Accelerated dual-venc 4D flow MRI for neurovascular applications

被引:87
|
作者
Schnell, Susanne [1 ]
Ansari, Sameer A. [1 ,2 ]
Wu, Can [1 ,3 ]
Garcia, Julio [1 ,4 ]
Murphy, Ian G. [1 ]
Rahman, Ozair A. [1 ]
Rahsepar, Amir A. [1 ]
Aristova, Maria [1 ]
Collins, Jeremy D. [1 ]
Carr, James C. [1 ]
Markl, Michael [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Feinberg Sch Med, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Neurosurg, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[3] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, 737 N Michigan Ave,Ste 1600, Chicago, IL 60611 USA
[4] Univ Calgary, Cumming Sch Med, Stephenson Cardiac Imaging Ctr, Dept Cardiac Sci, Calgary, AB, Canada
关键词
4D flow MRI; dual venc; intracranial 4D flow MRI; PC-MRI; k-t GRAPPA; K-T-GRAPPA; COMPUTATIONAL FLUID-DYNAMICS; PHASE-CONTRAST MRI; WALL SHEAR-STRESS; 3D BLOOD-FLOW; IN-VIVO; VELOCITY; TIME; QUANTIFICATION; HEMODYNAMICS;
D O I
10.1002/jmri.25595
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo improve velocity-to-noise ratio (VNR) and dynamic velocity range of 4D flow magnetic resonance imaging (MRI) by using dual-velocity encoding (dual-venc) with k-t generalized autocalibrating partially parallel acquisition (GRAPPA) acceleration. Materials and MethodsA dual-venc 4D flow MRI sequence with k-t GRAPPA acceleration was developed using a shared reference scan followed by three-directional low- and high-venc scans (repetition time / echo time / flip angle=6.1 msec / 3.4 msec / 15 degrees, temporal/spatial resolution=43.0 msec/1.2 x 1.2 x 1.2mm(3)). The high-venc data were used to correct for aliasing in the low-venc data, resulting in a single dataset with the favorable VNR of the low-venc but without velocity aliasing. The sequence was validated with a 3T MRI scanner in phantom experiments and applied in 16 volunteers to investigate its feasibility for assessing intracranial hemodynamics (net flow and peak velocity) at the major intracranial vessels. In addition, image quality and image noise were assessed in the in vivo acquisitions. ResultsAll 4D flow MRI scans were acquired successfully with an acquisition time of 204 minutes. The shared reference scan reduced the total acquisition time by 12.5% compared to two separate scans. Phantom experiments showed 51.4% reduced noise for dual-venc compared to high-venc and an excellent agreement of velocities (=0.8, P < 0.001). The volunteer data showed decreased noise in dual-venc data (54.6% lower) compared to high-venc, and improved image quality, as graded by two observers: fewer artifacts (P < 0.0001), improved vessel conspicuity (P < 0.0001), and reduced noise (P < 0.0001). ConclusionDual-venc 4D flow MRI exhibits the superior VNR of the low-venc acquisition and reliably incorporates low- and high-velocity fields simultaneously. In vitro and in vivo data demonstrate improved flow visualization, image quality, and image noise. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:102-114
引用
收藏
页码:102 / 114
页数:13
相关论文
共 50 条
  • [21] Abdominal applications of quantitative 4D flow MRI
    Thekla H. Oechtering
    Grant S. Roberts
    Nikolaos Panagiotopoulos
    Oliver Wieben
    Alejandro Roldán-Alzate
    Scott B. Reeder
    Abdominal Radiology, 2022, 47 : 3229 - 3250
  • [22] Emerging Applications of Abdominal 4D Flow MRI
    Roldan-Alzate, Alejandro
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 58 - 66
  • [23] Test-retest multisite reproducibility of neurovascular 4D flow MRI
    Wen, Baohong
    Tian, Shuping
    Cheng, Jingliang
    Li, Yinhua
    Zhang, Huixia
    Xue, Kangkang
    Zhang, Zanxia
    Fan, Yang
    Wu, Bing
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (06) : 1543 - 1552
  • [24] A Dual-VENC Four-Dimensional Flow MRI Framework for Analysis of Subject-Specific Heterogeneous Nonlinear Vessel Deformation
    Concannon, J.
    Hynes, N.
    McMullen, M.
    Smyth, E.
    Moerman, K.
    McHugh, P. E.
    Sultan, S.
    Karmonik, C.
    McGarry, J. P.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (11):
  • [25] Accelerated aortic 4D flow MRI with wave-CAIPI
    Richter, Julian A. J.
    Wech, Tobias
    Weng, Andreas M.
    Stich, Manuel
    Jin, Ning
    Kosmala, Aleksander
    Bley, Thorsten A.
    Kostler, Herbert
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) : 2595 - 2607
  • [26] 4D Flow with MRI
    Soulat, Gilles
    McCarthy, Patrick
    Markl, Michael
    ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 22, 2020, 22 : 103 - 126
  • [27] 4D flow MRI
    Markl, Michael
    Frydrychowicz, Alex
    Kozerke, Sebastian
    Hope, Mike
    Wieben, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (05) : 1015 - 1036
  • [28] 4D flow MRI applications in congenital heart disease
    Rizk, Judy
    EUROPEAN RADIOLOGY, 2021, 31 (02) : 1160 - 1174
  • [29] 4D flow MRI applications in congenital heart disease
    Judy Rizk
    European Radiology, 2021, 31 : 1160 - 1174
  • [30] Intracardiac Flow at 4D CT: Comparison with 4D Flow MRI
    Lantz, Jonas
    Gupta, Vikas
    Henriksson, Lilian
    Karlsson, Matts
    Persson, Anders
    Carlhall, Carl-Johan
    Ebbers, Tino
    RADIOLOGY, 2018, 289 (01) : 51 - 58