Triple oxygen stable isotope analysis of nitrite measured using continuous flow isotope ratio mass spectrometry *

被引:0
|
作者
Walters, Wendell W. [1 ,2 ,3 ]
Hastings, Meredith G. [1 ,2 ]
机构
[1] Brown Univ, Inst Brown Environm & Soc, Providence, RI 02912 USA
[2] Brown Univ, Dept Earth Environm & Planetary Sci, Providence, RI 02912 USA
[3] Univ South Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
关键词
Isotope ratio mass spectrometry; Nitrate reduction; Nitrite; Chemical conversion; Mass-independence; Oxygen isotopes; CHEMICAL CONVERSION; ATMOSPHERIC NITRATE; NITROUS-OXIDE; NORTHEAST US; FRESH-WATER; FRACTIONATION; QUANTIFICATION; DELTA-N-15; DELTA-O-17; CHEMISTRY;
D O I
10.1016/j.mex.2023.102413
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Oxygen stable isotopes (i.e., 16 O, 17 O, 18 O) of nitrite (NO2 -) are useful for investigating chemical processes , sources contributing to this important environmental contaminant and nutrient. However, it remains difficult to quantify the oxygen isotope compositions of NO2 - due to the lack of internationally recognized NO2 - reference materials with a well-known Delta(17O) value. Here we have adopted a combination of methodologies to develop a technique for measuring Delta(17O) of NO2 - by reducing nitrate (NO3 -) materials with internationally recognized Delta(17O) values to NO2 - using activated cadmium catalyzed by chloride in a basic solution while conserving Delta(17O). The NO3 - reference materials reduced to NO2 - and sample NO2 - unknowns are converted to N2O using sodium azide/acetic acid reagent and decomposed to O 2 by passing through a heated gold tube and introduced into a continuous flow isotope ratio mass spectrometer for analysis at m/z 32, 33 , 34 for Delta(17O) quantification. The adapted method involves the following main points:center dot NO3 - reference materials with internationally recognized oxygen isotope composition are reduced to NO2 - under high pH conditions that conserve Delta(17O) values.center dot The NO3 - reference materials reduced to NO2 - and sample NO2 - with unknown Delta(17O) values are reduced to N2O using chemical methods involving sodium azide/acetic acid.center dot The product N2O is extracted, purified, decomposed to O 2 , analyzed for its isotope com-position using a continuous flow isotope ratio mass spectrometer for Delta(17O) quantification. The Delta(17O) of NO2 - samples are calibrated with respect to the NO3 - reference materials with known Delta(17O) values.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Oxygen isotope analysis of silicates using continuous flow isotope ratio mass spectrometry
    Kingston, A. W.
    Weis, D.
    Francois, R.
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2008, 72 (12) : A474 - A474
  • [2] An analytical system for stable isotope analysis on carbon monoxide using continuous-flow isotope-ratio mass spectrometry
    Pathirana, S. L.
    van der Veen, C.
    Popa, M. E.
    Roeckmann, T.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2015, 8 (12) : 5315 - 5324
  • [3] Stable chlorine isotope ratio analysis of subnanomolar level methyl chloride by continuous-flow isotope ratio mass spectrometry
    Konno, Uta
    Takai, Ken
    Kawagucci, Shinsuke
    GEOCHEMICAL JOURNAL, 2013, 47 (04) : 469 - 473
  • [4] Determination of bromine stable isotopes using continuous-flow isotope ratio mass spectrometry
    Shouakar-Stash, O
    Frape, SK
    Drimmie, RJ
    ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4027 - 4033
  • [5] Sample matrix effects on measured carbon and oxygen isotope ratios during continuous-flow isotope-ratio mass spectrometry
    Levitt, Nicholas Paul
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (21) : 2259 - 2274
  • [6] Determination of inorganic chlorine stable isotopes by continuous flow isotope ratio mass spectrometry
    Shouakar-Stash, O
    Drimmie, RJ
    Frape, SK
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (02) : 121 - 127
  • [7] Sulfur isotope analysis of sulfide and sulfate minerals by continuous flow-isotope ratio mass spectrometry
    Grassineau, NV
    Mattey, DP
    Lowry, D
    ANALYTICAL CHEMISTRY, 2001, 73 (02) : 220 - 225
  • [8] Evaluation of continuous flow - Isotope ratio mass spectrometry for quantitating stable isotope labeled compounds in biomedical tracer studies
    Browne, TR
    Szabo, GK
    Ajami, AM
    SYNTHESIS AND APPLICATIONS OF ISOTOPICALLY LABELLED COMPOUNDS 1997, 1998, : 321 - 324
  • [9] Stable isotope analysis of safety matches using isotope ratio mass spectrometry - a forensic case study
    Farmer, NL
    Meier-Augenstein, W
    Kalin, RM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (22) : 3182 - 3186
  • [10] Flow Injection Analysis-Isotope Ratio Mass Spectrometry for Bulk Carbon Stable Isotope Analysis of Alcoholic Beverages
    Jochmann, Maik A.
    Steinmann, Dirk
    Stephan, Manuel
    Schmidt, Torsten C.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (22) : 10489 - 10496