Towards automated extraction of 2D standard fetal head planes from 3D ultrasound acquisitions: A clinical evaluation and quality assessment comparison

被引:8
|
作者
Skelton, E. [1 ,2 ]
Matthew, J. [1 ,2 ]
Li, Y. [3 ]
Khanal, B. [2 ]
Martinez, J. J. Cerrolaza [3 ]
Toussaint, N. [2 ]
Gupta, C. [1 ]
Knight, C. [1 ,4 ]
Kainz, B. [2 ,3 ]
Hajnal, J. V. [1 ,2 ]
Rutherford, M. [1 ,4 ]
机构
[1] Kings Coll London, Perinatal Imaging Dept, London, England
[2] Kings Coll London, Sch Biomed Engn & Imaging Sci, London, England
[3] Imperial Coll London, Dept Comp, London, England
[4] Guys & St Thomas NHS Fdn Trust, London, England
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
Clinical evaluation; Fetal imaging; Quality assessment; Ultrasound; SONOGRAPHY; BRAIN; RELIABILITY; IMAGES; AUDIT;
D O I
10.1016/j.radi.2020.11.006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: Clinical evaluation of deep learning (DL) tools is essential to compliment technical accuracy metrics. This study assessed the image quality of standard fetal head planes automatically-extracted from three-dimensional (3D) ultrasound fetal head volumes using a customised DL-algorithm. Methods: Two observers retrospectively reviewed standard fetal head planes against pre-defined image quality criteria. Forty-eight images (29 transventricular, 19 transcerebellar) were selected from 91 transabdominal fetal scans (mean gestational age = 26 completed weeks, range = 20(+5)-32(+3) weeks). Each had two-dimensional (2D) manually-acquired (2D-MA), 3D operator-selected (3D-OS) and 3D-DL automatically-acquired (3D-DL) images. The proportion of adequate images from each plane and mo-dality, and the number of inadequate images per plane was compared for each method. Inter and intra-observer agreement of overall image quality was calculated. Results: Sixty-seven percent of 3D-OS and 3D-DL transventricular planes were adequate quality. Forty-five percent of 3D-OS and 55% of 3D-DL transcerebellar planes were adequate. Seventy-one percent of 3D-OS and 86% of 3D-DL transventricular planes failed with poor visualisation of intra-cranial structures. Eighty-six percent of 3D-OS and 80% of 3D-DL transcerebellar planes failed due to inadequate visualisation of cerebellar hemispheres. Image quality was significantly different between 2D and 3D, however, no significant difference between 3D-modalities was demonstrated (p < 0.005). Inter-observer agreement of transventricular plane adequacy was moderate for both 3D-modalities, and weak for transcerebellar planes. Conclusion: The 3D-DL algorithm can automatically extract standard fetal head planes from 3D-head volumes of comparable quality to operator-selected planes. Image quality in 3D is inferior to corre-sponding 2D planes, likely due to limitations with 3D-technology and acquisition technique. Implications for practice: Automated image extraction of standard planes from US-volumes could facil-itate use of 3DUS in clinical practice, however image quality is dependent on the volume acquisition technique. (c) 2020 The College of Radiographers. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [21] 2D and 3D Ultrasound Evaluation of Adenomyosis in Endometriosis: Pain Assessment before and after Surgery
    Pinzauti, Serena
    Lazzeri, Lucia
    Tosti, Claudia
    Centini, Gabriele
    Pino, Ida
    Petraglia, Felice
    Zupi, Errico
    REPRODUCTIVE SCIENCES, 2014, 21 (03) : 314A - 314A
  • [22] Comparison of 2D with 3D image alignment techniques for head and neck
    Sebastian, E. L.
    Kim, L. H.
    Wloch, J.
    Wu, Q.
    Yan, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S650 - S650
  • [23] Ultrasound propagation in 2D and 3D concrete models -: A quantitative comparison
    Schubert, F
    Köhler, B
    ANNUAL MEETING 1998 - NONDESTRUCTIVE MATERIALS TESTING: NONDESTRUCTIVE TESTING OF WELD JOINTS 70 YEARS LATER, 1997, 63 (1-2): : 549 - 560
  • [24] A 3D Freehand Ultrasound System for Multi-view Reconstructions from Sparse 2D Scanning Planes
    Honggang Yu
    Marios S Pattichis
    Carla Agurto
    M Beth Goens
    BioMedical Engineering OnLine, 10
  • [25] A 3D Freehand Ultrasound System for Multi-view Reconstructions from Sparse 2D Scanning Planes
    Yu, Honggang
    Pattichis, Marios S.
    Agurto, Carla
    Goens, M. Beth
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [26] No Reference 3D Mesh Quality Assessment Learned From Quality Scores on 2D Projections
    Ibork, Zaineb
    Nouri, Anass
    Lezoray, Olivier
    Charrier, Christophe
    Touahni, Raja
    IEEE ACCESS, 2024, 12 : 106924 - 106936
  • [27] 3D Kidney Reconstruction from 2D Ultrasound Images
    Teresa Alvarez-Gutierrez, Mariana
    Rodrigo Mejia-Rodriguez, Aldo
    Alejandro Cruz-Guerrero, Ines
    Roman Arce-Santana, Edgar
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 393 - 400
  • [28] The agreement between 3D, standard 2D and triplane 2D speckle tracking: Effects of image quality and 3D volume rate
    Trache T.
    Stöbe S.
    Tarr A.
    Pfeiffer D.
    Hagendorff A.
    Echo Research & Practice, 2014, 1 (2): : 71 - 83
  • [29] Automated subcortical volume estimation from 2D MRI in epilepsy, comparison with 3D MRI and implications for clinical trials
    Brownhilll, Daniel
    Chen, Ya-Chin
    Kreilkamp, Barbara
    Denby, Christine
    Bracewell, Martyn
    Biswas, Shubhabrata
    Das, Kumar
    Marson, Anthony
    Keller, Simon
    EPILEPSIA, 2021, 62 : 240 - 240
  • [30] Automated 3D ultrasound image analysis for first trimester assessment of fetal health
    Ryou, Hosuk
    Yaqub, Mohammad
    Cavallaro, Angelo
    Papageorghiou, Aris T.
    Noble, J. Alison
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (18):