Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4

被引:17
|
作者
Thiam, C. [1 ]
Bobin, C. [1 ]
Bouchard, J. [1 ]
机构
[1] CEA, LIST, LNE, LNHB, F-91191 Gif Sur Yvette, France
关键词
TDCR method; Liquid scintillation counting; GEANT4; simulation; Cherenkov effect; BIALKALI PHOTOCATHODES; CERENKOV RADIATION; COINCIDENCE SYSTEM;
D O I
10.1016/j.apradiso.2009.11.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The implementation of the TDCR method (Triple to Double Coincidence Ratio) is based on a liquid scintillation system which comprises three photomultipliers: at LNHB, this counter can also be used in the beta-channel of a 4 pi(beta)beta-gamma coincidence counting equipment It is generally considered that the gamma-sensitivity of the liquid scintillation detector comes from the interaction of the gamma-photons in the scintillation cocktail but when introducing solid gamma-ray emitting sources instead of the scintillation vial, light emitted by the surrounding of the counter is observed. The explanation proposed in this article is that this effect comes from the emission of Cherenkov photons induced by Compton diffusion in the photomultiplier windows In order to support this assertion, the creation and the propagation of Cherenkov photons inside the TDCR counter is simulated using the Monte Carlo code GEANT4. Stochastic calculations of double coincidences confirm the hypothesis of Cherenkov light produced in the photomultipher windows (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1515 / 1518
页数:4
相关论文
共 50 条
  • [21] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [22] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, (11) : 1150 - 1156
  • [23] The Design of a Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder Using GEANT4 Monte Carlo Simulation Code
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E857 - E858
  • [24] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [26] Generation of primary photons through inverse Compton scattering using a Monte Carlo simulation code
    Paterno, Gianfranco
    Cardarelli, Paolo
    Bianchini, Matteo
    Taibi, Angelo
    Drebot, Illya
    Petrillo, Vittoria
    Hajima, Ryoichi
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2022, 25 (08)
  • [27] Monte carlo simulation of the response to fast neutrons of a multi-gap RPC (MRPC) by using the GEANT4 code
    J. T. Rhee
    Hyun Yong Jo
    M. Jamil
    Y. J. Jeon
    Journal of the Korean Physical Society, 2012, 60 : 1023 - 1027
  • [28] Monte Carlo Simulation of a Special Phantom with Geant4 Application for Tomography
    Bardane, Adil
    Tajmouaati, Jaouad
    Maghnouj, Abdelmajid
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 58 - 62
  • [29] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [30] TOUCANS: A versatile Monte Carlo neutron transport code based on GEANT4
    Thulliez, L.
    Mom, B.
    Dumonteil, E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1051