Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

被引:7
|
作者
Kim, Do-Yoon [1 ]
Lim, Bum-Soon [2 ]
Baek, Seung-Hak [1 ,3 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Biomat Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dent Res Inst, Seoul, South Korea
关键词
Frictional force; Tooth displacement; initial leveling and alignment; Lingual bracket; STICK-SLIP PHENOMENON; ORTHODONTIC APPLIANCES; INTERBRACKET DISTANCE; RESISTANCE; ARCHWIRES; VIBRATION; DESIGNS; MODELS; TRIAL; FORCE;
D O I
10.4041/kjod.2016.46.2.87
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXL1); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at 36.5 degrees C. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the ln-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXL1. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXL1 in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 33 条
  • [31] Comparison of Surface Topography Changes from Conventional Metal Brackets and Self-Ligating Metal Brackets after Immersion in Three Different Mouthwashes using Atomic Force Microscopy: An in vitro Study
    Thulasiram, Sakthivel Ram S. R.
    Chandrasekharan, Deepak
    Angrish, Nidhi
    Krithika, A.
    Praveen, Katepogu
    Deenadayalan, P.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S636 - S640
  • [32] Comparison of the friction forces delivered by different elastomeric patterns and metal ligature on conventional metal brackets with a NiTi arch wire versus a self-ligating system: An in vitro study
    Pieroni, Mateus
    Borges Ferraz Facury, Analia Gabriella
    Santamaria-Jr, Milton
    Correr, Americo Bortolazzo
    Correr-Sobrinho, Lourenco
    Vedovello Filho, Mario
    Costa, Ana Rosa
    Neves, Jose Guilherme
    INTERNATIONAL ORTHODONTICS, 2022, 20 (02)
  • [33] Comparative assessment of the rate of orthodontic tooth movement in adolescent patients undergoing treatment by first bicuspid extraction and en mass retraction, associated with low-frequency mechanical vibrations in passive self-ligating and conventional brackets: A randomized controlled trial
    Kumar, Vaibhav
    Batra, Puneet
    Sharma, Karan
    Raghavan, Sreevatsan
    Srivastava, Amit
    INTERNATIONAL ORTHODONTICS, 2020, 18 (04) : 696 - 705