Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison

被引:8
|
作者
Skelton, E. [1 ,2 ]
Matthew, J. [1 ,2 ]
Li, Y. [3 ]
Khanal, B. [2 ]
Martinez, J. J. Cerrolaza [3 ]
Toussaint, N. [2 ]
Gupta, C. [1 ]
Knight, C. [1 ,4 ]
Kainz, B. [2 ,3 ]
Hajnal, J. V. [1 ,2 ]
Rutherford, M. [1 ,4 ]
机构
[1] Kings Coll London, Perinatal Imaging Dept, London, England
[2] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[3] Imperial Coll London, Dept Comp, London, England
[4] Guys & St Thomas NHS Fdn Trust, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Clinical evaluation; Fetal imaging; Quality assessment; Ultrasound; SONOGRAPHY; BRAIN; RELIABILITY; IMAGES; AUDIT;
D O I
10.1016/j.radi.2020.11.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Clinical evaluation of deep learning (DL) tools is essential to compliment technical accuracy metrics. This study assessed the image quality of standard fetal head planes automatically-extracted from three-dimensional (3D) ultrasound fetal head volumes using a customised DL-algorithm. Methods: Two observers retrospectively reviewed standard fetal head planes against pre-defined image quality criteria. Forty-eight images (29 transventricular, 19 transcerebellar) were selected from 91 transabdominal fetal scans (mean gestational age = 26 completed weeks, range = 20(+5)-32(+3) weeks). Each had two-dimensional (2D) manually-acquired (2D-MA), 3D operator-selected (3D-OS) and 3D-DL automatically-acquired (3D-DL) images. The proportion of adequate images from each plane and mo-dality, and the number of inadequate images per plane was compared for each method. Inter and intra-observer agreement of overall image quality was calculated. Results: Sixty-seven percent of 3D-OS and 3D-DL transventricular planes were adequate quality. Forty-five percent of 3D-OS and 55% of 3D-DL transcerebellar planes were adequate. Seventy-one percent of 3D-OS and 86% of 3D-DL transventricular planes failed with poor visualisation of intra-cranial structures. Eighty-six percent of 3D-OS and 80% of 3D-DL transcerebellar planes failed due to inadequate visualisation of cerebellar hemispheres. Image quality was significantly different between 2D and 3D, however, no significant difference between 3D-modalities was demonstrated (p < 0.005). Inter-observer agreement of transventricular plane adequacy was moderate for both 3D-modalities, and weak for transcerebellar planes. Conclusion: The 3D-DL algorithm can automatically extract standard fetal head planes from 3D-head volumes of comparable quality to operator-selected planes. Image quality in 3D is inferior to corre-sponding 2D planes, likely due to limitations with 3D-technology and acquisition technique. Implications for practice: Automated image extraction of standard planes from US-volumes could facil-itate use of 3DUS in clinical practice, however image quality is dependent on the volume acquisition technique. (c) 2020 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [31] Agreement of automated 3D ultrasound technique with manual 3D and 2D ultrasound for measurement of the transverse diameter of the levator ani hiatus
    Youssef, A.
    Brunelli, E.
    Del Magno, A.
    Fiorentini, M.
    Bernardi, V.
    Arosio, V.
    Pilu, G.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 62 : 105 - 105
  • [32] Automatic Fetal Face Detection From Ultrasound Volumes Via Learning 3D and 2D Information
    Feng, Shaolei
    Zhou, S. Kevin
    Good, Sara
    Comaniciu, Dorin
    CVPR: 2009 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-4, 2009, : 2480 - +
  • [33] Towards 3D face model from 2D view
    Skarbek, W
    Ignasiak, K
    Morgos, M
    Tomaszewski, M
    INTELLIGENT MEDIA TECHNOLOGY FOR COMMUNICATIVE INTELLIGENCE, 2005, 3490 : 158 - 162
  • [34] 2D vs. 3D ultrasound assessment for infertility evaluation on the 3rd day of the cycle
    Grigore, M.
    Mares, A.
    GIORNALE ITALIANO DI OSTETRICIA E GINECOLOGIA, 2012, 34 (01): : 189 - 191
  • [35] Prenatal assement of the fetal thymus: utility of 2D and 3D ultrasound in healthy fetuses
    Li, Ling
    Bahtiyar, Mert
    Zou, Lin
    Zhou, Qichang
    Copel, Joshua
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (06) : S137 - S138
  • [36] Clinical comparison of 2D transabdominal and 3D transperineal ultrasound image guidance methods for prostate RT
    Szegedi, M.
    Zhao, H.
    Rassiah, P.
    Sarkar, V.
    Huang, J.
    Huang, L.
    Tward, J.
    Kokeny, K.
    Salter, B. J.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S494 - S494
  • [37] Automatic detection of bidimensional fetal head planes from ultrasound 3D volumes using the 'Fetal Brain Plane Finding Prototype' tool
    Cavallaro, A.
    Donadono, V
    Salim, I
    Waechter-Stehle, I
    Klinder, T.
    J-M, Rouet
    Roundhill, D.
    Lorenz, C.
    Papageorghiou, A. T.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2017, 124 : 44 - 44
  • [38] 2D and 3D Image Quality Assessment: A Survey of Metrics and Challenges
    Niu, Yuzhen
    Zhong, Yini
    Guo, Wenzhong
    Shi, Yiqing
    Chen, Peikun
    IEEE ACCESS, 2019, 7 : 782 - 801
  • [39] Head to head comparison of 2D vs real time 3D dipyridamole stress echocardiography
    Varnero, Silvia
    Santagata, Patricia
    Pratali, Lorenza
    Basso, Massimiliano
    Gandolfo, Alfredo
    Bellotti, Paolo
    CARDIOVASCULAR ULTRASOUND, 2008, 6 (1)
  • [40] AutoMorph: Accelerating morphometrics with automated 2D and 3D image processing and shape extraction
    Hsiang, Allison Y.
    Nelson, Kaylea
    Elder, Leanne E.
    Sibert, Elizabeth C.
    Kahanamoku, Sara S.
    Burke, Janet E.
    Kelly, Abigail
    Liu, Yusu
    Hull, Pincelli M.
    METHODS IN ECOLOGY AND EVOLUTION, 2018, 9 (03): : 605 - 612