Volume of screening mammography and performance in the Quebec population-based Breast Cancer Screening Program

被引:31
|
作者
Théberge, I
Hébert-Croteau, N
Langlois, A
Major, D
Brisson, J
机构
[1] Inst Natl Sante Publ Quebec, Direct Syst Soins & Serv, Ste Foy, PQ G1V 5B3, Canada
[2] Hop Charles LeMoyne, Ctr Rech, Greenfield Pk, PQ, Canada
[3] Univ Quebec, Ctr Hosp Affilie, Hop St Sacrement, Unite Rech Sante Populat, Quebec City, PQ, Canada
关键词
D O I
10.1503/cmaj.1040485
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: In the Quebec Breast Cancer Screening Program ( Programme quebecois de depistage du cancer du sein [PQDCS]), radiologists' and facilities' volumes of screening mammography vary considerably. We examined the relation of screening-mammography volume to rates of breast cancer detection and false-positive readings in the PQDCS. Methods: The study population included 307 314 asymptomatic women aged 50 - 69 years screened during 1998 - 2000. Breast cancer detection rates were analyzed by comparing all women with screening-detected breast cancer ( n = 1709) and a 10% random sample of those without ( n = 30 560). False-positive rates were analyzed by comparing the 3159 women with false-positive readings and the 27 401 others in the 10% random sample. Characteristics of participants, radiologists and facilities were obtained from the PQDCS information system. Data were analyzed by means of logistic regression. Results: The rate of breast cancer detection appeared to be unrelated to the radiologist's screening-mammography volume but increased with the facility's screening-mammography volume. The breast cancer detection rate ratio for facilities performing 4000 or more screenings per year, compared with those performing fewer than 2000, was 1.28 (95% confidence interval [CI] 1.07 - 1.52). In contrast, the frequency of false-positive readings was unrelated to the facility's screening volume but was inversely related to the radiologist's screening volume: the rate ratio for readers of 1500 or more screenings per year compared with those reading fewer than 250 was 0.53 ( 95% CI 0.35 - 0.79). Interpretation: Radiologists' and facilities' caseloads showed independent and complementary associations with performance of screening mammography in the PQDCS. Radiologists who worked in larger facilities and read more screening mammograms had higher breast cancer detection rates while maintaining lower false-positive rates.
引用
收藏
页码:195 / 199
页数:5
相关论文
共 50 条
  • [1] Breast cancer subtype and screening sensitivity in the Quebec Mammography Screening Program
    Perron, Linda
    Chang, Sue-Ling
    Daigle, Jean-Marc
    Vandal, Nathalie
    Theberge, Isabelle
    Diorio, Caroline
    Lemieux, Julie
    Pelletier, Eric
    Brisson, Jacques
    [J]. JOURNAL OF MEDICAL SCREENING, 2019, 26 (03) : 154 - 161
  • [2] Breast cancer survival by age in a Swedish population-based mammography screening program
    Thurfjell, EL
    Lindgren, A
    [J]. RADIOLOGY, 1996, 201 : 432 - 432
  • [3] Utilization of screening mammography as a preventive practice prior to initiating a population-based breast cancer screening program
    Segura, JM
    Castells, X
    Casamitjana, M
    Macià, F
    Ferrer, F
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2000, 53 (06) : 595 - 603
  • [4] Combined screening with mammography and ultrasound in a population-based screening program
    Buchberger, Wolfgang
    Geiger-Gritsch, Sabine
    Knapp, Rudolf
    Gautsch, Kurt
    Oberaigner, Willi
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 : 24 - 29
  • [5] COST-EFFECTIVENESS OF DIGITAL MAMMOGRAPHY IN A BREAST CANCER POPULATION-BASED SCREENING PROGRAM
    Comas, M.
    Arrospide, A.
    Mar, J.
    Roman, R.
    Sala, M.
    Hernandez, C.
    Castells, X.
    [J]. VALUE IN HEALTH, 2010, 13 (07) : A270 - A270
  • [6] A POPULATION-BASED SCREENING MAMMOGRAPHY PROGRAM IN SASKATCHEWAN
    EDOUARD, L
    EBERTS, L
    BALDWIN, J
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH, 1994, 84 (06) : 1030 - 1031
  • [7] Breast Cancer Screening Results 5 Years after Introduction of Digital Mammography in a Population-based Screening Program
    Karssemeijer, Nico
    Bluekens, Adriana M.
    Beijerinck, David
    Deurenberg, Jan J.
    Beekman, Matthijs
    Visser, Roelant
    van Engen, Ruben
    Bartels-Kortland, Annemieke
    Broeders, Mireille J.
    [J]. RADIOLOGY, 2009, 253 (02) : 353 - 358
  • [8] Implementation of Digital Mammography in a Population-based Breast Cancer Screening Program: Effect of Screening Round on Recall Rate and Cancer Detection
    Sala, Maria
    Comas, Merce
    Macia, Francesc
    Martinez, Juan
    Casamitjana, Montserrat
    Castells, Xavier
    [J]. RADIOLOGY, 2009, 252 (01) : 31 - 39
  • [9] Incidence of breast cancer and estimates of overdiagnosis after the initiation of a population-based mammography screening program
    Coldman, Andrew
    Phillips, Norm
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2013, 185 (10) : E492 - E498
  • [10] Breast cancer risk predictions by birth cohort and ethnicity in a population-based screening mammography program
    Epp, Joyce
    Rajapakshe, Rasika
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2022, 95 (1136):