was then generated parallel to the axis of the distraction device. Distractor displacement was measured to detect any mechanical failure during this pre-set load. Finally, if no failure was observed at 80 N, a load-to-failure compression test was done in the PLLA group to determine the mechanical failure point. All distractors in both the titanium and PLLA screw groups withstood 80 N of compression without failure. When the load-to-failure test was performed in the PLLA group, the average device failure point was 172.8 N (range 148-196 N). Review of high-frame-rate video demonstrated that all failures occurred due to the PLLA screws breaking or falling out. Bioabsorbable PLLA screws can withstand compressive forces more than double that of the maximal in vivo forces needed during mandibular distraction. These screws may be an acceptable alternative for the fixation of internal mandibular distractors.
引用
收藏
页码:2228 / 2231
页数:4
相关论文
共 50 条
  • [1] Biodegradable screw fixation in maxillofacial distraction osteogenesis
    Yamauchi, Kensuke
    Mitsugi, Masaharu
    Takahashi, Tehat
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2007, 65 (09) : 1859 - 1861
  • [2] Biomechanical properties of regenerated bone by mandibular distraction osteogenesis
    李继华
    胡静
    王大章
    唐正龙
    高占巍
    中华创伤杂志(英文版), 2002, (02) : 4 - 7
  • [3] Biomechanical properties of regenerated bone by mandibular distraction osteogenesis
    李继华
    胡静
    王大章
    唐正龙
    高占巍
    Chinese Journal of Traumatology, 2002, (02)
  • [4] Biomechanical Configurations of Mandibular Transport Distraction Osteogenesis Devices
    Zapata, Uriel
    Elsalanty, Mohammed E.
    Dechow, Paul C.
    Opperman, Lynne A.
    TISSUE ENGINEERING PART B-REVIEWS, 2010, 16 (03) : 273 - 283
  • [5] Biomechanical Assessment of Regenerate Integrity in Irradiated Mandibular Distraction Osteogenesis
    Schwarz, Daniel A.
    Jamali, Ameen M.
    Kakwan, Mehreen S.
    Fregene, Alero
    Arman, Krikor G.
    Buchman, Steven R.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2009, 123 (02) : 114S - 122S
  • [6] Mandibular Distraction Osteogenesis
    Sahoo, Nanda Kishore
    Issar, Yuvraj
    Thakral, Ankur
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : E743 - E746
  • [7] Biomechanical Analysis of the Effect of Mesenchymal Stem Cells on Mandibular Distraction Osteogenesis
    Aykan, Andac
    Ozturk, Serdar
    Sahin, Ismail
    Gurses, Senih
    Ural, Ali Ugur
    Oren, Nisa Cem
    Isik, Selcuk
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (02) : E169 - E175
  • [8] Histomorphologic, Biomechanical, and Functional Analysis in Mandibular Osteogenesis Induced by External Distraction
    Fuente-Del-Campo, Antonio
    Reyes Cureno, Daniel
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (03) : 1004 - 1008
  • [9] Self-reinforced biodegradable screw fixation compared with titanium screw fixation in mandibular advancement
    Turvey, TA
    Bell, RB
    Phillips, C
    Proffit, WR
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2006, 64 (01) : 40 - 46
  • [10] Biomechanical Effects of Screw Fixation in Second Mandibular Reconstruction Plate
    Chang, Ya-Wen
    Liu, Pao-Hsin
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 3167 - 3170