Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4

被引:17
|
作者
Thiam, C. [1 ]
Bobin, C. [1 ]
Bouchard, J. [1 ]
机构
[1] CEA, LIST, LNE, LNHB, F-91191 Gif Sur Yvette, France
关键词
TDCR method; Liquid scintillation counting; GEANT4; simulation; Cherenkov effect; BIALKALI PHOTOCATHODES; CERENKOV RADIATION; COINCIDENCE SYSTEM;
D O I
10.1016/j.apradiso.2009.11.066
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The implementation of the TDCR method (Triple to Double Coincidence Ratio) is based on a liquid scintillation system which comprises three photomultipliers: at LNHB, this counter can also be used in the beta-channel of a 4 pi(beta)beta-gamma coincidence counting equipment It is generally considered that the gamma-sensitivity of the liquid scintillation detector comes from the interaction of the gamma-photons in the scintillation cocktail but when introducing solid gamma-ray emitting sources instead of the scintillation vial, light emitted by the surrounding of the counter is observed. The explanation proposed in this article is that this effect comes from the emission of Cherenkov photons induced by Compton diffusion in the photomultiplier windows In order to support this assertion, the creation and the propagation of Cherenkov photons inside the TDCR counter is simulated using the Monte Carlo code GEANT4. Stochastic calculations of double coincidences confirm the hypothesis of Cherenkov light produced in the photomultipher windows (C) 2009 Elsevier Ltd. All rights reserved
引用
收藏
页码:1515 / 1518
页数:4
相关论文
共 50 条
  • [1] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [2] SIMULATION OF THE NEUTRON SPECTRA EVOLUTION WITH GEANT4 MONTE CARLO CODE
    Smolyar, V. P.
    Mileva, A. O.
    Tarasov, V. O.
    Neboha, H. H.
    Rusov, V. D.
    JOURNAL OF PHYSICAL STUDIES, 2021, 25 (02):
  • [3] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [4] Monte Carlo simulation of the ELIMED beamline using Geant4
    Pipek, J.
    Romano, F.
    Milluzzo, G.
    Cirrone, G. A. P.
    Cuttone, G.
    Amico, A. G.
    Margarone, D.
    Larosa, G.
    Leanza, R.
    Petringa, G.
    Schillaci, F.
    Scuderi, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [5] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [6] Optimization of the Monte Carlo simulation model of NaI(Tl) detector by Geant4 code
    Hoang Duc Tam
    Nguyen Thi Hai Yen
    Le Bao Tran
    Huynh Dinh Chuong
    Tran Thien Thanh
    APPLIED RADIATION AND ISOTOPES, 2017, 130 : 75 - 79
  • [7] Monte Carlo simulation of NovalisTx linear accelerator using GATE/Geant4 code for dosimetry analysis
    Fathi, Ahmed
    Khobbaizi, Youness
    Nabil, Sanaa
    Ardouz, Anas
    Hasnaoui, Abdellatif
    Sbiaai, Khalid
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 466 - 472
  • [8] Erratum to: Simulation of Electron Trajectories in the Multicusp Ion Source Using Geant4 Monte Carlo Code
    Fatemeh Khodadadi Azadboni
    Mahmood Sedaghatizade
    Journal of Fusion Energy, 2010, 29 : 305 - 305
  • [9] Monte Carlo study of a double-scattering Compton camera with GEANT4
    Seo, Hee
    An, So Hyun
    Kim, Jong Kyung
    Kim, Chan Hyeong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 314 - 317
  • [10] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662