来源
关键词
Patient setup errors; Cervical Cancer; DVH Analyzer;
D O I
10.1088/2057-1976/abf90a
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction. The present study aims to investigate the dosimetric and radiobiological impact of patient setup errors (PSE) on the target and organs at risk (OAR) of the cervix carcinoma stage IIB patients treated with volumetric-modulated arc therapy (VMAT) delivery technique using plan uncertainty parameters module of Varian Eclipse treatment planning system and in-house developed DVH Analyzer program. Materials and Methods. A total of 976 VMAT plans were generated to simulate the PSE in the base plan that varies from -10 mm to 10 mm in a step size of 1 mm in x- (lateral), y- (craniocaudal), and z- (anteroposterior) directions. The different OAR and tumor (PTV) volumes were delineated in each case. Various plan quality metrics, such as conformity index (CI) and homogeneity index (HI), as well as radiobiological quantities, such as tumor control probability (TCP) and normal tissue control probability (NTCP), were calculated from the DVH bands generated from the cohort of treatment plans associated with each patient case, using an in-house developed 'DVH Analyzer' program. The extracted parameters were statistically analyzed and compared with the base plan's dosimetric parameters having no PSE. Results. The maximum variation of (i) 2.4%, 21.5%, 0.8%, 2.5% in D-2cc of bladder, rectum, small bowel and sigmoid colon respectively; (ii) 19.3% and 18.9% in D-max of the left and right femoral heads (iii) 16.9% in D-95% of PTV (iv) 12.1% in NTCP of sigmoid colon were observed with change of PSE in all directions. TCP was found to be considerably affected for PSEs larger than 4 mm in x(+), y(+), z(+) directions and 7 mm in x(-), y(-) and z(-) directions, respectively. Conclusion. This study presents the effect of PSE on TCP and NTCP for the cervix carcinoma cases treated with VMAT technique and also recommends daily image guidance to mitigate the effects of PSE.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Dosimetric benefits of intensity-modulated radiotherapy and volumetric-modulated arc therapy in the treatment of postoperative cervical cancer patients
    Deng, Xia
    Han, Ce
    Chen, Shan
    Xie, Congying
    Yi, Jinling
    Zhou, Yongqiang
    Zheng, Xiaomin
    Deng, Zhenxiang
    Jin, Xiance
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (01): : 25 - 31
  • [2] A Treatment Planning Study Comparing Varian Volumetric Modulated Arc Therapy with IMRT using Oncentra Masterplan
    Chu, M.
    Millin, T.
    [J]. CLINICAL ONCOLOGY, 2011, 23 (03) : S20 - S21
  • [3] Dosimetric Effect of Plan Homogeneity On Intracranial Stereotactic Radiosurgery (SRS) Treatment Planning Using Volumetric Modulated Arc Therapy (VMAT)
    Tseng, T.
    Sheu, R.
    Green, S.
    Dharmarajan, K.
    Sharma, S.
    Lo, Y.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E334 - E334
  • [4] Dosimetric comparison of volumetric-modulated arc therapy and intensity-modulated radiation therapy in patients with cervical cancer: a meta-analysis
    Bai, Wei
    Kou, Changgui
    Yu, Weiying
    Li, Yuanyuan
    Hua, Wanqing
    Yu, Lei
    Wang, Jianfeng
    [J]. ONCOTARGETS AND THERAPY, 2018, 11 : 7179 - 7186
  • [5] Dosimetric Impact of Rotational Setup Errors for Cervical Cancer Patients With Postoperative Volumetric Modulated Arc Therapy
    Tsujii, K.
    Ueda, Y.
    Isono, M.
    Miyazaki, M.
    Teshima, T.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E603 - E603
  • [6] TREATMENT PLANNING COMPARISON OF FIXED FIELD INTENSITY MODULATED RADIOTHERAPY AND VOLUMETRIC ARC THERAPY IN PATIENTS WITH CERVICAL CANCER
    Banfill, K.
    Hunter, B.
    Smith, S.
    Harrand, R.
    Graham, K.
    Reed, N.
    Sadozye, A.
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2017, 27 : 700 - 700
  • [7] Volumetric Modulated Arc Therapy for Head and Neck Cancer: A Dosimetric and Treatment Planning Comparison with Intensity Modulated Radiotherapy Techniques
    Goswami, Brijesh
    Yadav, Suresh
    Jain, Rakesh Kumar
    Goswami, Pradeep
    [J]. JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (03)
  • [8] Improvement of treatment plan quality with modified fixed field volumetric modulated arc therapy in cervical cancer
    Jindakan, Sirawat
    Tharavichitkul, Ekkasit
    Watcharawipha, Anirut
    Nobnop, Wannapha
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024,
  • [9] A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy for postoperative treatment of cervical cancer
    Fuli Zhang
    Huayong Jiang
    Weidong Xu
    Yadi Wang
    Junmao Gao
    Qingzhi Liu
    Ping Wang
    Na Lu
    Diandian Chen
    Bo Yao
    Jun Hou
    Heliang He
    Jianping Chen
    [J]. Oncology and Translational Medicine, 2016, 2 (04) : 179 - 184
  • [10] Dosimetric Effect on Breast Cancer Patients Treated with Volumetric-Modulated Arc Therapy: Single Institutional Experience
    Hashem, Rania
    Mulla, Zaheeda
    Ghassal, Nour
    Bokhary, Ayman
    Howladar, Fatimah
    Fallatah, Kholoud
    Iskandarani, Omar
    Attar, Mohammad
    Ujaimi, Reem
    [J]. INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2021, 10 (02): : 55 - 62