Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

被引:7
|
作者
Kim, Do-Yoon [1 ]
Lim, Bum-Soon [2 ]
Baek, Seung-Hak [1 ,3 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, 101 Daehak Ro, Seoul 03080, South Korea
[2] Seoul Natl Univ, Sch Dent, Dept Biomat Sci, Seoul, South Korea
[3] Seoul Natl Univ, Dent Res Inst, Seoul, South Korea
关键词
Frictional force; Tooth displacement; initial leveling and alignment; Lingual bracket; STICK-SLIP PHENOMENON; ORTHODONTIC APPLIANCES; INTERBRACKET DISTANCE; RESISTANCE; ARCHWIRES; VIBRATION; DESIGNS; MODELS; TRIAL; FORCE;
D O I
10.4041/kjod.2016.46.2.87
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXL1); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at 36.5 degrees C. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the ln-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXL1. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXL1 in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.
引用
收藏
页码:87 / 95
页数:9
相关论文
共 33 条
  • [21] Leveling and alignment time and the periodontal status in patients with severe upper crowding treated by corticotomy-assisted self-ligating brackets in comparison with conventional or self-ligating brackets only: a 3-arm randomized controlled clinical trial
    Al-Ibrahim, Heba M.
    Hajeer, Mohammad Y.
    Alkhouri, Issam
    Zinah, Eiad
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (01) : 3 - 11
  • [22] Comparison of frictional coefficient and surface roughness between three different active self-ligating brackets: An experimental in vitro study
    Syahdinda, Meralda R.
    Lucynda, Lucky
    Triwardhani, Ari
    Hamid, Thalca
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2020, 12 (06): : 551 - 555
  • [23] Effect of self-ligating bracket type and vibration on frictional force and stick-slip phenomenon in diverse tooth displacement conditions: an in vitro mechanical analysis
    Seo, Yu-Jin
    Lim, Bum-Soon
    Park, Young Guk
    Yang, Il-Hyung
    Ahn, Seok-Joon
    Kim, Tae-Woo
    Baek, Seung-Hak
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (05) : 474 - 480
  • [24] A comparative study of frictional force in self-ligating brackets according to the bracket-archwire angulation, bracket material, and wire type
    Lee, Souk Min
    Hwang, Chung-Ju
    KOREAN JOURNAL OF ORTHODONTICS, 2015, 45 (01) : 13 - 19
  • [25] Friction properties according to vertical and horizontal tooth displacement and bracket type during initial leveling and alignment
    Heo, Wook
    Baek, Seung-Hak
    ANGLE ORTHODONTIST, 2011, 81 (04) : 653 - 661
  • [26] A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types of pre-adjusted edgewise brackets tied with elastomeric ligatures
    Thomas, S
    Sherriff, M
    Birnie, D
    EUROPEAN JOURNAL OF ORTHODONTICS, 1998, 20 (05) : 589 - 596
  • [27] Effect of tooth displacement and vibration on frictional force and stick-slip phenomenon in conventional brackets: a preliminary in vitro mechanical analysis
    Seo, Yu-Jin
    Lim, Bum-Soon
    Park, Young Guk
    Yang, Il-Hyung
    Ahn, Seok-Joon
    Kim, Tae-Woo
    Baek, Seung-Hak
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (02) : 158 - 163
  • [28] A prospective randomized split-mouth study on pain experience during chairside archwire manipulation in self-ligating and conventional brackets
    Bertl, Michael H.
    Onodera, Kanji
    Celar, Ales G.
    ANGLE ORTHODONTIST, 2013, 83 (02) : 292 - 297
  • [29] The comparison of frictional resistance in titanium, self-ligating stainless steel, and stainless steel brackets using stainless steel and TMA archwires: An in vitro study
    Khalid, Syed Altaf
    Kumar, Vadivel
    Jayaram, Prithviraj
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2012, 4 (06): : S203 - S211
  • [30] Assessment of Enamel Surface Using Scanning Electron Microscope After Debonding Conventional and Self-Ligating Metal and Ceramic Brackets: An In Vitro Study
    Lishna, Karalikkattil T.
    Shaloob, Muhamed
    Antony, Vincy
    Roshan, Gazanafer
    Parayaruthottam, Prathapan
    Nayaz, V. P. Mohammed
    Raheesh, Muhammed
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2024, 16 (03): : 214 - 222