Chromatic properties of the multi-prism and prism-array X-ray lenses (MPL and PAL) can potentially be utilized for efficient energy filtering and dose reduction in mammography. The line-shaped foci of the lenses are optimal for coupling to photon-counting silicon strip detectors in a scanning system. A theoretical model was developed and used to investigate the benefit of two lenses compared with an absorption-filtered reference system. The dose reduction of the MPL filter was similar to 15% compared with the reference system at matching scan time, and the spatial resolution was higher. The dose of the PAL-filtered system was found to be similar to 20% lower than for the reference system at equal scan time and resolution, and only similar to 20% higher than for a monochromatic beam. An investigation of some practical issues remains, including the feasibility of brilliant-enough X-ray sources and manufacturing of a polymer PAL.
引用
收藏
页码:339 / 342
页数:4
相关论文
共 50 条
  • [31] Novel Photon-Counting Energy-Resolving Ultra-Fast X-Ray Detector
    Ertosun, M. Guenhan
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [32] Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study
    Cho, H-M
    Ding, H.
    Ziemer, B. P.
    Molloi, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7211 - 7227
  • [33] Spectral Signatures of X-ray Scatter Using Energy-Resolving Photon-Counting Detectors
    Lewis, Cale E.
    Das, Mini
    SENSORS, 2019, 19 (22)
  • [34] Digital signal processing for CdTe photon-counting X-ray sensor
    Shinomiya, B.
    Koike, A.
    Morii, H.
    Neo, Y.
    Mimura, H.
    Aoki, T.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4980 - +
  • [35] Optimization of energy windows to calculate quantitative X-ray images using an energy-resolving photon-counting detector: A simulation study
    Nishigami, Rina
    Kobayashi, Daiki
    Kimoto, Natsumi
    Asahara, Takashi
    Maeda, Tatsuya
    Haba, Tomonobu
    Kanazawa, Yuki
    Yamamoto, Shuichiro
    Hayashi, Hiroaki
    Radiation Physics and Chemistry, 2025, 229
  • [36] Characterization of spectrometric photon-counting X-ray detectors at different pitches
    Jurdit, M.
    Brambilla, A.
    Moulin, V.
    Ouvrier-Buffet, P.
    Radisson, P.
    Verger, L.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [37] NOISE DUE TO PHOTON-COUNTING STATISTICS IN COMPUTED X-RAY TOMOGRAPHY
    CHESLER, DA
    RIEDERER, SJ
    PELC, NJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1977, 1 (01) : 64 - 74
  • [38] Spectral computed tomography in the age of photon-counting X-ray detectors
    Rotkopf, Lukas T.
    Wehrse, Eckhard
    Froelich, Matthias F.
    RADIOLOGIE, 2022, 62 (06): : 504 - 510
  • [39] PHOTON-COUNTING SPECTROMETER FOR ATTENUATION MEASUREMENTS IN SOFT X-RAY REGION
    BEDO, DE
    TOMBOULIAN, DH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1961, 32 (02): : 184 - &
  • [40] Guidelines for the Selection of Scintillators for Indirect Photon-Counting X-ray Detectors
    van Blaaderen, J. Jasper
    van Aarle, Casper
    Leibold, David
    Dorenbos, Pieter
    Schaart, Dennis R.
    Chemistry of Materials, 2025, 37 (05) : 1716 - 1740