Energy filtering with X-ray lenses: optimization for photon-counting mammography

被引:0
|
作者
Fredenberg, Erik [1 ]
Cederstrom, Bjorn [1 ]
Danielsson, Mats [1 ]
机构
[1] Royal Inst Technol, Dept Phys, SE-10691 Stockholm, Sweden
基金
瑞典研究理事会;
关键词
D O I
10.1093/rpd/ncq049
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Chromatic properties of the multi-prism and prism-array X-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The line-shaped foci of the lenses are optimal for coupling to photon-counting silicon strip detectors in a scanning system. A theoretical model was developed and used to investigate the benefit of two lenses compared with an absorption-filtered reference system. The dose reduction of the MPL filter was similar to 15% compared with the reference system at matching scan time, and the spatial resolution was higher. The dose of the PAL-filtered system was found to be similar to 20% lower than for the reference system at equal scan time and resolution, and only similar to 20% higher than for a monochromatic beam. An investigation of some practical issues remains, including the feasibility of brilliant-enough X-ray sources and manufacturing of a polymer PAL.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 50 条
  • [41] Indirect photon-counting x-ray imaging using CMOS Photon Detector (CPD)
    Nishihara, Toshiyuki
    Baba, Hiroyasu
    Matsumura, Masao
    Kumagai, Oichi
    Izawa, Takashi
    MEDICAL IMAGING 2019: PHYSICS OF MEDICAL IMAGING, 2019, 10948
  • [42] Monte-Carlo Simulation of the Detective Quantum Efficiency of Cadmium Telluride X-Ray Detectors for Photon-Counting Mammography
    Day, J.
    Tanguay, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [43] An Approach to System Optimization for X-Ray Photon-Counting Systems Using Performance on a Detection/Localization Task
    Lu, Yihuan
    Zhang, Hao
    Liang, Zhengrong
    Gindi, Gene
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [44] Photon-counting imaging camera for high-resolution X-ray and γ-ray applications
    Hall, D. J.
    Holland, A.
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [45] Energy-sensitive scatter estimation and correction for spectral x-ray imaging with photon-counting detectors
    Lewis, Cale E.
    Das, Mini
    JOURNAL OF INSTRUMENTATION, 2022, 17 (12)
  • [46] Spectral X-Ray CT Image Reconstruction with a Combination of Energy-Integrating and Photon-Counting Detectors
    Yang, Qingsong
    Cong, Wenxiang
    Xi, Yan
    Wang, Ge
    PLOS ONE, 2016, 11 (05):
  • [47] Anti-correlated noise reduction in triple-energy, photon-counting x-ray angiography
    Tanguay, Jesse
    Sims, Kaitlyn
    Aubert, Sarah
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [48] Photon-counting energy-resolving CdTe detectors for high-flux x-ray imaging
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Hartsough, Neal E.
    Gandhi, Thulasi
    Wawrzyniak, Gregor
    Iwanczyk, Jan S.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3953 - 3955
  • [49] Performance of an improved readout IC for multi-energy photon-counting x-ray detector arrays
    Clajus, Martin
    Cajipe, Victoria B.
    Hayakawa, Satoshi
    Tuemer, Tuemay O.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS X, 2008, 7079
  • [50] Mcps-range photon-counting X-ray computed tomography system
    Sato, Eiichi
    Oda, Yasuyuki
    Abudurexiti, Abulajiang
    Hagiwara, Osahiko
    Enomoto, Toshiyuki
    Sugimura, Shigeaki
    Endo, Haruyuki
    Sato, Shigehiro
    Ogawa, Akira
    Onagawa, Jun
    MEDICAL APPLICATIONS OF RADIATION DETECTORS, 2011, 8143