Sensitivity of screening mammography by density and texture: a cohort study from a population-based screening program in Denmark

被引:52
|
作者
von Euler-Chelpin, My [1 ]
Lillholm, Martin [2 ,3 ]
Vejborg, Ilse [4 ]
Nielsen, Mads [2 ,3 ]
Lynge, Elsebeth [5 ]
机构
[1] Univ Copenhagen, Dept Publ Hlth, Oster Farimagsgade 5, DK-1014 Copenhagen K, Denmark
[2] Biomediq, Fruebjergvej 3, DK-2100 Copenhagen O, Denmark
[3] Univ Copenhagen, Dept Comp Sci, Univ Pk 5, DK-2100 Copenhagen O, Denmark
[4] Univ Hosp Copenhagen, Rigshosp, Ctr Diagnost Imaging, Dept Radiol, Blegdamsvej 9, DK-2100 Copenhagen O, Denmark
[5] Univ Copenhagen, Nykobing Falster Hosp, Ejegodsvej 63, DK-4800 Nykobing, Denmark
关键词
Mammography; Mammographic density; BI-RADS; Parenchymal texture marker; Sensitivity; BREAST; LEGISLATION; CANCER; RISK;
D O I
10.1186/s13058-019-1203-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Screening mammography works better in fatty than in dense breast tissue. Computerized assessment of parenchymal texture is a non-subjective method to obtain a refined description of breast tissue, potentially valuable in addition to breast density scoring for the identification of women in need of supplementary imaging. We studied the sensitivity of screening mammography by a combination of radiologist-assessed Breast Imaging Reporting and Data System (BI-RADS) density score and computer-assessed parenchymal texture marker, mammography texture resemblance (MTR), in a population-based screening program. Methods Breast density was coded according to the fourth edition of the BI-RADS density code, and MTR marker was divided into quartiles from 1 to 4. Screening data were followed up for the identification of screen-detected and interval cancers. We calculated sensitivity and specificity with 95% confidence intervals (CI) by BI-RADS density score, MTR marker, and combination hereof. Results Density and texture were strongly correlated, but the combination led to the identification of subgroups with different sensitivity. Sensitivity was high, about 80%, in women with BI-RADS density score 1 and MTR markers 1 or 2. Sensitivity was low, 67%, in women with BI-RADS density score 2 and MTR marker 4. For women with BI-RADS density scores 3 and 4, the already low sensitivity was further decreased for women with MTR marker 4. Specificity was 97-99% in all subgroups. Conclusion Our study showed that women with low density constituted a heterogenous group. Classifying women for extra imaging based on density only might be a too crude approach. Screening sensitivity was systematically high in women with fatty and homogenous breast tissue.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Sensitivity of screening mammography by density and texture: a cohort study from a population-based screening program in Denmark
    My von Euler-Chelpin
    Martin Lillholm
    Ilse Vejborg
    Mads Nielsen
    Elsebeth Lynge
    [J]. Breast Cancer Research, 21
  • [2] Sensitivity of screening mammography by density and texture: A cohort study from a population based screening programme in Denmark
    von Euler-Chelpin, My
    [J]. CANCER RESEARCH, 2020, 80 (04)
  • [3] Overdiagnosis in screening mammography in Denmark: population based cohort study
    Njor, Sisse Helle
    Olsen, Anne Helene
    Blichert-Toft, Mogens
    Schwartz, Walter
    Vejborg, Ilse
    Lynge, Elsebeth
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 2013, 346
  • [4] Combined screening with mammography and ultrasound in a population-based screening program
    Buchberger, Wolfgang
    Geiger-Gritsch, Sabine
    Knapp, Rudolf
    Gautsch, Kurt
    Oberaigner, Willi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 24 - 29
  • [5] A POPULATION-BASED SCREENING MAMMOGRAPHY PROGRAM IN SASKATCHEWAN
    EDOUARD, L
    EBERTS, L
    BALDWIN, J
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 1994, 84 (06) : 1030 - 1031
  • [6] Psychosocial factors and attendance at a population-based mammography screening program in a cohort of Swedish women
    Lagerlund, Magdalena
    Sontrop, Jessica M.
    Zackrisson, Sophia
    [J]. BMC WOMENS HEALTH, 2014, 14
  • [7] Psychosocial factors and attendance at a population-based mammography screening program in a cohort of Swedish women
    Magdalena Lagerlund
    Jessica M Sontrop
    Sophia Zackrisson
    [J]. BMC Women's Health, 14
  • [8] Impact of transition from analog screening mammography to digital screening mammography on screening outcome in The Netherlands: a population-based study
    Nederend, J.
    Duijm, L. E. M.
    Louwman, M. W. J.
    Groenewoud, J. H.
    Donkers-van Rossum, A. B.
    Voogd, A. C.
    [J]. ANNALS OF ONCOLOGY, 2012, 23 (12) : 3098 - 3103
  • [9] Volume of screening mammography and performance in the Quebec population-based Breast Cancer Screening Program
    Théberge, I
    Hébert-Croteau, N
    Langlois, A
    Major, D
    Brisson, J
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2005, 172 (02) : 195 - 199
  • [10] Breast cancer risk predictions by birth cohort and ethnicity in a population-based screening mammography program
    Epp, Joyce
    Rajapakshe, Rasika
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1136):