Reducing intra-fraction organ motion effects using segment size constraint in direct aperture optimization

被引:0
|
作者
Zhang, G. [1 ]
Yi, B. [1 ]
Jiang, Z. [1 ]
Yu, C. [1 ]
机构
[1] Univ Maryland, Med Ctr, Baltimore, MD 21201 USA
关键词
D O I
10.1118/1.2761248
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In IMRT delivery, an important issue is intra‐fraction organ motion, which causes significant degradation of the delivered dose. Some simulation researches have showed that organ motion effects could be significantly reduced by increasing the segment size. In this study, a direct aperture optimization based commercial inverse planning system was modified to assess the clinical impact of creating optimized plans with segment size constraints (SSC). Our study seeks to answer what price in static plan quality one has to pay to avoid dose degradation in moving targets? Method and Materials: IMRT plans with and without SSC were optimized for two abdominal cases using static CT images. The MLC travel direction is aligned with the projected motion direction and SSC penalizes all MLC leaf openings smaller than twice the projected motion amplitude. Static plans were recalculated with a sinusoidal target motion with 1cm amplitude and 4second period. Results: In both cases with and without SSC, PTV volume covered by 95% of the prescribed dose (V95) was less than 1%, indicating that SSC had little effect on static plan quality. After incorporating target motion, V95 was improved by applying SSC, with the degree of improvement depending on the particular case. For case 1, V95 improved from 84.5% to 93.3% by adding SSC. Further study shows that dose coverage of peripheral PTV regions improved more significantly with SSC than central regions. In all plans, differences of the doses to the critical structures were within a few percent. By adding SSC, the treatment plan was more tolerant to target motion. Conclusions: Our study showed that when segmental IMRT plans were delivered to a moving target, SSC improves delivered dose conformity (V95) as much as 9% without significantly sacrificing static plan quality. Peripheral PTV shows more improvement in dose coverage with SSC than central regions. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2524 / 2524
页数:1
相关论文
共 50 条
  • [21] Effects of intra-fraction motion on IMRT treatments with low monitor unit segments
    Seco, J.
    Gierga, D.
    Sharp, G.
    Turcotte, J.
    Paganetti, H.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1763 - +
  • [22] Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI
    van Heijst, T.
    Philippens, M.
    van den Bongard, D.
    van Asselen, B.
    Lagendijk, J.
    Kleijnen, J.
    den Hartogh, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 100 - 100
  • [23] Quantification of intra-fraction motion in breast radiotherapy using cine EPID images
    Fouladinezhad, Behnaz
    Momennezhad, Mehdi
    Farjami, Parisa
    Naseri, Shahrokh
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [24] Accurate prediction of intra-fraction motion using a modified linear adaptive filter
    Srivastava, V.
    Keall, P.
    Sawant, A.
    Suh, Y.
    MEDICAL PHYSICS, 2007, 34 (06) : 2546 - 2546
  • [25] Intra-fraction organ motion in breast radiotherapy: a comparison of prone versus supine patient positioning.
    DeWyngaert, J. K.
    Mitchell, J. D.
    Formenti, S. C.
    BREAST CANCER RESEARCH AND TREATMENT, 2006, 100 : S201 - S202
  • [26] Management of intra-fraction organ motion: first performance evaluation of an experimental dynamic tumor tracking system
    Oelfke, U.
    Tacke, M.
    Kraus, A.
    Nill, S.
    MEDICAL PHYSICS, 2009, 36 (09) : 4302 - 4302
  • [27] Performance optimization of capacitive motion sensing (CMS) system for intra-fraction motion detection during stereotactic radiosurgery
    Semeniuk O.
    Sadeghi P.
    Farah J.D.
    Moran K.
    Robar J.
    Biomedical Physics and Engineering Express, 2020, 6 (01):
  • [28] Inter-fraction and intra-fraction breast motion localized using AlignRT for early breast cancer
    Miller, D. A.
    Klein, E. E.
    Zoberi, I.
    Taylor, M. E.
    Powell, S. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S189 - S190
  • [29] A cohort study using milk of magnesia for the reduction of intra-fraction prostate motion.
    Nichol, A
    Jaffray, D
    Catton, C
    Milosevic, M
    Bayley, A
    McLean, M
    Bristow, R
    Crook, J
    Gospodarowicz, M
    Haycocks, T
    Kirilova, A
    Lockwood, G
    Warde, P
    RADIOTHERAPY AND ONCOLOGY, 2004, 72 : S53 - S53
  • [30] Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging
    van Heijst, Tristan C. F.
    Philippens, Marielle E. P.
    Charaghvandi, Ramona K.
    den Hartogh, Mariska D.
    Lagendijk, Jan J. W.
    van den Bongard, H. J. G. Desiree
    van Asselen, Bram
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1352 - 1370