Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4

被引:17
|
作者
Thiam, C. [1 ]
Bobin, C. [1 ]
Bouchard, J. [1 ]
机构
[1] CEA, LIST, LNE, LNHB, F-91191 Gif Sur Yvette, France
关键词
TDCR method; Liquid scintillation counting; GEANT4; simulation; Cherenkov effect; BIALKALI PHOTOCATHODES; CERENKOV RADIATION; COINCIDENCE SYSTEM;
D O I
10.1016/j.apradiso.2009.11.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The implementation of the TDCR method (Triple to Double Coincidence Ratio) is based on a liquid scintillation system which comprises three photomultipliers: at LNHB, this counter can also be used in the beta-channel of a 4 pi(beta)beta-gamma coincidence counting equipment It is generally considered that the gamma-sensitivity of the liquid scintillation detector comes from the interaction of the gamma-photons in the scintillation cocktail but when introducing solid gamma-ray emitting sources instead of the scintillation vial, light emitted by the surrounding of the counter is observed. The explanation proposed in this article is that this effect comes from the emission of Cherenkov photons induced by Compton diffusion in the photomultiplier windows In order to support this assertion, the creation and the propagation of Cherenkov photons inside the TDCR counter is simulated using the Monte Carlo code GEANT4. Stochastic calculations of double coincidences confirm the hypothesis of Cherenkov light produced in the photomultipher windows (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1515 / 1518
页数:4
相关论文
共 50 条
  • [41] Monte Carlo simulation based on Geant4 of single event upset induced by heavy ions
    Geng Chao
    Liu Jie
    Zhang ZhanGang
    Hou MingDong
    Sun YouMei
    Xi Kai
    Gu Song
    Duan JingLai
    Yao HuiJun
    Mo Dan
    Luo Jie
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2013, 56 (06) : 1120 - 1125
  • [42] Monte Carlo simulation based on Geant4 of single event upset induced by heavy ions
    GENG Chao
    LIU Jie
    ZHANG ZhanGang
    HOU MingDong
    SUN YouMei
    XI Kai
    GU Song
    DUAN JingLai
    YAO HuiJun
    MO Dan
    LUO Jie
    Science China(Physics,Mechanics & Astronomy), 2013, (06) : 1120 - 1125
  • [43] Monte Carlo simulation of Novalis Classic 6 MV accelerator using phase space generation in GATE/Geant4 code
    Teixeira, M. S.
    Batista, D. V. S.
    Braz, D.
    da Rosa, L. A. R.
    PROGRESS IN NUCLEAR ENERGY, 2019, 110 : 142 - 147
  • [44] Monte Carlo Simulation of an Ir-192 Brachytherapy Source Spectra, Geometry and Anysotropy Factors Using Geant4 Code
    Fonseca-Rodrigues, S. S. O.
    Begalli, M.
    Queiroz Filho, P. P.
    Souza-Santos, D.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 544 - +
  • [45] MONTE CARLO SIMULATION OF AN Ir-192 BRACHYTHERAPY SOURCE SPECTRA, GEOMETRY AND ANYSOTROPY FACTORS USING GEANT4 CODE
    Oliveira Fonseca Rodrigues, Sane Simone
    Begalli, Marcia
    de Queiroz Filho, Pedro Pacheco
    Santos, Denison de Souza
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 132 - +
  • [46] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [47] Verification and Validation of the Geant4 Monte Carlo Code Toolkit for DEMO TBR Evaluations
    Nunnenmann, Elena
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2020, 161
  • [48] Monte Carlo simulation of the CENBG microbeam and nanobeam lines with the Geant4 toolkit
    Incerti, S.
    Zhang, Q.
    Andersson, F.
    Moretto, Ph.
    Grime, G. W.
    Merchant, M. J.
    Nguyen, D. T.
    Habchi, C.
    Pouthier, T.
    Seznec, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 260 (01): : 20 - 27
  • [49] GePEToS: A Geant4 Monte Carlo simulation package for positron emission tomography
    Jan, S
    Collot, J
    Gallin-Martel, ML
    Martin, P
    Mayet, F
    Tournefier, E
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) : 102 - 106
  • [50] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489