Quantification of intra-fraction motion in breast radiotherapy using cine EPID images

被引:0
|
作者
Fouladinezhad, Behnaz [1 ]
Momennezhad, Mehdi [1 ,2 ]
Farjami, Parisa [3 ]
Naseri, Shahrokh [1 ]
机构
[1] Mashhad Univ Med Sci, Med Phys Res Ctr, Mashhad, Iran
[2] Mashhad Univ Med Sci, Nucl Med Res Ctr, Mashhad, Iran
[3] Islamic Azad Univ, Dept Biol, Mashhad, Iran
关键词
Automated motion estimation algorithm; breast cancer; conformal radiation therapy; EPID; IRRADIATION; FREQUENCY; ALGORITHM;
D O I
10.1017/S1460396924000049
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study was to develop a method for accurately measuring the intra-fraction motion in cine electronic portal imaging device (EPID) images of tangential breast irradiation. Patients and methods: The cine EPID images were acquired for 18 breast cancer patients during medial tangential breast radiotherapy. The skin surface and the chest wall were segmented separately in each EPID image using an automated MATLAB algorithm to obtain the magnitude of intra-fraction motion. Results: The patients had an average age of 55 years (range 43-69 years), with the highest observed displacement at 3<middle dot>50 mm. The mean intra-fraction motion due to respiration for the skin surface and chest wall was 1<middle dot>04 +/- 0<middle dot>24 mm and 1<middle dot>10 +/- 0<middle dot>27 mm, respectively. The amount of intra-fraction motion showed no significant association with either the patient's age or the side of the breast receiving the treatment. Conclusion: In this study, by utilising cine EPID technology and the automated MATLAB algorithm, the intra-fraction motion during breast radiotherapy treatment was accurately measured and analysed. Results indicate minimal skin surface and chest wall motion (approximately 1 mm), confirming negligible intra-fraction motions during conformal radiotherapy in breast cancer patients.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] BREATHING MOTION IN SUPINE AND PRONE BREAST CANCER RADIOTHERAPY: INTRA-FRACTION DISPLACEMENTS USING AN EPID IN CINE MODE ACQUISITION
    Gaudino, D.
    Ramella, S.
    Stimato, G.
    Cellini, F.
    Ciresa, M.
    Fiore, M.
    Greco, C.
    Altomare, V.
    Carino, R.
    Primavera, A.
    Stagnitto, D.
    Andrich, R.
    D'Angelillo, R. M.
    Trodella, L.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S194 - S195
  • [2] Quantification of Intra-Fraction Motion of Breast Tumors Using Cine-MRI
    van Heijst, T.
    Philippens, M.
    van den Bongard, D.
    van Asselen, B.
    Lagendijk, J.
    Kleijnen, J.
    den Hartogh, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 100 - 100
  • [3] Determining intra-fraction motion in breast radiotherapy using supine cine-MRI
    Van Heijst, T. C. F.
    Philippens, M. E. P.
    Den Hartogh, M. D.
    Lagendijk, J. J. W.
    Van den Bongard, H. J. G. D.
    Van Asselen, B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S479 - S480
  • [4] Quantification of intra-fraction motion in breast radiotherapy using supine magnetic resonance imaging
    van Heijst, Tristan C. F.
    Philippens, Marielle E. P.
    Charaghvandi, Ramona K.
    den Hartogh, Mariska D.
    Lagendijk, Jan J. W.
    van den Bongard, H. J. G. Desiree
    van Asselen, Bram
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (03): : 1352 - 1370
  • [5] Intra-Fraction Motion of Larynx Radiotherapy
    Durmus, Ismail Faruk
    Tas, Bora
    TURKISH PHYSICAL SOCIETY 33RD INTERNATIONAL PHYSICS CONGRESS (TPS33), 2018, 1935
  • [6] Lung tumor intra-fraction motion during Stereotactic Body RadioTherapy (SBRT): An evaluation using cine MR
    Saito, A. I.
    Li, J. G.
    Liu, C.
    Olivier, K. R.
    Dempsey, J. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S505 - S505
  • [7] Surface Imaging Based Analysis of Intra-Fraction Motion for Breast Radiotherapy Patients
    Wiant, D.
    Wentworth, S.
    Maurer, J.
    Vanderstraeten, C.
    Terrell, J.
    Sintay, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 97 - 97
  • [8] Marker-less intra-fraction position verification of lung tumors with an EPID in cine mode
    Ionascu, D.
    Park, S.
    Killoran, J.
    Allen, A.
    Berbeco, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2528 - 2528
  • [9] An Intra-fraction markerless daily lung tumor localization algorithm for EPID images
    Rozario, Timothy
    Bereg, Sergey
    Mao, Weihua
    8TH ACM INTERNATIONAL CONFERENCE ON PERVASIVE TECHNOLOGIES RELATED TO ASSISTIVE ENVIRONMENTS (PETRA 2015), 2015,
  • [10] Intra-Fraction Motion Characterization for Early Stage Rectal Cancer Using Cine-MRI
    Kleijnen, J.
    Asselen, B.
    Burbach, M.
    Intven, M.
    Reerink, O.
    Philippens, M.
    Lagendijk, J.
    Raaymakers, B.
    MEDICAL PHYSICS, 2014, 41 (06) : 537 - 537