Comparison of real-time PCR methods for detection of Salmonella enterica and Escherichia coli O157:H7, and introduction of a general internal amplification control

被引:58
|
作者
Klerks, MM
Zijlstra, C
van Bruggen, AHC
机构
[1] Univ Wageningen & Res Ctr, Plant Res Int BV, NL-6708 PB Wageningen, Netherlands
[2] Univ Wageningen & Res Ctr, Biol Farming Syst, NL-6709 PG Wageningen, Netherlands
关键词
green fluorescent; protein gene; internal amplification control; molecular beacon; pathogenic bacteria; real-time quantitative detection; statistical analysis; Taqman PCR;
D O I
10.1016/j.mimet.2004.07.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The objectives of this study were to compare different real-time PCR-based methods for detection of either Salmonella spp. or E. coli O157:H7 with respect to sensitivity, precision and accuracy. In addition, a general internal amplification control (IAC) is presented, allowing prevention of false negative results. The IAC allows insight in amplification efficiency and enables a more accurate quantification with the evaluated real-time PCR methods. Implementation of the IAC with the different PCR methods did not affect the precision of the methods, but the sensitivity was reduced 10-fold. Introduction of an IAC with the Salmonella enterica specific detection method showed a shift in Ct-value (increase of target Ct-value with 0.45 +/- 0.17 cycles), while with the method to detect E. coli O157:H7 no influence of IAC co-amplification was observed. The quantification threshold of the methods in which the IAC was included was determined at 1 pg of target DNA (equal to 200 CFU) per reaction. Qualitative detection was feasible down to 10 fg of target DNA per reaction using both methods in which the IAC was incorporated. The adjusted methods have the potential to provide fast and sensitive detection of Salmonella spp. or E coli O157:H7, enabling accurate quantification and preventing false negative results by using the general IAC. (C) 2004 Elsevier B.V All rights reserved.
引用
收藏
页码:337 / 349
页数:13
相关论文
共 50 条
  • [21] PCR for the Specific Detection of an Escherichia coli O157:H7 Laboratory Control Strain
    Knowles, Michael
    Lambert, Dominic
    Huszczynski, George
    Gauthier, Martine
    Blais, Burton W.
    JOURNAL OF FOOD PROTECTION, 2015, 78 (09) : 1738 - 1744
  • [22] Modification of methods for detection of Escherichia coli O157:H7 on produce
    Se-Ri Kim
    Yohan Yoon
    Min-Kyoung Seo
    Won-Il Kim
    Won-Bo Shim
    Duck Hwa Chung
    Jong Chul Yun
    Kyoung Yul Ryu
    Byung-Seok Kim
    Food Science and Biotechnology, 2014, 23 : 1349 - 1356
  • [23] The utility and application of real-time PCR and FISH in the detection of single-copy gene targets in Escherichia coli O157:H7 and Salmonella Typhimurium
    Haffar, Merriam
    Gilbride, Kimberley A.
    CANADIAN JOURNAL OF MICROBIOLOGY, 2010, 56 (03) : 254 - 262
  • [24] Modification of methods for detection of Escherichia coli O157:H7 on produce
    Kim, Se-Ri
    Yoon, Yohan
    Seo, Min-Kyoung
    Kim, Won-Il
    Shim, Won-Bo
    Chung, Duck Hwa
    Yun, Jong Chul
    Ryu, Kyoung Yul
    Kim, Byung-Seok
    FOOD SCIENCE AND BIOTECHNOLOGY, 2014, 23 (04) : 1349 - 1356
  • [25] A comprehensive review of detection methods for Escherichia coli O157:H7
    Bai, Zhuangzhuang
    Xu, Xianbao
    Wang, Cong
    Wang, Tan
    Sun, Chuanyu
    Liu, Shuangxi
    Li, Daoliang
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2022, 152
  • [26] QCM immunosensor with nanoparticle amplification for detection of Escherichia coli O157:H7
    Fei Liu
    Yanbin Li
    Xiao-Li Su
    Michael F. Slavik
    Yibin Ying
    Jianping Wang
    Sensing and Instrumentation for Food Quality and Safety, 2007, 1 (4): : 161 - 168
  • [27] Survival of Salmonella and Escherichia coli O157:H7 in chorizos
    Hew, CM
    Hajmeer, MN
    Farver, TB
    Glover, JM
    Cliver, DO
    JOURNAL OF FOOD PROTECTION, 2005, 68 (10) : 2039 - 2046
  • [28] Aptasensors for rapid detection of Escherichia coli O157:H7 and Salmonella typhimurium
    Wen-he Wu
    Min Li
    Yue Wang
    Hou-xian Ouyang
    Lin Wang
    Ci-xiu Li
    Yu-chen Cao
    Qing-he Meng
    Jian-xin Lu
    Nanoscale Research Letters, 7
  • [29] Real-time detection of Escherichia coli O157:H7 using a surface plasmon resonance biosensor
    Fratamico, PM
    Strobaugh, TP
    Medina, MB
    Gehring, AG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 17 - AGFD
  • [30] Aptasensors for rapid detection of Escherichia coli O157:H7 and Salmonella typhimurium
    Wu, Wen-he
    Li, Min
    Wang, Yue
    Ouyang, Hou-xian
    Wang, Lin
    Li, Ci-xiu
    Cao, Yu-chen
    Meng, Qing-he
    Lu, Jian-xin
    NANOSCALE RESEARCH LETTERS, 2012, 7