Determination of inorganic chlorine stable isotopes by continuous flow isotope ratio mass spectrometry

被引:52
|
作者
Shouakar-Stash, O [1 ]
Drimmie, RJ [1 ]
Frape, SK [1 ]
机构
[1] Univ Waterloo, Dept Earth Sci, Waterloo, ON N2L 3G1, Canada
关键词
D O I
10.1002/rcm.1762
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chlorine stable isotope analyses of inorganic samples were conducted using continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with gas chromatography (GC). Inorganic chloride was precipitated in the form of silver chloride (AgCl) by using silver nitrate in a standard methodology. Chlorine stable isotope analysis was carried out on methyl chloride (CH3Cl) after converting AgCl into CH3Cl by reacting it with methyl iodide (CH3I). The reaction between AgCl and CH3I took place in 20 mL size vials. Addition of CH3I was performed in a glove bag under helium flow. An Agilent 6890 gas chromatograph equipped with a CTC Analytics CombiPAL autosampler and a DB-5MS 60 m column was used to separate CH3Cl from CH3I. This new technique uses samples as small as 0.2 mg of AgCl (1.4 mumol of Cl-). The chlorine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure CH3Cl gas is better than +/-0.04parts per thousand (+/-STDV). The external precision using seawater standard is better than +/-0.07parts per thousand (+/-STDV) for n = 12. Moreover, the sample analysis time is much shorter and many more samples can be analyzed in one day than by using the conventional off-line techniques. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 50 条
  • [1] Determination of bromine stable isotopes using continuous-flow isotope ratio mass spectrometry
    Shouakar-Stash, O
    Frape, SK
    Drimmie, RJ
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4027 - 4033
  • [2] Stable chlorine isotope ratio analysis of subnanomolar level methyl chloride by continuous-flow isotope ratio mass spectrometry
    Konno, Uta
    Takai, Ken
    Kawagucci, Shinsuke
    [J]. GEOCHEMICAL JOURNAL, 2013, 47 (04) : 469 - 473
  • [3] Analysis of Compound-Specific Chlorine Stable Isotopes of Vinyl Chloride by Continuous Flow-Isotope Ratio Mass Spectrometry (FC-IRMS)
    Shouakar-Stash, Orfan
    Frape, S. K.
    Aravena, R.
    Gargini, A.
    Pasini, M.
    Drimmie, R. J.
    [J]. ENVIRONMENTAL FORENSICS, 2009, 10 (04) : 299 - 306
  • [4] Recent developments in the analysis of light isotopes by continuous flow isotope ratio mass spectrometry
    Midwood, AJ
    McGaw, BA
    [J]. ANALYTICAL COMMUNICATIONS, 1999, 36 (08): : 291 - 294
  • [5] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench Ⅱ
    刘运德
    周爱国
    甘义群
    刘存富
    余婷婷
    李小倩
    [J]. Journal of Central South University, 2013, 20 (01) : 193 - 198
  • [6] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench II
    Liu Yun-de
    Zhou Ai-guo
    Gan Yi-qun
    Liu Cun-fu
    Yu Ting-ting
    Li Xiao-qian
    [J]. JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2013, 20 (01) : 193 - 198
  • [7] An online method to determine chlorine stable isotope composition by continuous flow isotope ratio mass spectrometry (CF-IRMS) coupled with a Gasbench II
    Yun-de Liu
    Ai-guo Zhou
    Yi-qun Gan
    Cun-fu Liu
    Ting-ting Yu
    Xiao-qian Li
    [J]. Journal of Central South University, 2013, 20 : 193 - 198
  • [8] Membrane permeation continuous-flow isotope ratio mass spectrometry for on-line carbon isotope ratio determination
    Tremblay, Patrice
    Savard, Martine M.
    Smirnoff, Anna
    Paquin, Real
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (14) : 2213 - 2220
  • [9] Triple oxygen stable isotope analysis of nitrite measured using continuous flow isotope ratio mass spectrometry *
    Walters, Wendell W.
    Hastings, Meredith G.
    [J]. METHODSX, 2023, 11
  • [10] Evaluation of continuous flow - Isotope ratio mass spectrometry for quantitating stable isotope labeled compounds in biomedical tracer studies
    Browne, TR
    Szabo, GK
    Ajami, AM
    [J]. SYNTHESIS AND APPLICATIONS OF ISOTOPICALLY LABELLED COMPOUNDS 1997, 1998, : 321 - 324